Luigi Tarallo

Prof. Dr. Luigi Tarallo

Orthopaedic Surgery and Traumatology Department, Azienda Ospedaliero-Universitaria Policlinico di Modena, University of Modena and Reggio Emilia, 41125 Modena, MO, Italy

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2005 in Plastic and Reconstructive Surgery
Verified
Journal Article
Closed access
RARoberto Adani
Roberto Adani
Luigi TaralloLuigi Tarallo
Luigi Tarallo
IMIgnazio Marcoccio
Ignazio Marcoccio
RCRiccardo Cipriani
Riccardo Cipriani
CGChiara Gelati
Chiara Gelati
MIMarco Innocenti
Marco Innocenti
Perforator flaps have been introduced for various kinds of reconstruction and resurfacing; in particular, the free thin anterolateral thigh flap is becoming one of the most preferred options for reconstruction of soft-tissue defects. Between 1999 and 2002, the authors used this flap as a free flap for nine cases for covering hand defects after burn, crushing injuries, or severe scar contracture release. There were eight men and one woman, the mean age of the patients was 31 years, and the size of the flaps ranged from 7 × 3.5 cm to 15 × 9 cm; thinning was performed in all flaps. All flaps survived completely, and the donor site was closed directly in seven cases; in two cases, the exposed muscle was covered with split-thickness skin graft. The anterolateral thigh flap was thin enough for defects on the dorsum and/or palm of the hand and for first web reconstruction after scar contracture release. It has many advantages in free flap surgery including a long pedicle with a suitable vessel diameter, and the donor-site morbidity is acceptable. The thin anterolateral thigh flap is a versatile soft-tissue flap that achieves good hand contour with low donor-site morbidity.

17 June 2014 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
Luigi TaralloLuigi Tarallo
Luigi Tarallo
RMRaffaele Mugnai
Raffaele Mugnai
RARoberto Adani
Roberto Adani
FCFrancesco Capra
Francesco Capra
FZFrancesco Zambianchi
Francesco Zambianchi
FCFabio Catani
Fabio Catani

1 January 2004 in Microsurgery
Verified
Journal Article
Closed access
PDF file
RARoberto Adani
Roberto Adani
LDLuca Delcroix
Luca Delcroix
MIMarco Innocenti
Marco Innocenti
IMIgnazio Marcoccio
Ignazio Marcoccio
Luigi TaralloLuigi Tarallo
Luigi Tarallo
MCMassimo Ceruso
Massimo Ceruso

8 July 2008 in La Chirurgia degli Organi di Movimento
Verified
Journal Article
Closed access
PDF file
RARoberto Adani
Roberto Adani
ABAlessio Baccarani
Alessio Baccarani
EGEnrico Guidi
Enrico Guidi
Luigi TaralloLuigi Tarallo
Luigi Tarallo

1 December 2013 in Journal of Orthopaedic Trauma
Verified
Journal Article
Open access
Luigi TaralloLuigi Tarallo
Luigi Tarallo
RMRaffaele Mugnai
Raffaele Mugnai
FZFrancesco Zambianchi
Francesco Zambianchi
RARoberto Adani
Roberto Adani
FCFabio Catani
Fabio Catani
Determining the rate of specific adverse events after volar plating performed for distal radius fractures. Retrospective. University level I trauma center. We searched the electronic database of all surgical procedures performed in our department using the following keywords: distal radius fracture, wrist fracture, and plate fixation. We identified 315 patients, 12 of whom were lost at follow-up. Volar plate fixation for the treatment of distal radius fractures. At an average follow-up of 5 years, 303 patients were evaluated through medical records and clinical and radiographic assessment for specific adverse events after volar plate fixation. Adverse events were observed in 18 patients (5.9%). Implant-related adverse events, including tendon impairments, intra-articular screws, and screw loosening, were observed in 15 patients (5.0%). Extensor tendon impairments were represented by 5 cases of extensor tenosynovitis and 3 cases of rupture of the extensor pollicis longus due to screws protruding dorsally. Flexor impairments were represented by 2 cases of tenosynovitis and 2 cases of flexor pollicis longus rupture. Screw penetration into the radioulnar joint was observed in 1 case. Loss of reduction was identified in 3 cases. One patient had a deep postoperative infection treated with operative debridement. One patient experienced injury to the median nerve during routine implant removal unrelated to tendon issues. The majority of adverse events after volar plate fixation were due to technical errors in implant placement. In our cohort, tendon impairments were the most frequently observed; among these, extensor tendon impairments were the most represented (50% of all adverse events). All 12 tendon-related adverse events were due to technical shortcomings with implant placement. Therapeutic level IV.

11 July 2013 in Journal of Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
Luigi TaralloLuigi Tarallo
Luigi Tarallo
RMRaffaele Mugnai
Raffaele Mugnai
FFFrancesco Fiacchi
Francesco Fiacchi
FCFrancesco Capra
Francesco Capra
FCFabio Catani
Fabio Catani
Background The treatment of radial neck fractures in children varies according to the displacement, angulation, and skeletal maturity. There is a general agreement that displaced radial neck fractures with more than 30° angulations (Judet type III and IV fractures) should be surgically treated. There are several treatment possibilities for Judet type III and IV fractures including percutaneous pin reduction, elastic stable intramedullary nailing (ESIN), and open reduction with or without internal fixation. In this retrospective study we compared the clinical and radiographical outcomes, and complications following intramedullary versus percutaneous pinning in displaced radial neck fractures in children. Materials and methods Between 2000 and 2011, 20 patients were treated using closed reduction: in 12 cases we used percutaneous pinning, and in 8 cases we used ESIN. According to Judet classification the two groups were composed as follows: 10 (77 %) type III and 3 (23 %) type IV fractures in the percutaneous pinning group; 4 (57 %) type III, and 3 (43 %) type IV fractures in the ESIN group. Results After an average of 42 months, excellent results in Mayo elbow performance scores (MEPS) were obtained in 71 and 69 % of ESIN and percutaneous pinning groups respectively, with good results in the remaining cases apart from one fair case (8 %) in the percutaneous pinning group. After a radiological evaluation, all fractures healed in excellent or good alignment. When comparing the two groups, the subjects treated with the ESIN technique had higher range of motion (ROM) in flexion, extension and pronation. No patients developed complications, except three cases of asymptomatic enlargements of the radial head, reported only in the percutaneous pinning group. Conclusion In this research the clinical outcome, assessed with the MEPS, and the radiological alignment, were comparable between the subjects that were treated with percutaneous pinning and those with ESIN techniques; whereas the ESIN technique demonstrated higher ROM in flexion, extension and pronation. The ESIN technique seems to be the ideal approach both for the higher ROM values and for the absence of complications.