Patrice Rivard

Prof. Patrice Rivard

Université de Sherbrooke, Sherbrooke, Quebec, Canada
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2011 in Construction and Building Materials
Verified
Journal Article
Closed access
MJMegat Azmi Megat Johari
Megat Azmi Megat Johari
JBJ.J. Brooks
J.J. Brooks
SKShahid Kabir
Shahid Kabir
Patrice RivardPatrice Rivard
Patrice Rivard

1 June 2010 in International Journal of Rock Mechanics and Mining Sciences
Verified
Journal Article
Closed access
ZMZ.A. Moradian
Z.A. Moradian
GBG. Ballivy
G. Ballivy
Patrice RivardPatrice Rivard
Patrice Rivard
CGC. Gravel
C. Gravel
BRB. Rousseau
B. Rousseau

1 August 2016 in Journal of Rock Mechanics and Geotechnical Engineering
Verified
Journal Article
Open access
NKNabassé J.F. Koupouli
Nabassé J.F. Koupouli
Tikou BelemTikou Belem
Tikou Belem
Patrice RivardPatrice Rivard
Patrice Rivard
HEHervé Effenguet
Hervé Effenguet
This paper presents the results of the shear strength (frictional strength) of cemented paste backfill-cemented paste backfill (CPB-CPB) and cemented paste backfill–rock wall (CPB-rock) interfaces. The frictional behaviors of these interfaces were assessed for the short-term curing times (3 d and 7 d) using a direct shear apparatus RDS-200 from GCTS (Geotechnical Consulting & Testing Systems). The shear (friction) tests were performed at three different constant normal stress levels on flat and smooth interfaces. These tests aimed at understanding the mobilized shear strength at the CPB-rock and CPB-CPB interfaces during and/or after open stope filling (no exposed face). The applied normal stress levels were varied in a range corresponding to the usually measured in-situ horizontal pressures (longitudinal or transverse) developed within paste-filled stopes (uniaxial compressive strength, σc ≤ 150 kPa). Results show that the mobilized shear strength is higher at the CPB-CPB interface than that at the CPB-rock interface. Also, the perfect elastoplastic behaviors observed for the CPB-rock interfaces were not observed for the CPB-CPB interfaces with low cement content which exhibits a strain-hardening behavior. These results are useful to estimate or validate numerical model for pressures determination in cemented backfill stope at short term. The tests were performed on real backfill and granite. The results may help understanding the mechanical behavior of the cemented paste backfill in general and, in particular, analyzing the shear strength at backfill–backfill and backfill-rock interfaces

1 October 2016 in Construction and Building Materials
Verified
Journal Article
Closed access
FSFrançois Saint-Pierre
François Saint-Pierre
APAlain Philibert
Alain Philibert
BGBernard Giroux
Bernard Giroux
Patrice RivardPatrice Rivard
Patrice Rivard

1 March 2016 in International Journal of Rock Mechanics and Mining Sciences
Verified
Journal Article
Closed access
AFAli Fathi
Ali Fathi
ZMZabihallah Moradian
Zabihallah Moradian
Patrice RivardPatrice Rivard
Patrice Rivard
GBGérard Ballivy
Gérard Ballivy

1 October 2012 in Cement and Concrete Research
Verified
Journal Article
Closed access
ARA. Rodrigues
A. Rodrigues
JDJ. Duchesne
J. Duchesne
BFB. Fournier
B. Fournier
BDB. Durand
B. Durand
Patrice RivardPatrice Rivard
Patrice Rivard
MSM. Shehata
M. Shehata