Photovoltaic (PV) systems can reduce greenhouse gas emissions while providing rapid reactive power support to the electric grid. At the distribution grid level, the PV inverters are controlled to reduce the system’s active power loss and to address problems caused by the PV systems themselves. For example, the distribution grid may face overvoltages due to high PV generation during off-peak hours. In this paper, a reactive power control approach for PV inverters is proposed to control the injection/absorption of reactive power to reduce the active power loss of the system while solving the overvoltage problem. To achieve this, the proposed controller periodically dispatches the reactive power setpoints and applies a real-time volt/var algorithm. The proposed method uses probabilistic distributions to account for the uncertainties in PV generation and load demand. The controller is implemented at the lateral level which simplifies the required communication platform and reduces the computational cost. The real-time volt/var control coordinates the operation of the different inverters during overvoltage conditions so that the voltage rise is limited using as little reactive power as possible by the inverters. Accordingly, the active power loss due to reactive power flow in the system is reduced. Two distribution systems are simulated using Open Distribution System Simulator (OpenDSS) and used to evaluate the proposed controller and compare with two other methods. A daily time series simulation is performed to test different operating conditions. The simulation results show that the proposed controller is able to reduce the active power loss in general and solve the overvoltage problem with a lower reactive power requirement than the other volt/var methods.
16 October 2019 in IEEE Transactions on Smart Grid
This paper presents a single end fault location scheme for distribution networks with distributed generation (DG). The high frequency transients generated when a fault occurs are used to locate the fault point. An equivalent circuit at high frequencies is derived for both inverter based and synchronous DGs. The voltages and currents measured only at the main substation are used in conjunction with the proposed DG model to create the fault location scheme. The distributed parameter line model is employed in the derivation to account for the line characteristics e.g. inductive and capacitive mutual coupling and untransposed lines. The inverter based DG model is validated experimentally on a 400 V, three-phase system. The IEEE 34-bus feeder is simulated and used to evaluate the proposed scheme for different operating conditions e.g. fault resistance and DG conditions. The extensive simulation studies show the accuracy of the proposed scheme with 95.3% of the test cases having an absolute error in estimation of less than 200 m.
Accurate and fast fault monitoring system is important for photovoltaic (PV) systems to reduce the damage and energy loss associated with faults. This paper presents a fast fault detection and classification scheme for PV systems. The rate of change of the measured power at the array level is firstly used to detect and differentiate between shading and PV system short-circuit faults. Then, the measured cross-strings differential currents classify the fault type in the case of short-circuit faults. The proposed method accounts for intra-string, string-to-negative terminal, cross-string (string to string), and pole-to-pole short-circuit faults, as well as open circuit faults. Two current transducers per two strings are only required to apply the method leading to a significant reduction in the number of transducers/sensors compared to the literature, making it a cost-effective solution. The fault is detected and classified in 1 ms. A 400 kW PV system consisting of 4 arrays simulated using MATLAB/Simulink package is used for the evaluation process. Short-circuit faults are imposed at different conditions of mismatch levels and fault resistance values. Also, operation at reduced irradiance level is considered, and shading faults are simulated in different levels. The simulation results prove the ability of the proposed scheme to detect and differentiate between shading and short-circuit faults. The proposed method can correctly classify different fault types in almost all cases. The low implementation cost due to the lower number of required sensors and the fast-operating time (1 ms) boost the feasibility of the proposed method.
Electric distribution grids are seeing an increased penetration of photovoltaic (PV) generation. High PV generation exceeding the grid load demand results in a reverse active power flow in the grid, which raises the voltage level. This paper presents a reactive power controller to overcome the overvoltage problem in the distribution system. A sequentially coordinated and cooperative volt/var control technique is presented. The proposed controller aims to use as low reactive power as possible while mitigating the voltage issues. Accordingly, it reduces the active power loss associated with reactive power flow and reduces the probability for active power curtailment of the PV system. The controller is developed for each lateral and is replicated for all laterals. The lateral controller coordinates the operation of the smart PV inverters in a sequential manner. Cooperative control is proposed between the laterals’ controllers as well and is engaged when the individual laterals’ controllers are unable to solve their overvoltage issues. The performance of the proposed controller is evaluated by comparing it to two other volt/var controllers, and it demonstrates better performance in terms of reactive power requirement. To conduct the simulation study, a modified version of the unbalanced IEEE 13-bus system is utilized, which includes an additional 44 low-voltage bus. The study involves simulating 720 operating points across daily time series. The results indicate that the proposed controller effectively addresses overvoltage problems that occur during periods of high PV generation.
This paper presents a fault location technique for distribution systems. It is a two end impedance based technique that uses the fault generated transients to estimate the fault distance over a broad range of frequencies. Then, curve fitting is applied to find the final estimated fault distance. Firstly, the paper introduces the method for the system represented as a lumped RL model. Then, generalized to consider the distribution line capacitance. The technique accounts for presence of loading taps, heterogeneous feeder sections, single phase, two phase and three phase loads and unbalance in distribution system. Single line to ground, line to line, and three phase faults are considered at different fault resistance values up to 100 Ω. Also, the effect of fault inception angle and resolution of analogue to digital converter is investigated. IEEE 34 nodes system is used to evaluate the proposed method.