Rui Huang

Dr. Rui Huang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2023 in Electronics
Verified
Journal Article
Open access
PDF file
RHRui Huang
Rui Huang
XXXiaojun Xue
Xiaojun Xue
RXRenjie Xiao
Renjie Xiao
FBFan Bu
Fan Bu
Objective. The wearable electrocardiogram (ECG) monitoring device is an effective tool for diagnosing intermittent heart diseases. However, the massive amount of ECG data increases power consumption during wireless transmission, thereby reducing the monitoring duration of the wearable device. Here, we presented a novel method to solve this problem. Method. To reduce the data size, we used a down-sampling operation to compress signals. Then, we designed a signal-referenced network to reconstruct the original signals from the compressed ones. We validated the proposed method on the China Physiological Signal Challenge 2018 database, used the root mean square error (RMSE) to evaluate the performance of the proposed network, and evaluated the effectiveness of the reconstructed signals via the F1-score of an ECG signal classifier. Main Result. The classifier used in this paper achieved an F1-score of 84% on 500 Hz signals reconstructed from 25 Hz, 89% from 50 Hz, 90% from 125 Hz, and 95% from 250 Hz. The RMSE of these four sampling rates was 0.10 mV, 0.08 mV, 0.05 mV, and 0.04 mV, respectively. Significance. The experimental result shows that the proposed network has a good performance when reconstructing signals. Furthermore, our method can remove the computational load of compressing signals from wearable devices.

13 December 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HZHuang Zhiguo
Huang Zhiguo
RHRui Huang
Rui Huang
XXXiaojun Xue
Xiaojun Xue
To determine the feasibility of observing high-orbit targets with a large aperture telescope, we created a simulation based on electronics to evaluate the signal-to-noise ratio (SNR) model for an infrared ground-based photoelectric system. Atmosphere transmission and sky background radiation data were obtained using MODTRAN software, then the SNRs of the high-orbit target (HOT) in different temperatures and orbit heights were calculated separately. The results showed that the observation of the HOT in a short band was possible, and the effect of short-wave was excellent at low temperatures. On the basis of this model, some space targets were observed by a K-band photoelectric telescope for verification and had constructive results. Thus, the model can be used as a basis for whether a HOT can be detected.