Bin Hu

Dr. Bin Hu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
XZXiyue Zou
Xiyue Zou
LWLi Wen
Li Wen
BHBin Hu
Bin Hu
Near-field passive wireless sensors can realize non-contact strain measurement, so these sensors have extensive applications in structural health monitoring. However, these sensors suffer from low stability and short wireless sensing distance. This paper presents a bulk acoustic wave (BAW) passive wireless strain sensor, which consists of two coils and a BAW sensor. The force-sensitive element is a quartz wafer with a high quality factor, which is embedded into the sensor housing, so the sensor can convert the strain of the measured surface into the shift of resonant frequency. A double-mass-spring-damper model is developed to analyze the interaction between the quartz and the sensor housing. A lumped parameter model is established to investigate the influence of the contact force on the sensor signal. Experiments show that a prototype BAW passive wireless sensor has a sensitivity of 4 Hz/με when the wireless sensing distance is 10 cm. The resonant frequency of the sensor is almost independent of the coupling coefficient, which indicates that the sensor can reduce the measurement error caused by misalignment or relative movement between coils. Thanks to the high stability and modest sensing distance, this sensor may be compatible with a UAV-based monitoring platform for the strain monitoring of large buildings.

22 February 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XZXiyue Zou
Xiyue Zou
BHBin Hu
Bin Hu
LWLi Wen
Li Wen
In this paper, we propose a passive wireless strain sensing system with magnetic resonance coupling and bulk acoustic wave strain sensor to evaluate the structural safety of mega structures. The bulk acoustic wave sensor provides a high-quality factor, and the magnetic resonance coupling enhances the transmitter’s gain at the system’s operational frequency. The experimental and analytical methods are investigated to characterize the effect of different parameters on this system. The results show that the sensing system can detect the resonant frequency of the receiver when the coupling coefficient is less than 0.01. Experimental demonstrations show that a prototype sensing system had a strain measurement range of 500 με and a resolution of 4 Hz/με when the separation distance between coils was 10 cm. Compared with conventional passive wireless sensing systems, the change of coupling coefficient has little effect on the resonant frequency of the receiver. We envision that this system has the potential to realize non-contact strain measurement while the measurement device is in an unsteady movement mode. In the future, this sensing system can be integrated into an unmanned aerial vehicle to measure the strain in mega structures.

1 January 2023 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
YWYinchu Wang
Yinchu Wang
HZHaijiang Zhu
Haijiang Zhu
YYYue Yu
Yue Yu
BHBin Hu
Bin Hu
With the development of robot technology, inspection robots have been applied to the defect detection of large tanks. However, the existing path planning algorithm of the tank bottom detection robot is easy to fall into the local minimum, and the path is not smooth. Besides, the positioning of the tank bottom detection robot is not accurate. This article proposes a path planning and location algorithm for the large tank bottom detection robot. Specifically, we design a preset spiral path according to the shape of the tank bottom, and a rotating potential field (RPF) near the obstacle is added to avoid the problem of path planning falling into a local minimum. We obtained accurate and smooth planning results. Compared with the state‐of‐the‐art, the RPF method reduced the average RMSE by 9.49%. In addition, by measuring the acoustic emission distance, the three‐point positioning algorithm can be used to achieve the calculation of the robot position detection in the proposed method, and the average positioning error on the spiral path is only 0.0748 ± 0.0032.

8 August 2022 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
LYLiang Yan
Liang Yan
BWBenLi Wan
BenLi Wan
BHBin Hu
Bin Hu
MFMengbao Fan
Mengbao Fan

13 June 2021 in Materials Technology
Verified
Journal Article
Closed access
YHYun Hu
Yun Hu
BHBin Hu
Bin Hu
YDYang Dingyu
Yang Dingyu
ZWZhaorong Wei
Zhaorong Wei
In this paper, we have achieved the hollow shell ZnS QDs with a simple preparation process, and deeply analysed the mechanism of hollow shell ZnS QDs (~10 nm). The co-doping of copper (Cu) and manganese (Mn) caused the cooperated effects on the ZnS quantum dots, in which hollow shell structure can be formed. The mechanism is that Mn2+ ions in ZnS matrix provide some diffusion channels allowing the outward movement of the Cu2+ ions. In addition, it has been shown that Cu doping at 0.2–0.3% and Mn doping at 3% could form hollow shell structure.

16 April 2026 in Electronics
Verified
Journal Article
Open access
PDF file
TTTianqi Tian
Tianqi Tian
YHYanzhu Hu
Yanzhu Hu
BHBin Hu
Bin Hu
YWyingjian Wang
yingjian Wang
XZXinghao Zhao
Xinghao Zhao
With the rapid development of underground spaces and demand for infrastructure-independent autonomous positioning in post-disaster rescue, Pedestrian Dead Reckoning (PDR) has become a key research focus. However, traditional PDR suffers from cumulative heading drift, inadequate 3D positioning performance, and poor anti-magnetic interference capabilities, failing to meet the high-precision positioning requirements of rescuers in underground and multistory buildings. To address these issues, this paper proposes an adaptive 3D-PDR method fusing inertial, geomagnetic, and barometric (3D-IMB-APDR). Sensor data are optimized via FFT dominant frequency extraction and Butterworth zero-phase filtering, with magnetic interference compensated by geomagnetic ellipse fitting. A segmental heading correction with a multi-criteria dynamic geomagnetic reliability model suppresses heading drift. A barometer-based coarse estimation and inertial fine correction architecture is adopted, where a lightweight CNN-BiLSTM network extracts inertial features for step height, and AEKF fuses multi-source data to achieve accurate vertical height estimation and precise 3D positioning. Validated in sports fields, underground parking garages, and staircases, the method outperforms four comparative methods, reducing positional RMSE by 65.77–98.23%, with endpoint errors of 1.40 m, 2.56 m, and 0.32 m, respectively. Relying solely on chest-worn sensors, it provides a reliable 3D autonomous positioning solution for rescuers in post-disaster rescue and underground engineering.