Digital hydraulics uses simple and cheap on/off valves in order to replace expensive proportional valves. Furthermore, with fast switching hydraulic converters the energy efficiency can be raised compared to proportional valve control. The hydraulic buck converter (HBC) represents an energy efficient and cost-effective switched inertance system, because its inductance is realized by a simple pipe. In this paper, a prototype for a hydraulic linear cylinder drive controlled by an HBC is presented. Characteristic for this drive axis is that the HBC is directly mounted on the cylinder, which allows a reduction of the oil transport loss between the axis and the hydraulic power supply unit. Furthermore, piston accumulators are used for decoupling and pressure attenuation. Due to their robustness regarding the prepressure to operating pressure, the load pressure can be controlled arbitrary in the piston-sided chamber. The energy performance and the tracking behavior of the axis with a flatness-based control (FBC) are investigated by steady-state measurements and dynamic trajectories, respectively. The results are discussed and an outlook about further improvements of the concept is provided.
Primary control of linear motion by variable speed electric motors driving a hydraulic cylinder via a constant displacement pump is an established and successful concept with a frequent use in industry. One problem arises when low or zero motion speed has to be realized under high pump pressure conditions. Such load scenarios occur frequently in certain pressing processes, e.g., for sintering or veneering. Most pumps have a lower speed limit, below which critical tribological conditions occur which impair lifespan and efficiency. In addition, pump speed control and pump fluctuation suffer from the mixed lubrication conditions in such an operation range. For a circumvention of such low speed pump operation, a digital valve control concept is presented and studied in this paper. Valve control is used in load holding phases with low speed. Pressure is provided by an accumulator which is charged by the pump in short charging cycles at reasonable pump speeds. It is shown that the mean control error during load holding phase lies within the desired band and the fluctuations of the control force are lower than those of the pump control. In addition, the unfavorable pump operation conditions can be avoided via digital control.
9 July 2021 in Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering
The control of hydraulic cylinders with digital hydraulic valves is often based on modulation principles like pulse-width modulation, pulse-code modulation, or pulse–frequency control. In many cases the dynamic drive performance using such control strategies is far below the natural dynamics of the system, since closed-loop controllers demand a certain phase margin for stability. However, some drive applications require a high dynamic response, which cannot be realized with common closed-loop concepts. In this article the design of a bang–bang feedforward control with regard to the dynamics of a hydraulic cylinder drive in accordance with the theory of optimal control is presented. The control achieves the maximum physical dynamic response and no remaining oscillations after the movement, which forms the basis of a high dynamic three-level position control for hydraulic drives. Furthermore, the influence of valve dynamics and pipe line dynamics with regard to the design of the digital valve control are considered by simulations.
This paper presents the application of a hydraulic DC-DC converter, namely a step down Buck Converter to the actuation of a robot leg that is part of the quadruped robot HyQ. The use of a Hydraulic Buck Converter (HBC) offers significant advantages in terms of improved efficiency of hydraulic actuation systems analogously to an electric switching DC-DC converter as opposed to a rheostatic-type system. In this paper, a HBC consisting of two digital valves and two check valves is introduced to improve the efficiency performance of a singl leg of a hydraulic quadruped robot (HyQ). This type of hydraulic buck converter is able to support the locomotion in two directions. The HBC operates at a switching frequency of 100 Hz in pulse-width-modulation. The better energy performance compared to proportional control is achieved by the use of fast check valves. The performance of the system with a 3-way-4-position proportional valve is compared with the HBC drive. A test rig is set up to investigate the performance of HBC with two different controllers and a Hydraulic Proportional Drive (HPD) system, based on proportional valves which control flow, by throttling it, in a dissipative manner. The performance of position tracking and energy consumption is evaluated. The experimental results indicate that HBC systems can achieve similar position tracking with relatively less consumed energy.
25 May 2015 in Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering
Hydraulic switching control is an opportunity for economic, robust and energy efficient hydraulic motion control. The hydraulic buck converter represents a promising concept, which meets these requirements. Part I of this publication has shown that for a convenient control performance a model-based control should be applied. In this paper a flatness-based controller for linear hydraulic motion control with a sub-kilowatt hydraulic buck converter is presented. A simple model-based on an averaging of the switching converter is employed to derive a flatness-based controller combined with a nonlinear observer to estimate all system states only from a position signal. Its performance is studied by simulations and experiments for large ramp type and sinusoidal motions of a heavy mass. Comparison of motion quality and energy consumption are made between the converter and a standard hydraulic proportional drive using a servo-valve instead of the switching converter. With this flatness-based controller a tracking performance as good as of a proportional drive can be achieved, yet at much better efficiency. Proportional control for the switching converter, however, leads to inferior results for this type of intended motions.