Wangwang Tang

Dr. Wangwang Tang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2021 in Physical Review A
Verified
Journal Article
Closed access
PDF file
XGXu-xing Geng
Xu-xing Geng
GYGuoqing Yang
Guoqing Yang
PQPan-Li Qi
Pan-Li Qi
WTWangwang Tang
Wangwang Tang
SLShangqing Liang
Shangqing Liang
HGHuang Guangming
Huang Guangming
We have theoretically and experimentally investigated the laser-detected magnetic resonance induced by radio-frequency two-photon processes in Fg=4 of D1 line of cesium atoms. The effective Hamiltonian for the interaction between the two radio-frequency magnetic fields and sublevels at the ground state of Fg=4 is derived. By appropriately selecting the frequencies of the two radio-frequency fields, the Raman two-photon process and the cascade two-photon process can occur, which induce the magnetic resonance detected through laser transmission spectra. The theoretical calculation results fit well with the experimental data. Our results maybe apply for measuring the high bandwidth radio-frequency magnetic fields in space and studying the magnetic-induction tomography.

9 November 2022 in Electronics
Verified
Journal Article
Open access
PDF file
KJKai Jin
Kai Jin
XGXu-xing Geng
Xu-xing Geng
ZLZhi Liang
Zhi Liang
WTWangwang Tang
Wangwang Tang
JXJianfeng Xiao
Jianfeng Xiao
SLShangqing Liang
Shangqing Liang
With the demand for fast response of magnetic field measurement and the development of laser diode technology, self-oscillating laser-pumped atomic magnetometers have become a new development trend. In this work, we designed a portable self-oscillating VCSEL-pumped Cs atom magnetometer, including the probe (optical path) and circuits. The signal amplification and feedback loop of the magnetometer, VCSEL laser control unit, and atomic cell temperature control unit were realized. We tested the performance of the magnetometer in the metering station. Finally, The performance of the VCSEL-pumped magnetometer designed in this work was compared with that of a CS-3 lamp-pumped self-oscillating atomic magnetometer; their performance was found to be mostly in the same order of magnitude, while the power consumption of our magnetometer was 3 W less than that of the CS-3. This work represents an exploratory attempt to integrate and miniaturize a portable self-oscillating VCSEL-pumped Cs atomic magnetometer.

19 July 2022 in Laser & Photonics Reviews
Verified
Journal Article
Open access
XGXu-xing Geng
Xu-xing Geng
GYGuoqing Yang
Guoqing Yang
KJKai Jin
Kai Jin
WTWangwang Tang
Wangwang Tang
SWShao‐Ping Wu
Shao‐Ping Wu
GLGaoxiang Li
Gaoxiang Li
Periodically modulated systems with parity symmetry have been extensively investigated in recent years and exhibited various novel phenomena and potential applications in quantum technologies. In this study, a pump‐probe structure is used to observe the influence of generalized parity on the alignment spectra of magnetic resonance in a periodically biharmonic modulated warm atomic cesium ensemble. The alignment spectra are symmetric when the generalized parity of modulated Floquet atomic ensemble is present. The breaking of spectral symmetry is accompanied by the absence of generalized parity. The influence of generalized parity on atomic alignment polarization distribution is analyzed based on the perspective of the angular‐momentum probability surface. A necessary and sufficient condition for generalized parity to maintain spectral symmetry is verified experimentally and theoretically, providing a new perspective to investigative complex periodic modulation system. The results are universally applicable to atomic and solid‐state systems.

14 October 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
WTWangwang Tang
Wangwang Tang
HGHuang Guangming
Huang Guangming
GLGaoxiang Li
Gaoxiang Li
GYGuoqing Yang
Guoqing Yang
Magnetic target localization using the magnetic gradient tensor (MGT) plays a significant role in underwater localization. However, this method inherently has a localization dead zone, which presents challenges for real-world applications. This paper delves into the root cause of this dead zone, identifying the non-invertibility of the MGT when the magnetic moment vector is orthogonal to the position vector from the target to the observation point. To tackle this issue, a method based on the eigenvector constraints is proposed. By constructing an objective function with eigenvector constraints and leveraging the property that its gradient at the observation point is zero, we derive an equivalent expression for the inverse of MGT that always holds and further develop a dead-zone-free localization method. To validate the robustness and efficacy of the proposed localization method, a comparative analysis with other methods is conducted. Simulation results in a 10 m × 10 m area under Gaussian noise demonstrate the proposed method’s capability to eliminate the dead zone and achieve an average localization error of 0.032 m. Experimental results further demonstrate that the proposed method eliminates the localization dead zone and exhibits greater robustness than the dominant method in the normal region. In summation, this paper provides an effective method for eliminating localization dead zone, offering a more stable and reliable method for magnetic target localization in practice.

13 February 2026 in Electronics
Verified
Journal Article
Open access
PDF file
ZSZixuan Song
Zixuan Song
WTWangwang Tang
Wangwang Tang
WDWendi Deng
Wendi Deng
HWHongxia Wang
Hongxia Wang
HGHuang Guangming
Huang Guangming
ZMzhiyuan Ma
zhiyuan Ma
Reliability testing for Single Event Effects (SEEs) requires accurate localization of heavy-ion tracks from projection images. Conventional localization often relies on handcrafted features and geometric fitting, which is sensitive to noise and difficult to accelerate in hardware. This paper presents a lightweight detector based on YOLOv5n that treats charge tracks in Topmetal pixel sensor projections as distinct objects and directly regresses the track angle and intercept, along with bounding boxes, in a single forward pass. On a synthetic dataset, the model achieves a precision of 0.9626 and a recall of 0.9493, with line-parameter errors of 0.3930° in angle and 0.4842 pixels in intercept. On experimental krypton beam data, the detector reaches a precision of 0.92 and a recall of 0.96, with a position resolution of 52.05 μm. We further deploy the model on an Xilinx Alveo U200, achieving an average per-frame accelerator latency of 3.1 ms while preserving measurement quality. This approach enables accurate, online track localization for SEE monitoring on Field-Programmable Gate Array (FPGA) platforms.

14 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WTWangwang Tang
Wangwang Tang
HGHuang Guangming
Huang Guangming
GLGaoxiang Li
Gaoxiang Li
GYGuoqing Yang
Guoqing Yang
XGXu-xing Geng
Xu-xing Geng
Optically pumped magnetometers (OPM) are critical in magnetic field precision measurement applications. The core of OPM is to use the Proportion Integration Differentiation (PID) algorithm to maintain atoms in a magnetic resonance state. However, because the PID algorithm requires multiple iterations to stabilize the measurement results, the OPM cannot perform best when the magnetic field changes rapidly. To address this tackle, this paper proposes a magnetic field measurement method based on the multilayer perceptron (MLP) model. By performing frequency modulation and synchronous demodulation on the RF field, the first-, second-, and third-order derivative values of the magnetic resonance curve are obtained. Using the mapping relationship between the three magnetic resonance derivative values and the detuning frequency and the MLP nonlinear fitting capability, a customized MLP model for calculating the magnetic field intensity is trained. The experimental results indicate that the proposed method can directly measure the magnetic field through a single measurement, improving the response speed over the PID method. The broader range of the higher-order derivative enhances the ability to handle rapid changes in magnetic fields. The sensitivity of the proposed method is 13fT/√Hz. This research demonstrates the potential of integrating machine learning techniques with OPM for precision magnetic field measurement scenarios.