Diego F. Villegas

Dr. Diego F. Villegas

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Journal of Biomechanics
Verified
Journal Article
Closed access
DVDiego F. Villegas
Diego F. Villegas
JMJason A. Maes
Jason A. Maes
SMSarah D. Magee
Sarah D. Magee
TDTammy L. Haut Donahue
Tammy L. Haut Donahue

1 February 2010 in Journal of Biomechanics
Verified
Journal Article
Closed access
KHKaren N. Hauch
Karen N. Hauch
DVDiego F. Villegas
Diego F. Villegas
TDTammy L. Haut Donahue
Tammy L. Haut Donahue

13 November 2007 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
DVDiego F. Villegas
Diego F. Villegas
THTara A. Hansen
Tara A. Hansen
DLDong F. Liu
Dong F. Liu
TDTammy L. Haut Donahue
Tammy L. Haut Donahue

1 February 2011 in Journal of Biomechanics
Verified
Journal Article
Closed access
AAAdam C. Abraham
Adam C. Abraham
JMJohn T. Moyer
John T. Moyer
DVDiego F. Villegas
Diego F. Villegas
Gregory OdegardGregory Odegard
Gregory Odegard
TDTammy L. Haut Donahue
Tammy L. Haut Donahue

13 April 2010 in Connective Tissue Research
Verified
Journal Article
Closed access
PDF file
DVDiego F. Villegas
Diego F. Villegas
TDTammy L. Haut Donahue
Tammy L. Haut Donahue
Qualitative analysis of meniscal attachments from five human knees was completed using scanning electron microscopy (SEM). In addition, quantitative analysis to determine the collagen crimping angle and length in each attachment was done. Morphological differences were revealed between the distinct zones of the attachments from the meniscus transition to the bony insertion. Collagen fibers near to the meniscus appeared inhomogeneous in a radial cross-section view. The sheath surrounding the fibers seemed loose compared with the membrane wrapping around the fibers in the menisci. The midsubstance of human meniscal attachments was composed of collagen fibers running parallel to the longitudinal axis, with a few fibers running obliquely, and others transversely. The bony insertion showed that the crimping pattern vanishes as the collagen fibers approach the fibrocartilagenous enthesis. There were no differences between attachments for crimping angle or length. Collagen crimping angles for all attachments were similar with values of approximately 22°. Crimp length values tended to be smaller for the medial attachments (MA: 4.76 ± 1.95 μm; MP: 3.72 ± 2.31 μm) and higher for the lateral (LA: 6.49 ± 2.34 μm, LP: 6.91 ± 2.29 μm). SEM was demonstrated to be an effective method for revealing the morphology of fibrous connective tissue. The data of collagen fiber length and angle found in this study will allow for better development of microstructural models of meniscal attachments. This study will help to better understand the relation between the morphology and the architecture of collagen and the mechanical behavior of meniscal attachments.

17 June 2013 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
AAAdam C. Abraham
Adam C. Abraham
DVDiego F. Villegas
Diego F. Villegas
KKKenton Kaufman
Kenton Kaufman
TDTammy L. Haut Donahue
Tammy L. Haut Donahue
This study investigated the internal fluid pressure of human cadaver meniscal root attachments. A pressure micro‐sensor was implanted inside each attachment site. Tibiofemoral joints were compressed to 2× body weight at various flexion angles and pressure recorded for 20 min. The anterior cruciate ligament (ACL) was then transected and joints retested. Lastly, a longitudinal incision of the lateral posterior (LP) horn was made and the joint retested. Ramp pressure was defined as the pressure when 2× body weight was reached, and equilibrium pressure was recorded at the end of the hold period. The medial posterior (MP) attachment was subjected to greater ramp pressure than the medial anterior (p = 0.002) and greater equilibrium pressure than all other root attachment sites (p < 0.001). Flexion angle had a significant effect on pressure as full extension was greatest at ramp (p = 0.040). Transection of the ACL decreased ramp pressure in the LP attachment (p = 0.025) and increased equilibrium pressure (p = 0.031) in the MP attachment. The results suggest that repair strategies should be developed which reconstruct the MP attachments to be sufficient to withstand large pressures. Furthermore, since meniscal pressure is highest at full extension, this fact should be considered when prescribing rehabilitation following repair of an attachment. © 2013 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 31:1507–1513, 2013