Andreas Tsiamis

Dr. Andreas Tsiamis

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
FRFrancesco Mattioli Della Rocca
Francesco Mattioli Della Rocca
HMHanning Mai
Hanning Mai
SHSam W. Hutchings
Sam W. Hutchings
TATarek Al Abbas
Tarek Al Abbas
KBKasper Buckbee
Kasper Buckbee
RHRobert Henderson
Robert Henderson
A 128 × 128 single-photon avalanche diode (SPAD) motion detection-triggered time-of-flight (ToF) sensor is implemented in STMicroelectronics 40 nm CMOS SPAD foundry process. The sensor combines vision and ToF ranging functions to acquire depth frames only when inter-frame intensity changes are detected. The 40 μm × 20 μm pixels integrate two 16-bit time-gated counters to acquire ToF histograms and repurpose them to compare two vision frames without the requirement for additional out-of-pixel frame memory resources. An embedded column-parallel ToF and vision processor performs on-chip vision frame comparison and binary frame output compression as well as controlling the time-resolved histogram sampling. The sensor achieves a maximum 32.5 kframes/s in vision modality and 500 frames/s in motion detection-triggered ToF over a measured 3.5 m distance with 1.5 cm accuracy. The vision function reduces the sensor power consumption by 70% over continuous ToF operation and allows the sensor to gate the ToF laser emitter to reduce the system power when no motion activity is observed.

28 December 2014 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
PCP. J. Connolly
P. J. Connolly
GMG. B. McFiggans
G. B. McFiggans
RWR. Wood
R. Wood
ATAndreas Tsiamis
Andreas Tsiamis
We investigate the sensitivity of marine cloud brightening to the properties of the added salt particle distribution using a cloud parcel model, with an aim to address the question of, ‘what is the most efficient particle size distribution that will produce a desired cooling effect?’ We examine the effect that altering the aerosol particle size distribution has on the activation and growth of drops, i.e. the Twomey effect alone, and do not consider macrophysical cloud responses that may enhance or mitigate the Twomey effect. For all four spray generation methods considered, Rayleigh jet ; Taylor cone jet ; supercritical fluid ; and effervescent spray , salt particles within the median dry diameter range D m =30–100 nm are the most effective range of sizes. The Rayleigh jet method is also the most energy efficient overall. We also find that care needs to be taken when using droplet activation parametrizations: for the concentrations considered, Aitken particles do not result in a decrease in the total albedo, as was found in a recent study, and such findings are likely to be a result of the parametrizations' inability to simulate the effect of swollen aerosol particles. Our findings suggest that interstitial aerosol particles play a role in controlling the albedo rather than just the activated cloud drops, which is an effect that the parametrization methods do not consider.

1 December 2020 in Sensing and Bio-Sensing Research
Verified
Journal Article
Open access
JMJamie Marland
Jamie Marland
MGMark E. Gray
Mark E. Gray
CDCamelia Dunare
Camelia Dunare
EBEwen Blair
Ewen Blair
ATAndreas Tsiamis
Andreas Tsiamis
AMAlan F. Murray
Alan F. Murray

1 February 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
EGEva González-Fernández
Eva González-Fernández
MSMatteo Staderini
Matteo Staderini
JMJamie R.K. Marland
Jamie R.K. Marland
Mark GrayMark Gray
Mark Gray
AUAhmet Uçar
Ahmet Uçar
AMAlan F. Murray
Alan F. Murray

27 October 2018 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Open access
PDF file
Mark GrayMark Gray
Mark Gray
JMJames Meehan
James Meehan
EBEwen Blair
Ewen Blair
CWCarol Ward
Carol Ward
SLSimon P. Langdon
Simon P. Langdon
DADavid Argyle
David Argyle
Real‐time monitoring of tumor microenvironment parameters using an implanted biosensor could provide valuable information on the dynamic nature of a tumor's biology and its response to treatment. However, following implantation biosensors may lose functionality due to biofouling caused by the foreign body response (FBR). This study developed a novel tumor xenograft model to evaluate the potential of six biomaterials (silicon dioxide, silicon nitride, Parylene‐C, Nafion, biocompatible EPOTEK epoxy resin, and platinum) to trigger a FBR when implanted into a solid tumor. Biomaterials were chosen based on their use in the construction of a novel biosensor, designed to measure spatial and temporal changes in intra‐tumoral O2, and pH. None of the biomaterials had any detrimental effect on tumor growth or body weight of the murine host. Immunohistochemistry showed no significant changes in tumor necrosis, hypoxic cell number, proliferation, apoptosis, immune cell infiltration, or collagen deposition. The absence of biofouling supports the use of these materials in biosensors; future investigations in preclinical cancer models are required, with a view to eventual applications in humans. To our knowledge this is the first documented investigation of the effects of modern biomaterials, used in the production of implantable sensors, on tumor tissue after implantation. © 2018 The Authors.Journal of Biomedical Materials Research Part B: Applied Biomaterialspublished by Wiley Periodicals, Inc. J Biomed Mater Res Part B, 2018. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1620–1633, 2019.

1 August 2019 in American Journal of Physiology-Gastrointestinal and Liver Physiology
Verified
Journal Article
Open access
PDF file
Mark GrayMark Gray
Mark Gray
JMJamie Marland
Jamie Marland
CDCamelia Dunare
Camelia Dunare
EBEwen Blair
Ewen Blair
JMJames Meehan
James Meehan
MPMark Potter
Mark Potter
Recent advances in the fields of electronics and microfabrication techniques have led to the development of implantable medical devices for use within the field of precision medicine. Monitoring visceral surface tissue O2 tension ([ ]) by means of an implantable sensor is potentially useful in many clinical situations, including the perioperative management of patients undergoing intestinal resection and anastomosis. This concept could provide a means by which treatment could be tailored to individual patients. This study describes the in vivo validation of a novel, miniaturized electrochemical O2 sensor to provide real-time data on intestinal [ ]. A single O2 sensor was placed onto the serosal surface of the small intestine of anesthetized rats that were exposed to ischemic (superior mesenteric artery occlusion) and hypoxemic (alterations in inspired fractional O2 concentrations) insults. Control experiments demonstrated that the sensors can function and remain stable in an in vivo environment. Intestinal [ ] decreased following superior mesenteric artery occlusion and with reductions in inspired O2 concentrations. These results were reversible after reinstating blood flow or by increasing inspired O2 concentrations. We have successfully developed an anesthetized rat intestinal ischemic and hypoxic model for validation of a miniaturized O2 sensor to provide real-time measurement of intestinal [ ]. Our results support further validation of the sensors in physiological conditions using a large animal model to provide evidence of their use in clinical applications where monitoring visceral surface tissue O2 tension is important. NEW & NOTEWORTHY This is the first report of real-time continuous measurements of intestinal oxygen tension made using a microfabricated O2 sensor. Using a developed rodent model, we have validated this sensor's ability to accurately measure dynamic and reversible changes in intestinal oxygenation that occur through ischemic and hypoxemic insults. Continuous monitoring of local intestinal oxygenation could have value in the postoperative monitoring of patients having undergone intestinal surgery.