Ángel Javier Aguirre de Juana

Dr. Ángel Javier Aguirre de Juana

Universidad de Zaragoza, Zaragoza, Aragon, Spain
+1
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in CATENA
Verified
Journal Article
Closed access
DBDavid Badía
David Badía
CMClara Martí
Clara Martí
ÁJÁngel Javier Aguirre de Juana
Ángel Javier Aguirre de Juana
JAJavier M. Aznar
Javier M. Aznar
José A. González-PérezJosé A. González-Pérez
José A. González-Pérez
TETeresa Echeverría
Teresa Echeverría

1 November 2013 in Science of The Total Environment
Verified
Journal Article
Closed access
DBDavid Badía-Villas
David Badía-Villas
CMClara Martí
Clara Martí
ÁJÁngel Javier Aguirre de Juana
Ángel Javier Aguirre de Juana

7 June 2012 in Sensors
Verified
Journal Article
Open access
PDF file
FGF. Javier Garcia-Ramos
F. Javier Garcia-Ramos
MVMariano Vidal
Mariano Vidal
ABAntonio Boné
Antonio Boné
HMHugo Malon
Hugo Malon
ÁJÁngel Javier Aguirre de Juana
Ángel Javier Aguirre de Juana
The flow of air generated by a new design of air assisted sprayer equipped with two axial fans of reversed rotation was analyzed. For this goal, a 3D sonic anemometer has been used (accuracy: 1.5%; measurement range: 0 to 45 m/s). The study was divided into a static test and a dynamic test. During the static test, the air velocity in the working vicinity of the sprayer was measured considering the following machine configurations: (1) one activated fan regulated at three air flows (machine working as a traditional sprayer); (2) two activated fans regulated at three air flows for each fan. In the static test 72 measurement points were considered. The location of the measurement points was as follow: left and right sides of the sprayer; three sections of measurement (A, B and C); three measurement distances from the shaft of the machine (1.5 m, 2.5 m and 3.5 m); and four measurement heights (1 m, 2 m, 3 m and 4 m). The static test results have shown significant differences in the module and the vertical angle of the air velocity vector in function of the regulations of the sprayer. In the dynamic test, the air velocity was measured at 2.5 m from the axis of the sprayer considering four measurement heights (1 m, 2 m, 3 m and 4 m). In this test, the sprayer regulations were: one or two activated fans; one air flow for each fan; forward speed of 2.8 km/h. The use of one fan (back) or two fans (back and front) produced significant differences on the duration of the presence of wind in the measurement point and on the direction of the air velocity vector. The module of the air velocity vector was not affected by the number of activated fans.

1 January 2023 in Journal of Vegetation Science
Verified
Journal Article
Closed access
DGDaniel Gómez
Daniel Gómez
ÁJÁngel Javier Aguirre de Juana
Ángel Javier Aguirre de Juana
RSRafael Jiménez Sánchez
Rafael Jiménez Sánchez
CMCelia Manrique Magallón
Celia Manrique Magallón

13 February 2014 in Mycorrhiza
Verified
Journal Article
Closed access
PDF file
AAAntonio Andrés-Alpuente
Antonio Andrés-Alpuente
SSSergio Sánchez
Sergio Sánchez
MMMaría Martín
María Martín
ÁJÁngel Javier Aguirre de Juana
Ángel Javier Aguirre de Juana
JBJuan J. Barriuso
Juan J. Barriuso

1 September 2013 in CATENA
Verified
Journal Article
Closed access
DBD. Badía
D. Badía
ÁJÁngel Javier Aguirre de Juana
Ángel Javier Aguirre de Juana
CMC. Martí
C. Martí
MMM.A. Márquez
M.A. Márquez