Shuang Peng

Dr. Shuang Peng


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2017
Verified
Conference Paper
Open access
PDF file
SPShuang Peng
Shuang Peng
Link?ping University Electronic Press Conference Proceedings

25 April 2023 in Actuators
Verified
Journal Article
Open access
PDF file
SPShuang Peng
Shuang Peng
Valve switching is one of the most important power losses in digital hydraulics. In this paper, a dynamic Zero-Flowrate-Switching (ZFS) control method is developed for hydraulic/pneumatic systems. The proposed control strategy is to actively reduce the flowrate passing through the valve to zero before switching off the valve. To realize it, an accessory line, in which a RLC oscillator is applied to generate a sinusoidal flowrate, is allocated parallel to the main control line for flowrate regulation. The pressure, with high frequency and small amplitude wave outputs from a regular piston pump, is used to drive the RLC oscillator. To evaluate the performance of this strategy, mathematical models for switching power loss and pressure pulses are developed and characteristic analysis is conducted. The results show that the energy loss of the system when applying the dynamic ZFS controller is reduced to 16% compared to that of a normal hydraulic system without a dynamic ZFS controller; moreover, pressure pulses in a dynamic ZFS system are much more minor than those in a Hard-Switching system.

8 April 2024 in Actuators
Verified
Journal Article
Open access
PDF file
SPShuang Peng
Shuang Peng
FYFanglong Yin
Fanglong Yin
YHYong Hu
Yong Hu
Hydraulic switching actuators are high-efficiency, fast response, and low-cost solutions for hydraulic control systems. One of the challenging problems is throttling losses during valve transitions. Previously, the authors proposed a zero-flowrate switching method to reduce the throttling energy loss of the switching valve, where a hydraulic resonator is applied to make the flowrates through the lines approaching zero before the valves are switched off. The major challenge of this approach is fast switching valves whose transition times are less than 2 ms. In this paper, an improved zero-flowrate switching method is presented. It utilizes the capacity with independent inlet/outlet ports to regulate flowrates through the lines. Models of capacity applied in a simple line with different pressure signals are developed to explore characteristics of the capacity, based on which a complete actuation system is developed. In the complete model, resistance and inductance are optimized to achieve the desired flowrate response. The improved zero-flowrate switching method reduces throttling energy losses by 99.945% compared to a hard switching system. The simulation results demonstrated that the improved zero-flowrate switching method performs as expected in the design condition. A capacity with proper volume is able to regulate flowrates through all the lines to zero, with the help of appropriate resistance and inductance. Compared to the previous zero-flowrate switching method, the novel strategy allows slower switching valves applied in hydraulic actuation systems and achieves better efficiency performance. This research paves a new avenue for reducing throttling energy losses and improves system efficiency in hydraulic switching actuators, as well as most of the hydraulic switch-mode circuits.

8 March 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
SPShuang Peng
Shuang Peng
FYFanglong Yin
Fanglong Yin
YHYong Hu
Yong Hu
—Hydraulic switching actuators are high efficiency, fast response, and low cost solutions for hydraulic control systems. One of the challenging problems is throttling losses during valve transitions. Previously the authors proposed a zero-flowrate switching method to reduce throttling energy loss of the switching valve, where a hydraulic resonator is applied to make the flowrates through the lines approaching zero before the valves are switched off. The major challenge of this approach is fast switching valves whose transition times are less than 2 ms. In this paper, an improved zero-flowrate switching method is presented. It utilizes the capacity with independent inlet/outlet ports to regulate flowrates through the lines. Models of capacity applied in a simple line with different pressure signals are developed to explore characteristics of the capacity, based on which a complete actuation system is developed. In the complete model, resistance and inductance are optimized to achieve desired flowrate response. The improved zero-flowrate switching method reduces throttling energy losses by 99.945% compared to a hard switching system. The simulation results demonstrated that the improved zero-flowrate switching method performs as expected in the design condition. A capacity with proper volume is able to regulate flowrates through all the lines to zero, with the help of appropriate resistance and inductance. Compared to previous zero-flowrate switching method, the novel strategy allows slower switching valves applied in hydraulic actuation systems and achieves better efficiency performance. This research paves a new avenue for reducing throttling energy losses and improves system efficiency in hydraulic switching actuators, as well as most of the hydraulic switch-mode circuits.