Edilausson Moreno Carvalho

Dr. Edilausson Moreno Carvalho

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Jose BauerJose Bauer
Jose Bauer
ASAllana Silva e Silva
Allana Silva e Silva
ECEdilausson Moreno Carvalho
Edilausson Moreno Carvalho
Paulo FerreiraPaulo Ferreira
Paulo Ferreira
Ceci Nunes CarvalhoCeci Nunes Carvalho
Ceci Nunes Carvalho
RCRicardo Marins Carvalho
Ricardo Marins Carvalho

1 February 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
KCKarina Kato Carneiro
Karina Kato Carneiro
TATaylan Pinheiro Araujo
Taylan Pinheiro Araujo
ECEdilausson Moreno Carvalho
Edilausson Moreno Carvalho
MMMarcia Margarete Meier
Marcia Margarete Meier
ATAuro Atsushi Tanaka
Auro Atsushi Tanaka
Jose BauerJose Bauer
Jose Bauer

11 April 2019 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
Ceci Nunes CarvalhoCeci Nunes Carvalho
Ceci Nunes Carvalho
MLMarcos Daniel Septímio Lanza
Marcos Daniel Septímio Lanza
LDLetícia Gomes Dourado
Letícia Gomes Dourado
ECEdilausson Moreno Carvalho
Edilausson Moreno Carvalho
Jose BauerJose Bauer
Jose Bauer
Objectives. This study evaluated the effect of air-drying time and light-curing time on the degree of conversion (DC) of three etch-and-rinse adhesive systems: ONE-STEP (OS) and ONE-STEP plus (OSP), Ambar (AMB), and two multimode adhesive systems: All-Bond Universal (ABU) and ScotchBond Universal (SBU) by Fourier transform infrared (FTIR) analysis. Materials and Methods. The DC of each adhesive system was analyzed with six experimental different protocols: (1) immediate light curing for 10 s without solvent volatilization; (2) 10 s solvent volatilization with air stream plus 10 s light curing; (3) 60 s solvent volatilization with air stream plus 10 s light curing; (4) immediate light curing for 20 s without solvent volatilization; (5) 10 s solvent volatilization with air stream plus 20 s light curing; and (6) 60 s solvent volatilization with air stream plus 20 s light curing. FTIR spectra were obtained, and the DC was calculated by comparing the ratio of aliphatic/aromatic double carbon bonds before and after light activation (Bluephase 20i). The DC means were analyzed by three-way analysis of variance (ANOVA) and post hoc Tukey tests (α = 0.05). Results. Three-way ANOVA showed statistically significant adhesive, air-drying, and light-cured time (p<0.001). In general, there was a trend of increased DC when the adhesives were dried and cured for longer times, but that was not observed for all the adhesives tested. The acetone-based adhesive systems require an air-drying prior to light activation. The light-curing time of 20 s increases the DC of all materials tested. Conclusion. The results suggested that the DC of the adhesive systems tested was material dependent. In general, the protocol with solvent evaporation for 10 seconds with air syringe plus 20 seconds of light curing finds the high values of DC.


1 June 2020 in International Journal of Adhesion and Adhesives
Verified
Journal Article
Closed access
MPMariana Almeida Mello Proença
Mariana Almeida Mello Proença
ECEdilausson Moreno Carvalho
Edilausson Moreno Carvalho
ASAllana Silva e Silva
Allana Silva e Silva
GRGeyse Adriana Corrêa Ribeiro
Geyse Adriana Corrêa Ribeiro
Paulo FerreiraPaulo Ferreira
Paulo Ferreira
Jose BauerJose Bauer
Jose Bauer

15 September 2019 in International Journal of Dentistry
Verified
Journal Article
Open access
GOGilliard Lima Oliveira
Gilliard Lima Oliveira
Ceci Nunes CarvalhoCeci Nunes Carvalho
Ceci Nunes Carvalho
ECEdilausson Moreno Carvalho
Edilausson Moreno Carvalho
Jose BauerJose Bauer
Jose Bauer
ALAdriana Mara Araújo Leal
Adriana Mara Araújo Leal
Objective. To evaluate the compressive strength and fluoride ion release of conventional and resin-modified glass ionomer cement mixing methods (hand mix and mechanical mix) compared to ready-to-use ones. Materials and Methods. Two conventional glass ionomer cements (GICs) (Fuji II and Fuji II Caps), two resin-modified GICs (Fuji II LC and Fuji II L Caps), and one ready-to-use GIC (Ionoseal, Voco) were used. For the compressive strength test, cylindrical specimens (6 mm × 4 mm) of each group were prepared. The test was performed in a universal testing machine (EMIC DL2000). For the fluoride release test, specimens were prepared in the form of discs and placed in deionized/distilled water, which were replaced daily for 15 days. The fluoride ion release readings were performed on an electrode (Orion 96-09) connected to a digital ion analyzer (Quimis 0400ISE). The compressive strength data were analyzed with one-way ANOVA, and the ion release data were submitted to repeated measures ANOVA (material vs. time) and Holm–Sidak post test (α = 5%). Results. The one-way ANOVA showed statistical difference between the tested materials (p<0.001). Ionoseal showed the highest values of compressive strength (p<0.001). Mechanical manipulation increased the compressive strength only for conventional GIC, and resin-modified GIC did not present any statistical difference. Conventional GIC (mechanical mix) showed higher fluoride release on first day than the other groups tested. Conclusion. There was influence of the mixing methods of the materials on the compressive strength and fluoride release pattern of the glass ionomer cements.