Yakubu OF Abdullahi Jarma

Dr. Yakubu OF Abdullahi Jarma

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2025 in Water Research
Verified
Journal Article
Open access
YCYoram Cohen
Yoram Cohen
MSMaria Soto
Maria Soto
NMNora Marki
Nora Marki
YJYakubu OF Abdullahi Jarma
Yakubu OF Abdullahi Jarma
MGMadelyn Glickfeld
Madelyn Glickfeld
THThomas Hendrickson
Thomas Hendrickson
Techno-economic analysis of distributed wellhead water treatment and desalination (DWTD) systems was carried out based on a three-year field study in three small, disadvantaged communities (DACs) to evaluate the reliability and affordability of upgrading their impaired well water. The local water supplies of the three study DACs, located in Salinas Valley, California, were contaminated with nitrate at levels (∼ 12-87 mg/L NO3--N) above the California maximum contaminant level (MCL) of 10 mg/L NO3--N, and had elevated water salinity (∼600-1,600 mg/L total dissolved solids(TDS)) above its secondary MCL (SMCL) of 500 mg/L TDS. Well water nitrate removal and salinity reduction were accomplished via reverse osmosis (RO) based DWTD systems that operated autonomously, supported by remote monitoring and supervisory cyberinfrastructure. Reliable DWTD operation provided treated water quality, with respect to nitrate and salinity, in the range of 0.5-6.3 mg/L NO3--N and 57-161 mg/L TDS, respectively, which were well below the respective MCL and SMCL. The levelized cost of water treatment was in the range of ∼$2/m3- $2.9/m3 which aligns with typical residential water costs in California and in the study region, and monthly residential water costs ($39-$74/residential unit/month) were also within the range in California. The study showcased the DWTD approach as a viable and potentially scalable solution for upgrading impaired local potable water supply of communities lacking centralized water delivery infrastructure. However, streamlined permitting processes and standardized regulatory frameworks are critical to promoting wider adoption and maximizing the socio-economic benefits of the DWT approach. Moreover, DACs are likely to require government subsidies in order to cover the CapEx of DWTD systems in addition to upgrade of site infrastructure.

1 December 2021 in TURKISH JOURNAL OF EARTH SCIENCES
Verified
Journal Article
Open access
MMMehmet Kamil Meri̇ç
Mehmet Kamil Meri̇ç
YKYasemin Senem Kukul
Yasemin Senem Kukul
EÖEmrah Özçakal
Emrah Özçakal
Tuba BarlasTuba Barlas
Tuba Barlas
HÇHakan Çakici
Hakan Çakici
ABAlper BABA
Alper BABA

19 March 2023 in Water
Verified
Journal Article
Open access
PDF file
IPİlker Parlar
İlker Parlar
YJYakubu OF Abdullahi Jarma
Yakubu OF Abdullahi Jarma
TPTaylan O. Pek
Taylan O. Pek
NKNALAN KABAY
NALAN KABAY
MKMehmet Kitis
Mehmet Kitis
MYMithat Yuksel
Mithat Yuksel
Membrane fouling and mineral scaling remain major drawbacks for MBR technology. Membrane fouling reduces the filtration ability in MBR systems by increasing transmembrane pressure (TMP) and thus increases the operational cost. This study focused on the application of commercially available antiscalant in a pilot MBR system and the effect of diffuser perforation diameter for the treatment of high mineral scaling propensity wastewater. Submerged flat sheet membranes (Kubota, nominal pore size: 0.4 µm) were used in the pilot-scale test unit operated in the wastewater treatment plant of ITOB Organized Industrial Zone, Izmir, Turkey. The commercially available antiscalants employed were coded AS-1 and AS-2 for antiscalant study. Long term effect of the two antiscalants employed was investigated under high mixed liquor suspended solid (MLSS) concentration (17–21 g/L) for two months of MBR operation. The effect of low MLSS concentration (10–13 g/L) was also studied without changing the concentration of antiscalant type and concentration. AS-1 was found to be more effective in terms of mineral scale control. The effect of diffuser perforation diameter (1, 3 and 5 mm) on mineral scaling minimization in MBR pilot system was also studied. The best performance with respect to membrane fouling control was found with an air diffuser having 3 mm of diffuser perforated diameter. Some quality analyses of the product water were also carried out to assess the effect of antiscalant addition on microbial activities in the MBR unit. The findings in this study reveal that the use of antiscalants has not affected biological treatment performance of MBR pilot system. The removal ranges obtained during all MBR studies were 98.47–99.9%, 84.62–99.4%, 89.5–98.5%, 86.90–99.9%, 67.01–99.2%, 75.03–93.9%, and 20.36–71.5% for total suspended solid (TSS), color, chemical oxygen demand (COD), NH4-N, PO4-P, NO2-N, and total nitrogen (TN) respectively.

13 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
OGOfer Guy
Ofer Guy
BCB. Cohen
B. Cohen
YJYakubu OF Abdullahi Jarma
Yakubu OF Abdullahi Jarma
YCYoram Cohen
Yoram Cohen
NLNaftali Lazarovitch
Naftali Lazarovitch
JGJack Gilron
Jack Gilron
As water scarcity increasingly constrains agricultural production, non-potable water sources such as brackish groundwater are being considered for irrigation, but elevated salinity limits their direct use for high-value, salt-sensitive crops. Brackish water can be upgraded via reverse osmosis (RO) which effectively reduces salinity but also eliminates divalent ions that are beneficial for plant growth. While divalent ions can be replenished in the RO permeate by blending with brackish groundwater this can reintroduce undesirable levels of sodium and chloride ions. To overcome the above deficiency, monovalent selective electrodialysis (MSED), which reduces chloride and sodium concentrations while preserving divalent ions, was employed to prepare irrigation water from brackish water. However, given that water treatment via MSED is currently significantly more expensive than RO, a two-pronged approach was adopted that combined blending of MSED diluate with RO permeate, along with optimization of MSED performance. The blending strategy reduced the degree of required monovalent ion removal via MSED which was further optimized by balancing monovalent ion selectivity and volumetric treatment capacity through operation at or near the sodium-defined limiting current (ilim). Also, active control of the electrical current as a constant fraction of the ion-specific limiting current (R=i/ ilim,Na) maximized Na⁺ and Cl⁻ removal relative to divalent ions. Improved performance of RO/MSED blends relative to RO/brackish water blends and RO treated water was demonstrated in irrigation experiments with lettuce and strawberry. RO/MSED blending achieved higher crop yields without a significant cost penalty relative to RO/brackish water blending with attendant environmental benefits.

30 June 2026 in International Journal of Pioneering Technology and Engineering
Verified
Journal Article
Open access
GUGökçe Uslu
Gökçe Uslu
ZTZahra Hajimohammadi Tabriz
Zahra Hajimohammadi Tabriz
HHHüseyin Utku Helvacı
Hüseyin Utku Helvacı
MMMousa Mohammadpourfard
Mousa Mohammadpourfard
YJYakubu OF Abdullahi Jarma
Yakubu OF Abdullahi Jarma
GÜLDEN GÖKCEN AKKURTGÜLDEN GÖKCEN AKKURT
GÜLDEN GÖKCEN AKKURT
The aim of this study is to design, model, and thermo-economically evaluate a PV-battery-grid integrated reverse osmosis desalination system for geothermal brine treatment in the Balcova Geothermal District Heating System, İzmir, Türkiye, with the objective of maximizing photovoltaic energy utilization and minimizing grid dependence. The system comprises PV panels, batteries, and the grid to supply electricity during the desalination process and it is modelled and simulated via TRNSYS software. A comprehensive thermo-economic modelling approach is employed to evaluate system performance under three solar-radiation scenarios, namely the low-radiation (LR), average-radiation (AR), and high-radiation (HR) scenarios. The findings indicate that the scenario with minimal radiation has the maximum net present value and the longest payback period. The scenario with the average radiation is identified as the most feasible investment, with a net present value of $52,218.7 and a payback period of 11.1 years. The cost of energy varies depending on the scenario, with the lowest radiation resulting in the lowest cost per kWh at $0.22/kWh. However, taking into account the payback period of 11.16 years and a net present value of $52,218.70, the average radiation scenario is the most viable investment. Overall, the findings reveal that the proposed system offers a sustainable and economical solution to water scarcity, with detailed energy, exergy, and economic analyses supplying vital information regarding system design and scalability.