Honglue Tan

Dr. Honglue Tan

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
HTHonglue Tan
Honglue Tan
RMRui Ma
Rui Ma
CLChucheng Lin
Chucheng Lin
ZLZiwei Liu
Ziwei Liu
TTTingting Tang
Tingting Tang
Chitosan (CS) is a linear polysaccharide with good biodegradability, biocompatibility and antimicrobial activity, which makes it potentially useful for biomedical applications, including an antimicrobial agent either alone or blended with other polymers. However, the poor solubility of CS in most solvents at neutral or high pH substantially limits its use. Quaternary ammonium CS, which was prepared by introducing a quaternary ammonium group on a dissociative hydroxyl group or amino group of the CS, exhibited improved water solubility and stronger antibacterial activity relative to CS over an entire range of pH values; thus, this quaternary modification increases the potential biomedical applications of CS in the field of anti-infection. This review discusses the current findings on the antimicrobial properties of quaternized CS synthesized using different methods and the mechanisms of its antimicrobial actions. The potential antimicrobial applications in the orthopedic field and perspectives regarding future studies in this field are also considered.

1 October 2013 in Journal of Surgical Research
Verified
Journal Article
Closed access
XLXin Li
Xin Li
HGHao Guo
Hao Guo
QTQingzhong Tian
Qingzhong Tian
GZGang Zheng
Gang Zheng
YHYangchao Hu
Yangchao Hu
HTHonglue Tan
Honglue Tan

1 April 2014 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
SYShengbing Yang
Shengbing Yang
JWJing Wang
Jing Wang
LTLiangji Tang
Liangji Tang
HAHaiyong Ao
Haiyong Ao
HTHonglue Tan
Honglue Tan
CLChangsheng Liu
Changsheng Liu

26 December 2022 in Bone
Verified
Journal Article
Closed access
GCGuorui Cao
Guorui Cao
SZShaoyun Zhang
Shaoyun Zhang
YWYixuan Wang
Yixuan Wang
SQSongtao Quan
Songtao Quan
CYChen Yue
Chen Yue
HTHonglue Tan
Honglue Tan

3 March 2016 in Materials
Verified
Journal Article
Open access
PDF file
WLWentao Lin
Wentao Lin
YZYi-Yuan Zhang
Yi-Yuan Zhang
HTHonglue Tan
Honglue Tan
HAHaiyong Ao
Haiyong Ao
ZDZhao-Ling Duan
Zhao-Ling Duan
TTTingting Tang
Tingting Tang
Titania nanotube-based local drug delivery is an attractive strategy for combating implant-associated infection. In our previous study, we demonstrated that the gentamicin-loaded nanotubes could dramatically inhibit bacterial adhesion and biofilm formation on implant surfaces. Considering the overuse of antibiotics may lead to the evolution of antibiotic-resistant bacteria, we synthesized a new quaternized chitosan derivative (hydroxypropyltrimethyl ammonium chloride chitosan, HACC) with a 27% degree of substitution (DS; referred to as 27% HACC) that had a strong antibacterial activity and simultaneously good biocompatibility with osteogenic cells. Titania nanotubes with various diameters (80, 120, 160, and 200 nm) and 200 nm length were loaded with 2 mg of HACC using a lyophilization method and vacuum drying. Two standard strain, methicillin-resistant Staphylococcus aureus (American Type Culture Collection 43300) and Staphylococcus epidermidis (American Type Culture Collection 35984), and two clinical isolates, S. aureus 376 and S. epidermidis 389, were selected to investigate the bacterial adhesion at 6 h and biofilm formation at 24, 48, and 72 h on the HACC-loaded nanotubes (NT-H) using the spread plate method, confocal laser scanning microscopy (CLSM), and scanning electron microscopy (SEM). Smooth titanium (Smooth Ti) was also investigated and compared. We found that NT-H could significantly inhibit bacterial adhesion and biofilm formation on its surface compared with Smooth Ti, and the NT-H with 160 nm and 200 nm diameters had stronger antibacterial activity because of the extended HACC release time of NT-H with larger diameters. Therefore, NT-H can significantly improve the antibacterial ability of orthopedic implants and provide a promising strategy to prevent implant-associated infections.

1 October 2016 in Medicine
Verified
Journal Article
Open access
HTHonglue Tan
Honglue Tan
PDPengyi Dai
Pengyi Dai
YYYanhao Yuan
Yanhao Yuan
It was a retrospective case–control study. The aim of this study was to explore the clinical efficacy and complication of treatment using a modified Kirschner wire tension band (MKTB) or a cannulated screw tension band (CSTB) in transverse patellar fractures. In total, 55 patients with transverse patellar fractures were retrospectively reviewed and divided into 2 groups according to the surgical technique: 29 patients were in the MKTB group and 26 patients in the CSTB group. B[Latin Small Letter o with Caron]stman's clinical grading scale, including range of movement (ROM), pain, ability to work, atrophy of quadriceps femoris, assistance in walking, effusion, giving way, and stair-climbing, was used to evaluate the clinical results. Complications including painful hardware, implant loosening or breakage, and bone nonunion were also assessed. Both groups were evaluated at the final follow-up before removing implant in the MKTB group. The B[Latin Small Letter o with Caron]stman's score of ROM, pain, atrophy of quadriceps femoris, and effusion were all higher in the CSTB group than in the MKTB group (P < 0.05). Twelve patients in the MKTB group underwent implant removal, and the score of ROM, pain, and effusion were higher than before removing implant (P < 0.05), but there was no difference compared to the CSTB group (P > 0.05). Seventeen patients achieved excellent results, 9 had good results, and 3 reported fair results in the MKTB group; the CSTB group had excellent results in 22 patients and good results in 4 patients, showing a significant difference in the excellent rate between the 2 groups (P = 0.021). Total B[Latin Small Letter o with Caron]stman scores in the MKTB and CSTB groups (26.96 ± 4.47 and 29.42 ± 1.47, respectively) were significantly different (P = 0.01). Total scores in the MKTB group after removing implant were higher than those before removing implant (P = 0.001), and similar to those in the CSTB group (P = 0.224). Eleven patients in the MKTB group reported painful hardware, including 4 cases of implant loosening. CSTB achieves better clinical results than MKTB, meanwhile avoiding the problems of painful hardware and implant loosening. Functional limitation caused by hardware pain was commonly seen in the MKTB group, and removing implant after fracture healing improved knee function.