Chan Jun Qiang

Mr. Chan Jun Qiang

Department of Electrical Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
CQChan Jun Qiang
Chan Jun Qiang
WRWong Jee Keen Raymond
Wong Jee Keen Raymond
HIHazlee Azil Illias
Hazlee Azil Illias
MOMohamadariff Othman
Mohamadariff Othman
Monitoring the partial discharge (PD) activity of power equipment insulation is crucial to ensure uninterrupted power system operation. PD occurrence is highly correlated to weakened insulation strength. If PD occurrences are left unchecked, unexpected insulation breakdowns may occur. The comprehensive PD diagnostic process includes the detection, localization, and classification of PD. Accurate PD source localization is necessary to locate the weakened insulation segment. As a result, rapid and precise PD localization has become the primary focus of PD diagnosis for power equipment insulation. This paper presents a review of different approaches to PD localization, including conventional, machine learning (ML), and deep learning (DL) as a subset of ML approaches. The review focuses on the ML and DL approaches developed in the past five years, which have shown promising results over conventional approaches. Additionally, PD detection using conventional, unconventional, and a PCB antenna designed based on UHF techniques is presented and discussed. Important benchmarks, such as the sensors used, algorithms employed, algorithms compared, and performances, are summarized in detail. Finally, the suitability of different localization techniques for different power equipment applications is discussed based on their strengths and limitations.

10 September 2024 in IEEE Access
Verified
Journal Article
Open access
SAS. M. KAYSER AZAM
S. M. KAYSER AZAM
CQChan Jun Qiang
Chan Jun Qiang
MOMohamadariff Othman
Mohamadariff Othman
WRWong Jee Keen Raymond
Wong Jee Keen Raymond
HIHazlee Azil Illias
Hazlee Azil Illias
ARAbd Karim Abd Rahman
Abd Karim Abd Rahman
Insulations at high voltage (HV), whether in HVAC or HVDC systems, often encounter an unwanted partial discharge (PD) phenomenon. PD poses a potential danger to HV insulation and can eventually lead to equipment failures. Out of all electromagnetic (EM) sensing techniques for PD diagnosis, the ultra-high frequency (UHF) method has gained popularity as it allows non-invasive detection at varying distances from PD defects. The EM behavior of PD is significantly affected by the distance between a PD defect and a UHF sensor. This effect varies for different PD defects under different HV conditions. So, considering variable distances, there is a need to analyze EM characteristics of different PD phenomena at different HV conditions. To the best of our knowledge, for the first time, electromagnetic characteristics of different PD defects are experimentally investigated in this work by capturing PD signals from variable distances in both HVAC and HVDC conditions and individually validating their characteristics with EM radiation theories. For wirelessly capturing PD signals, a new UHF sensor is designed with a modified elliptical-shaped antenna on an FR-4 material. The fabricated sensor provides an average realized gain of about 3.66 dBi while covering more than 97% of the total UHF range for PD detection. Applying HVAC, HVDC+, and HVDC–, PDs from three defects (surface, void, free wire) are captured from 1–4 m distances. Interpreted results show that EM radiation in the UHF range from a PD defect is heavily impacted by its detection distance and defect formation despite applied voltage and other conditions being unchanged for the defect. This investigation is particularly beneficial to the variable distance-based PD diagnosis, such as PD localization and handheld PD detection at HVAC/HVDC open substations.

5 September 2025 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
CQChan Jun Qiang
Chan Jun Qiang
SAS. M. KAYSER AZAM
S. M. KAYSER AZAM
WRWong Jee Keen Raymond
Wong Jee Keen Raymond
HIHazlee Azil Illias
Hazlee Azil Illias
MOMohamadariff Othman
Mohamadariff Othman

22 September 2025 in Measurement
Verified
Journal Article
Closed access
CQChan Jun Qiang
Chan Jun Qiang
SAS.M. Kayser Azam
S.M. Kayser Azam
WRWong Jee Keen Raymond
Wong Jee Keen Raymond
HIHazlee Azil Illias
Hazlee Azil Illias
MOMohamadariff Othman
Mohamadariff Othman

2 June 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
HCHakima Cherif
Hakima Cherif
CPCiptian Weried Priananda
Ciptian Weried Priananda
HIHazlee Azil Illias
Hazlee Azil Illias
CQChan Jun Qiang
Chan Jun Qiang
WRWong Jee Keen Raymond
Wong Jee Keen Raymond
ACAli Chemsa
Ali Chemsa
Partial discharge (PD) monitoring is essential for the condition assessment of air-insulated switchgear (AIS). This paper presents an experimental framework that acquires ultra-high-frequency (UHF) PD signals corresponding to four representative insulation defects: corona, surface, floating electrode, and triple junction. The collected signals are transformed into time–frequency representations using the Continuous Wavelet Transform (CWT) and the Wavelet Synchrosqueezing Transform (WSST) with two analytic mother wavelets, namely Amor and Bump. The resulting scalograms are employed as inputs to a convolutional neural network (CNN) for training and are evaluated using 5-fold cross-validation for PD classification. Comparative results show that WSST consistently improves class separability over CWT across both wavelets, where the WSST-Amor configuration achieves the best overall accuracy of 98.02%, surpassing CWT-Amor, WSST-Bump, and CWT-Bump. Compared to traditional phase-resolved partial discharge (PRPD) approaches, which require larger datasets and more complex acquisition setups, the proposed scalogram-based method provides rich feature representations using fewer signals, offering a more practical and efficient pathway for automated PD diagnosis in AIS.

29 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
CPCiptian Weried Weried Priananda
Ciptian Weried Weried Priananda
HIHazlee Azil Illias
Hazlee Azil Illias
WRWong Jee Keen Raymond
Wong Jee Keen Raymond
CQChan Jun Qiang
Chan Jun Qiang
HCHakima Cherif
Hakima Cherif
INI Made Yulistya Negara
I Made Yulistya Negara
Partial discharge (PD) analysis is essential for assessing the insulation condition of high-voltage rotating machines, as undetected defects may lead to severe failures and operational downtime. However, existing PD diagnostic approaches often rely on phase-resolved measurements or lack robustness under noisy conditions, limiting their applicability in practical environments. This study proposes a robust diagnostic framework integrating waveform-based PD acquisition, wavelet-based scalogram representation, and a hybrid CNN-SE-Transformer deep learning architecture. The proposed approach transforms non-stationary PD signals into time-frequency scalograms using both the Discrete Wavelet Transform (DWT) and Continuous Wavelet Transform (CWT), enabling enhanced feature representation. The hybrid model combines CNN-based local feature extraction, squeeze-and-excitation attention, and transformer-based global feature modeling. The framework is evaluated using a balanced dataset of six PD defect types under both clean and noisy conditions with a modified five-fold cross-validation strategy. Under clean conditions, the proposed model achieves a maximum classification accuracy of 97.25\% using CWT scalograms, outperforming conventional CNN and CNN-SE models. Robustness evaluation under various artificial noise scenarios further demonstrates that the proposed method maintains stable performance, with CWT-based representations providing superior resilience compared to raw signals and DWT scalograms. Compared to conventional PRPD approaches requiring phase synchronization and specialized instrumentation, the proposed framework offers a simpler yet effective alternative for practical PD-based condition monitoring in high-voltage rotating machines.