Alejandro Portela Otano

Dr. Alejandro Portela Otano

Bioengineering, Universitat Internacional de Catalunya, Barcelona, Catalonia, Spain
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Xavier MarimonXavier Marimon
Xavier Marimon
IMItziar Mengual
Itziar Mengual
Carlos López-de-CelisCarlos López-de-Celis
Carlos López-de-Celis
AOAlejandro Portela Otano
Alejandro Portela Otano
Jacobo Rodríguez-SanzJacobo Rodríguez-Sanz
Jacobo Rodríguez-Sanz
Albert Pérez-BellmuntAlbert Pérez-Bellmunt
Albert Pérez-Bellmunt
Background: Gait is the manner or style of walking, involving motor control and coordination to adapt to the surrounding environment. Knowing the kinesthetic markers of normal gait is essential for the diagnosis of certain pathologies or the generation of intelligent ortho-prostheses for the treatment or prevention of gait disorders. The aim of the present study was to identify the key features of normal human gait using inertial unit (IMU) recordings in a walking test. Methods: Gait analysis was conducted on 32 healthy participants (age range 19–29 years) at speeds of 2 km/h and 4 km/h using a treadmill. Dynamic data were obtained using a microcontroller (Arduino Nano 33 BLE Sense Rev2) with IMU sensors (BMI270). The collected data were processed and analyzed using a custom script (MATLAB 2022b), including the labeling of the four relevant gait phases and events (Stance, Toe-Off, Swing, and Heel Strike), computation of statistical features (64 features), and application of machine learning techniques for classification (8 classifiers). Results: Spider plot analysis revealed significant differences in the four events created by the most relevant statistical features. Among the different classifiers tested, the Support Vector Machine (SVM) model using a Cubic kernel achieved an accuracy rate of 92.4% when differentiating between gait events using the computed statistical features. Conclusions: This study identifies the optimal features of acceleration and gyroscope data during normal gait. The findings suggest potential applications for injury prevention and performance optimization in individuals engaged in activities involving normal gait. The creation of spider plots is proposed to obtain a personalised fingerprint of each patient’s gait fingerprint that could be used as a diagnostic tool. A deviation from a normal gait pattern can be used to identify human gait disorders. Moving forward, this information has potential for use in clinical applications in the diagnosis of gait-related disorders and developing novel orthoses and prosthetics to prevent falls and ankle sprains.

19 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Andoni Carrasco-UribarrenAndoni Carrasco-Uribarren
Andoni Carrasco-Uribarren
Xavier MarimonXavier Marimon
Xavier Marimon
FDFlora Dantony
Flora Dantony
Sara Cabanillas-BareaSara Cabanillas-Barea
Sara Cabanillas-Barea
AOAlejandro Portela Otano
Alejandro Portela Otano
Albert Masip-AlvarezAlbert Masip-Alvarez
Albert Masip-Alvarez
As its name implies, the forward head position (FHP) is when the head is further forward of the trunk than normal. This can cause neck and shoulder tension, as well as headaches. The craniovertebral angle (CVA) measured with 2D systems such as Kinovea software is often used to assess the FHP. Computer vision applications have proven to be reliable in different areas of daily life. The aim of this study is to analyze the test-retest and inter-rater reliability and the concurrent validity of a smartphone application based on computer vision for the measurement of the CVA. Methods: The CVAs of fourteen healthy volunteers, fourteen neck pain patients, and fourteen tension-type headache patients were assessed. The assessment was carried out twice, with a week of rest between sessions. Each examiner took a lateral photo in a standing position with the smartphone app based on computer vision. The test-retest reliability was calculated with the assessment of the CVA measured by the smartphone application, and the inter-rater reliability was also calculated. A third examiner assessed the CVA using 2D Kinovea software to calculate its concurrent validity. Results: The CVA in healthy volunteers was 54.65 (7.00); in patients with neck pain, 57.67 (5.72); and in patients with tension-type headaches, 54.63 (6.48). The test-retest reliability was excellent, showing an Intraclass Correlation Coefficient (ICC) of 0.92 (0.86–0.95) for the whole sample. The inter-rater reliability was excellent, with an ICC of 0.91 (0.84–0.95) for the whole sample. The standard error of the measurement with the app was stated as 1.83°, and the minimum detectable change was stated as 5.07°. The concurrent validity was high: r = 0.94, p < 0.001. Conclusion: The computer-based smartphone app showed excellent test-retest and inter-rater reliability and strong concurrent validity compared to Kinovea software for the measurement of CVA.

2 May 2016 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
AOAlejandro Portela Otano
Alejandro Portela Otano
TYTaka‐Aki Yano
Taka‐Aki Yano
CSChristian Santschi
Christian Santschi
OMOlivier J.F. Martin
Olivier J.F. Martin
HTHitoshi Tabata
Hitoshi Tabata
MHMasahiko Hara
Masahiko Hara
The cyclic RGD (cRGD) peptide ligands of cells have become widely used for treating several cancers. We report a highly sensitive analysis of c(RGDfC) using surface enhanced Raman spectroscopy (SERS) using single dimer nanogap antennas in aqueous environment. Good agreement between characteristic peaks of the SERS and the Raman spectra of bulk c(RGDfC) with its peptide's constituents were observed. The exhibited blinking of the SERS spectra and synchronization of intensity fluctuations, suggest that the SERS spectra acquired from single dimer nanogap antennas was dominated by the spectrum of single to a few molecules. SERS spectra of c(RGDfC) could be used to detect at the nanoscale, the cells' transmembrane proteins binding to its ligand. SERS of cyclic RGD on nanogap antenna.

Verified
Journal Article
Open access
PDF file
Andoni Carrasco-UribarrenAndoni Carrasco-Uribarren
Andoni Carrasco-Uribarren
Xavier MarimonXavier Marimon
Xavier Marimon
AOAlejandro Portela Otano
Alejandro Portela Otano
Sara Cabanillas-BareaSara Cabanillas-Barea
Sara Cabanillas-Barea
PRPere Ramón Rodríguez-Rubio
Pere Ramón Rodríguez-Rubio
Roman PerezRoman Perez
Roman Perez
Introduction: Neck pain is one of the most frequent reasons for consultation in primary care. Clinicians evaluate different variables, including movement and cervical strength, to determine the prognosis of patients. Usually, the tools employed for this purpose are expensive and bulky, or more than one is needed. This study aims to describe a novel device designed to assess the cervical spine and describe its test–retest reliability. Methods: The Spinetrack device was designed to measure the strength of deep cervical flexor muscles and the chin-in and chin-out movement of the upper cervical spine. A test–retest reliability study was developed. The flexion, extension and strength needed to move the Spinetrack device were registered. Two measurements were developed, with one week between each assessment. Results: Twenty healthy subjects were evaluated. The strength of the deep cervical flexor muscles in the first measurement was 21.18 ± 3.15 Newtons, the displacement movement during chin-in movement was 12.79 mm ± 3.46 and the displacement during chin-out movement was 35.99 mm ± 4.44. The test–retest reliability of strength was ICC 0.97 (95% CI (0.91–0.99)). Conclusion: The Spinetrack device has shown excellent test–retest reliability values for the measurement of the strength of the cervical flexor muscles and for the chin-in and chin-out movements.

23 June 2026 in Pediatric Reports
Verified
Journal Article
Open access
PDF file
GDGeorgina Domènech-Garcia
Georgina Domènech-Garcia
Xavier MarimonXavier Marimon
Xavier Marimon
Andoni Carrasco-UribarrenAndoni Carrasco-Uribarren
Andoni Carrasco-Uribarren
AOAlejandro Portela Otano
Alejandro Portela Otano
Caritat Bagur-CalafatCaritat Bagur-Calafat
Caritat Bagur-Calafat
Background: Artificial intelligence (AI)-driven markerless motion capture (MMC) technologies are increasingly being integrated into pediatric healthcare to improve the assessment and management of movement disorders. These video-based systems enable non-invasive motion analysis without wearable sensors, facilitating more natural movement assessment in children, particularly those with neurological or developmental conditions. Objectives: We evaluated the clinical applicability of AI-based MMC tools in pediatric settings for diagnosis, monitoring of motor development, and rehabilitation. Methods: This systematic review was registered in PROSPERO (CRD42024511787) and conducted by two independent reviewers, with a third reviewer resolving disagreements. The literature published between 2018 and 2025 was systematically searched. Studies involving pediatric populations or clinically relevant pediatric applications of MMC were included. Results: Of 1521 identified studies, 52 were finally selected. The included studies evaluated populations across a wide age range. However, seven of the included articles were specifically focused on underage populations. Infant studies primarily analyzed whole-body movements, emphasizing the relevance of global motor patterns in early development. OpenPose and AlphaPose were the most frequently used frameworks in pediatric research because of their automatic full-body key point detection, whereas DeepLabCut was commonly selected for its customizable labeling capabilities. Theia3D emerged as a promising clinically applicable solution with high accuracy. Most studies evaluated kinematic parameters as objective markers of motor performance and development. However, methodological heterogeneity and limited pediatric-specific validation remain important limitations. Conclusions: AI-driven MMC technologies show considerable potential to support objective, accessible, and child-friendly movement assessment in pediatric clinical practice.