Asma'a Al-Ekrish

Prof. Asma'a Al-Ekrish

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2012 in The Saudi Dental Journal
Verified
Journal Article
Open access
AAAsma'a Al-Ekrish
Asma'a Al-Ekrish
Objectives: To investigate the accuracy and reliability of implant site measurements, recorded from low-dose cone beam computed tomography (CBCT) images. Methods: CBCT reformatted images of five skulls were obtained using 40, 20 and 7 s exposure protocols. From these protocols, edentulous ridge dimensions were recorded by two observers and compared with measurements recorded directly from the bone. The measurement errors and intra- and inter-examiner reliability were calculated for each exposure protocol and compared with each other. Results: The mean absolute errors from the 40, 20 and 7 s protocols were 0.50, 0.46, and 0.51 mm, respectively. The intra-examiner reliability scores were 0.996, 0.995 and 0.998, respectively. The inter-examiner reliability scores were 0.993, 0.998 and 0.994, respectively. There was no significant difference in accuracy or reliability between the three protocols. Conclusions: In imaging of dry skulls, lowering the CBCT exposure time from 40 s to 20 or 7 s does not affect the reliability or accuracy of implant site measurements.

10 January 2022 in The Saudi Dental Journal
Verified
Journal Article
Open access
MAMona Alsomali
Mona Alsomali
SAShatha Alghamdi
Shatha Alghamdi
SAShahad Alotaibi
Shahad Alotaibi
SASara A Alfadda
Sara A Alfadda
NANajwa Altwaijry
Najwa Altwaijry
AAAsma'a Al-Ekrish
Asma'a Al-Ekrish
To develop a Deep Learning Artificial Intelligence (AI) model that automatically localizes the position of radiographic stent gutta percha (GP) markers in cone beam computed tomography (CBCT) images to identify proposed implant sites within the images, and to test the performance of the newly developed AI model. Thirty-four CBCT datasets were used for initial model training, validation and testing. The CBCT datasets were those of patients who had a CBCT examination performed wearing a radiographic stent for implant treatment planning. The datasets were exported in Digital Imaging and Communications in Medicine (DICOM), then imported into the software Horos ®. Each GP marker was manually labelled for object detection and recognition by the deep learning model by drawing rectangles around the GP markers in all axial images, then the labelled images were split into training, validation, and test sets. The axial sections of 30 CBCT datasets were randomly divided into training and validation sets. four CBCT datasets were used for testing the performance of the deep learning model. Descriptive statistics were calculated for the number of GP markers present, number of correct and incorrect identifications of GP markers. The AI model had an 83% true positive rate for identification of the GP markers. Of the areas labelled by the AI model as GP markers, 28 % were not truly GP markers, but the overall false positive rate was 2.8 %. An AI model for localization of GP markers in CBCT images was able to identify most of the GP markers, but 2.8% of the results were false positive and 17% were missed GP markers. Using only axial images for training an AI program is not enough to give an accurate AI model performance.

6 August 2020 in The Saudi Dental Journal
Verified
Journal Article
Open access
AAAsma'a Al-Ekrish
Asma'a Al-Ekrish
To measure and compare the accuracy of the linear dimensions of implant sites recorded from cone beam computed tomography (CBCT) images using Blue Sky Plan, coDiagnostiX, and RadiAnt. Five human dry skulls were imaged with a CBCT device then sectioned to obtain sample transverse cross-sections of the edentulous ridges, and the height and width of the ridge were measured with a digital caliper to provide the gold standard measurements. The CBCT datasets were exported in DICOM format and imported into the three test software programs which were used to obtain reformatted sectional images corresponding to the sample transverse cross-sections, and the height and width of the edentulous ridge was recorded using the linear measurement tool. Reliability of the measurements were measured using the intraclass correlation coefficient. One-sample t-test (test value: zero) was used to test the statistical significance of the mean of the absolute errors for each software program. Analysis of Variance with Repeated Measures was used to test the statistical significance of the difference between the means of the absolute errors obtained by the different software programs. Statistical significance was set at a p-value of 0.05. The reliability of the gold standard and image measurements were excellent. All three software programs demonstrated a statistically significant mean absolute measurement error of between 0.43 and 0.56 mm (p-value < 0.01), but no significant difference in error values was found between any of the tested programs (p- value = 0.18). There was no statistically significant difference in accuracy of linear CBCT measurements of implant sites recorded using Blue Sky Plan, coDiagnostiX, and RadiAnt.

2 July 2020 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
DAD. M. AlMadi
D. M. AlMadi
MAM. A. Al‐Hadlaq
M. A. Al‐Hadlaq
OAO. AlOtaibi
O. AlOtaibi
RAR. S. Alshagroud
R. S. Alshagroud
AAAsma'a Al-Ekrish
Asma'a Al-Ekrish

16 June 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
AAAsma'a Al-Ekrish
Asma'a Al-Ekrish
SASara A Alfadda
Sara A Alfadda
WAWadea Ameen
Wadea Ameen
RHRomed Hoermann
Romed Hoermann
WPWolfgang Puelacher
Wolfgang Puelacher
GWGerlig Widmann
Gerlig Widmann
To compare the surface of computer-aided design (CAD) models of the maxilla produced using ultra-low MDCT doses combined with filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) reconstruction techniques with that produced from a standard dose/FBP protocol.

13 October 2018 in Oral Radiology
Verified
Journal Article
Open access
PDF file
AAAsma'a Al-Ekrish
Asma'a Al-Ekrish
RAReema Al-Shawaf
Reema Al-Shawaf
WAWafa Alfaleh
Wafa Alfaleh
RHRomed Hörmann
Romed Hörmann
WPWolfgang Puelacher
Wolfgang Puelacher
GWGerlig Widmann
Gerlig Widmann
Objective To assess the linear measurements of edentulous ridges recorded from multidetector row computed tomography (MDCT) images obtained by a previously untested ultra-low dose in combination with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Methods Three cadavers were imaged using a reference protocol with a standard dose and FBP (volume CT dose index (CTDIvol): 29.4 mGy) and two ultra-low-dose protocols, LD1 and LD2 (CTDIvol: 0.53 and 0.29 mGy). All test examinations were reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. Linear measurements from the images of the edentulous ridges recorded from the test protocols were compared with those from the reference using a one-sample t test, Bland–Altman plots, and linear regression. Statistical significance was set at a p value of 0.05. Results The one-sample t test demonstrated a statistically significant difference between the measurements from the reference protocol and all test protocols. The difference was not clinically significant for the following three test protocols: LD1/FBP, LD1/ASIR 50, and LD2/FBP. Bland–Altman plots with linear regression showed no systematic variation between the measurements obtained with the reference protocol and these three test protocols. Conclusions The lowest-dose protocol to demonstrate comparable measurements with a standard MDCT dose was CTDIvol 0.29 mGy with FBP. These results must be considered with caution for areas of the jaws with thin cortication. The results in areas of thin cortication should be verified by studies with larger sample sizes at such areas and comparison with true gold standard measurements.