The present study aims to develop a selective molecularly imprinted polymer (MIP) layer combined with quartz crystal microbalance sensor for the detection of 3- Carene, a significant aroma compound of mango. The proposed sensor is prepared from the co-polymer of methacrylic acid and divinylbenzene and it is imprinted with 3- Carene. The MIP template was synthesized and deposited onto Quartz Crystal Microbalance (QCM) platform by proper functionalizing the gold electrode using 2-propene 1- thiol. The developed MIP material is characterized by fourier transform infra-red, scanning electron microscope and atomic force microscope techniques. The sensor offers very good selectivity and sensitivity (1-1000ppm) of 0.11 Hz/ppm to 3- Carene from its structural analogies. The LOD and the LOQ of the sensor are found to be 0.8 ppm and 1.4 ppm, respectively. The performance of the sensor offers satisfactory reproducibility and repeatability to 3-Carene. Moreover, the response of the sensor has been correlated to the standard gas- chromatography-mass spectrometry (GC-MS) data to detect 3- Carene in Langda and Chausa mango.
In this paper, a molecular imprinted poly β cyclodextrin embedded graphite (MIP- β-CD@G) electrode is reported, which has been developed for electrochemical determination of capsaicin (CP). MIP- β-CD@G has been synthesized by copolymerization of β-cyclodextrin ( β-CD), ethylene glycol dimethacrylate (EGDMA) along with graphite powder and CP molecule in presence of benzoyl peroxide (BP). In the ultra violet - visible (UV-Vis.) spectrum, the disappearance of absorption peak of CP confirms the successful leaching out of the target molecule upon its extraction during the formation of MIP. Cyclic voltammetry (CV) responses revealed that MIP- β-CD@G electrode showed remarkable increase in peak current towards electro-oxidation of CP as compared to non-imprinted polymer (NIP) electrode. Under optimized experimental condition, MIP- β-CD@G maintained linear relationship between concentration of CP vs. peak current in the range of 0.1 μM - 1.0 μM and 1.0 μM - 180 μM for the β cyclodextrin embedded graphite electrode. The lower limit of detection (LOD) towards CP was found to be 0.007 μM (S/N = 3) with the fabricated electrode. The practical applicability of MIP- β-CD@G electrode was tested with green chili pepper extracts which yielded satisfactory results.
In this paper, development of a polyacrylonitrile molecularly imprinted polymer embedded graphite (PANMIP/ G) electrode is described and its use as a sensitive and selective electrochemical sensor for determination of Eugenol (EU) in various food ingredients. The pure polyacrylonitrile is found to be the most efficient polymer material in comparison with other compositions involving acrylo-acid, acrylamide, acrylate esters and their mixtures. The PAN-MIP/G electrode shows three different linear determination ranges: 0.0005-1.0μM, 1-50 μM and 50-160 μM with lowest detection limit of 0.0004 lM. PAN-MIP/G is characterized by field emission scanning electron microscope (FESEM) and fourier transform infra-red (FTIR) spectroscopy. The effect of variables such as electrolytes, pH and scan rate are optimized to get highest sensitivity. The PAN-MIP/G electrode shows good repeatability, reproducibility and excellent sensitivity towards EU. The effects of common interferences on the EU peak current are studied. Furthermore, the developed electrode is successfully applied for the determination of EU in curry powder, clove powder and capsule samples.
Artificially ripened mango is harmful for health due to generation of some toxic chemicals. An electrochemical biosensor based on a molecularly imprinted polymer (MIP) was prepared for identifying artificial ripening of mango through its biomarker Furaneol (FU). Furaneol is found disappear on exposure to acetylene during artificial ripening. Methacrylic acid (MAA) copolymerized with ethylene glycol dimethacrylate (EGDMA) was utilized in developing FU imprinted sensor. The response characteristics of the sensor were evaluated by measuring the current response to FU with sensitivity factor of 0.017 A/M with wide detection range. The sensor response found to be highly selective to FU irrespective of other interfering analytes. The limit of detection of the graphite based poly-MAA imprinted Furaneol (PMAAFU/G) sensor is 11 nM with wide linear detection range of 0.5 μM – 500 μM. Further the sensor was applied to natural and acetylene treated mangoes and compared with GC-MS data. The sensor is very successful with high recovery and sensitivity.