Pavel Pavlicek

Dr. Pavel Pavlicek


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
PPPavel Pavlicek
Pavel Pavlicek
VMVáclav Michálek
Václav Michálek

21 May 2008 in Applied Optics
Verified
Journal Article
Closed access
PDF file
PPPavel Pavlicek
Pavel Pavlicek
OHOndřej Hýbl
Ondřej Hýbl
White-light interferometry measuring an optically rough surface commonly does not resolve the lateral structure of the surface. This means that there are height differences within one resolution cell that exceed one-fourth of the wavelength of the light used. Thus the following questions arise: Which height is measured by white-light interferometry? How does the surface roughness affect the measurement uncertainty? The goal of the presented paper is to answer these questions by means of numerical simulations. Before the aforementioned questions can be answered, the distribution of the intensity of individual speckles, the influence of surface roughness, and the spectral width of the light source used are discussed.

1 February 2004 in Applied Optics
Verified
Journal Article
Closed access
PDF file
PPPavel Pavlicek
Pavel Pavlicek
JSJan Soubusta
Jan Soubusta
White-light interferometry is a well-established method for measuring the height profiles of samples with rough as well as with smooth surfaces. Because white-light interferometry uses broadband light sources, the problem of dispersion arises. Because the optical paths in the two interferometer arms cannot be balanced for all wavelengths, the white-light correlogram is distorted, which interferes with its evaluation. We investigate the influence of setup parameters on the shape of the correlogram. Calculated values are compared with experimental results.

1 April 2003 in Applied Optics
Verified
Journal Article
Closed access
PDF file
PPPavel Pavlicek
Pavel Pavlicek
JSJan Soubusta
Jan Soubusta
A great advantage of the white-light interferometry is that it can be used for profile measurement of objects with a rough surface. A speckle pattern that arises in the image plane allows one to observe the interference; however, this pattern is also the source of the measurement uncertainty. We derive the theoretical limits of the longitudinal uncertainty by virtue of the first-order statistics of the speckle pattern. It is shown that this uncertainty depends on the surface roughness of the measured object only; it does not depend on the setup parameters.

29 September 2009 in Applied Optics
Verified
Journal Article
Closed access
PDF file
PPPavel Pavlicek
Pavel Pavlicek
MHMarek Halouzka
Marek Halouzka
ZDZhihui Duan
Zhihui Duan
MTMitsuo Takeda
Mitsuo Takeda
The influence of tilted surfaces on the measurement of shape by spatial coherence profilometry is investigated. Based on theoretical analysis and experimental results, the systematic measurement error caused by surface tilt is determined. The systematic measurement error depends not only on the tilt angle but also on the parameters of the experimental setup. The theoretical analysis and the experiments show the similarities and differences between spatial coherence profilometry and white-light inter ferometry. We also suggest the conditions to obtain correct measurements by use of spatial coherence profilometry.

20 May 2005 in Applied Optics
Verified
Journal Article
Closed access
PDF file
PPPavel Pavlicek
Pavel Pavlicek
GHGerd Häusler
Gerd Häusler
We present a fiber-optical sensor for distance measurement of smooth and rough surfaces that is based on white-light interferometry; the sensor measures the distance from the sample surface to the sensor head. Because white light is used, the measurement is absolute. The measurement uncertainty depends not on the aperture of the optical system but only on the properties of the rough surface and is commonly ∼1 µm. The measurement range is approximately 1 mm. The sensor includes no mechanical moving parts; mechanical movement is replaced by the spectral decomposition of light at the interferometer output. The absence of mechanical moving parts enables a high measuring rate to be reached.