Jenna L Mueller

Dr. Jenna L Mueller


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
MAMercy Nyamewaa Asiedu
Mercy Nyamewaa Asiedu
ASAnish Simhal
Anish Simhal
UCUsamah Chaudhary
Usamah Chaudhary
Jenna L MuellerJenna L Mueller
Jenna L Mueller
CLChristopher T. Lam
Christopher T. Lam
NRNirmala Ramanujam
Nirmala Ramanujam
Goal: In this work, we propose methods for (1) automatic feature extraction and classification for acetic acid and Lugol's iodine cervigrams and (2) methods for combining features/diagnosis of different contrasts in cervigrams for improved performance. Methods: We developed algorithms to pre-process pathology-labeled cervigrams and to extract simple but powerful color and textural-based features. The features were used to train a support vector machine model to classify cervigrams based on corresponding pathology for VIA, VILI, and combination of the two contrasts. Results: The proposed framework achieved a sensitivity, specificity, and accuracy of 81.3%, 78.6%, and 80.0%, respectively when used to distinguish cervical intraepithelial neoplasia (CIN+) relative to normal and benign tissues. This is superior to the average values achieved by expert physicians on the same data set for discriminating normal/benign from CIN+ (sensitivity=77%, specificity=51%, accuracy=63%). Conclusion: The results suggest that utilizing simple color- and textural-based features from VIA and VILI images may provide unbiased automation of cervigrams. Significance: This would enable automated expert-level diagnosis of cervical pre-cancer at the point-of-care.

12 June 2018 in BJOG: An International Journal of Obstetrics & Gynaecology
Verified
Journal Article
Closed access
PDF file
Jenna L MuellerJenna L Mueller
Jenna L Mueller
CLC T Lam
C T Lam
DDD Dahl
D Dahl
MAM N Asiedu
M N Asiedu
MKM S Krieger
M S Krieger
NRN Ramanujam
N Ramanujam

16 December 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
RMRobert Morhard
Robert Morhard
Jenna L MuellerJenna L Mueller
Jenna L Mueller
QTQishun Tang
Qishun Tang
CNCorrine Nief
Corrine Nief
ECErika Marie Chelales
Erika Marie Chelales
NRNimmi Ramanujam
Nimmi Ramanujam
Objective: Ethanol ablation, the injection of ethanol to induce necrosis, was originally used to treat hepatocellular carcinoma, with survival rates comparable to surgery. However, efficacy is limited due to leakage into surrounding tissue. To reduce leakage, we previously reported incorporating ethyl cellulose (EC) with ethanol as this mixture forms a gel when injected into tissue. To further develop EC-ethanol injection as an ablative therapy, the present study evaluates the extent to which salient injection parameters govern the injected fluid distribution. Methods: Utilizing ex vivo swine liver, injection parameters (infusion rate, EC%, infusion volume) were examined with fluorescein added to each solution. After injection, tissue samples were frozen, sectioned, and imaged. Results: While leakage was higher for ethanol and 3%EC-ethanol at a rate of 10 mL/hr compared to 1 mL/hr, leakage remained low for 6%EC-ethanol regardless of infusion rate. The impact of infusion volume and pressure were also investigated first in tissue-mimicking surrogates and then in tissue. Results indicated that there is a critical infusion pressure beyond which crack formation occurs leading to fluid leakage. At a rate of 10 mL/hr, a volume of 50 μL remained below the critical pressure. Conclusions: Although increasing the infusion rate increases stress on the tissue and the risk of crack formation, injections of 6%EC-ethanol were localized regardless of infusion rate. To further limit leakage, multiple low-volume infusions may be employed. Significance: These results, and the experimental framework developed to obtain them, can inform optimizing EC-ethanol to treat a range of medical conditions.

1 April 2017 in Journal of Lower Genital Tract Disease
Verified
Journal Article
Closed access
Jenna L MuellerJenna L Mueller
Jenna L Mueller
EAElizabeth Asma
Elizabeth Asma
CLChristopher T. Lam
Christopher T. Lam
MKMarlee S. Krieger
Marlee S. Krieger
JGJennifer E. Bs Gallagher
Jennifer E. Bs Gallagher
NRNimmi Ramanujam
Nimmi Ramanujam
Objective: Barriers to cervical cancer screening in low-resource settings include lack of accessible, high-quality services, high cost, and the need for multiple visits. To address these challenges, we developed a low-cost, intravaginal, optical cervical imaging device, the point-of-care tampon (POCkeT) colposcope and evaluated whether its performance is comparable with a standard-of-care colposcope. Materials and Methods: There were 2 protocols, which included 44 and 18 patients. For the first protocol, white-light cervical images were collected in vivo, blinded by device, and sent electronically to 8 physicians from high-, middle-, and low-income countries. For the second protocol, green-light images were also collected and sent electronically to the highest performing physician from the first protocol who has experience in both a high- and low-income country. For each image, physicians completed a survey assessing cervix characteristics and severity of precancerous lesions. Corresponding pathology was obtained for all image pairs. Results: For the first protocol, average percent agreement between devices was 70% across all physicians. The POCkeT and standard-of-care colposcope images had 37% and 51% agreement with pathology for high-grade squamous intraepithelial lesions (HSILs), respectively. Investigation of HSIL POCkeT images revealed decreased visibility of vascularization and lack of contrast in lesion margins. After changes were made for the second protocol, the 2 devices achieved similar agreement to pathology for HSIL lesions (55%). Conclusions: Based on the exploratory study, physician interpretation of cervix images acquired using a portable, low-cost POCkeT colposcope was comparable to a standard-of-care colposcope.

18 June 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Jenna L MuellerJenna L Mueller
Jenna L Mueller
ZHZachary T. Harmany
Zachary T. Harmany
JMJeffrey K. Mito
Jeffrey K. Mito
SKStephanie A. Kennedy
Stephanie A. Kennedy
YKYongbaek Kim
Yongbaek Kim
NRNimmi Ramanujam
Nimmi Ramanujam
To develop a robust tool for quantitative in situ pathology that allows visualization of heterogeneous tissue morphology and segmentation and quantification of image features. Tissue excised from a genetically engineered mouse model of sarcoma was imaged using a subcellular resolution microendoscope after topical application of a fluorescent anatomical contrast agent: acriflavine. An algorithm based on sparse component analysis (SCA) and the circle transform (CT) was developed for image segmentation and quantification of distinct tissue types. The accuracy of our approach was quantified through simulations of tumor and muscle images. Specifically, tumor, muscle, and tumor+muscle tissue images were simulated because these tissue types were most commonly observed in sarcoma margins. Simulations were based on tissue characteristics observed in pathology slides. The potential clinical utility of our approach was evaluated by imaging excised margins and the tumor bed in a cohort of mice after surgical resection of sarcoma. Simulation experiments revealed that SCA+CT achieved the lowest errors for larger nuclear sizes and for higher contrast ratios (nuclei intensity/background intensity). For imaging of tumor margins, SCA+CT effectively isolated nuclei from tumor, muscle, adipose, and tumor+muscle tissue types. Differences in density were correctly identified with SCA+CT in a cohort of ex vivo and in vivo images, thus illustrating the diagnostic potential of our approach. The combination of a subcellular-resolution microendoscope, acriflavine staining, and SCA+CT can be used to accurately isolate nuclei and quantify their density in anatomical images of heterogeneous tissue.

22 April 2016 in Journal of Cancer Research and Clinical Oncology
Verified
Journal Article
Closed access
PDF file
Jenna L MuellerJenna L Mueller
Jenna L Mueller
JGJennifer E. Gallagher
Jennifer E. Gallagher
RCRhea Chitalia
Rhea Chitalia
MKMarlee Krieger
Marlee Krieger
AEAlaattin Erkanli
Alaattin Erkanli
NRNimmi Ramanujam
Nimmi Ramanujam