Elie Saghbiny

Dr. Elie Saghbiny


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
LLL. Leblanc
L. Leblanc
ESElie Saghbiny
Elie Saghbiny
JSJ. Da Silva
J. Da Silva
AHA. Harlé
A. Harlé
SVS. Vafadar
S. Vafadar
BTBrahim Tamadazte
Brahim Tamadazte
Precise pedicle screw placement is imperative for a range of spinal procedures demanding exact geometric alignment while also carrying inherent risks. The literature reports a complication rate in the case of screw mispositioning of up to 18%. To increase the accuracy of pedicle screw placement, we developed a robotic setup and a breach detection algorithm that could detect a possible perforation of the spinal canal. The robotic setup includes a robotic arm, a drilling system, and specific sensors, e.g., electrical conductivity at the drill bit's tip. The breach detection algorithm consists of a Bayesian-based method providing online and real-time analysis of the electrical conductivity signal to predict a breach. The robotic setup and the perforation detection algorithm were assessed in two ex-vivo experiments. First, data collection was performed by drilling 80 fresh pig vertebrae pedicles, followed by precise data labeling by a surgeon. The evaluation of the proposed algorithm was conducted numerically. Finally, the assessment was performed online by automatically drilling into pedicles in conditions similar to the operating room. The results demonstrated that the algorithm could predict perforations and prevent the robotic setup from going through in 100% of 24 drilled vertebrae. Results demonstrate that using electrical conductivity combined with a robotic setup allows the detection of imminent perforations of the spinal canal during pedicle drilling. This was the first study to evaluate spinal canal perforation detection during ex-vivo pig pedicle drilling.

23 April 2025 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
LBLorie Bellity
Lorie Bellity
AMAlain Masquelet
Alain Masquelet
ESElie Saghbiny
Elie Saghbiny
HGHelena Guerra
Helena Guerra
RGRomain Guedj
Romain Guedj
FFFrank Fitoussi
Frank Fitoussi

11 July 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
ESElie Saghbiny
Elie Saghbiny
LLL. Leblanc
L. Leblanc
AHA. Harlé
A. Harlé
CBC. Bobbio
C. Bobbio
RVRaphaël Vialle
Raphaël Vialle
BTBrahim Tamadazte
Brahim Tamadazte
The accurate placement of pedicle screws is crucial for various spinal interventions, demanding precise geometric alignment while carrying inherent risks. Studies show that the rate of complications can reach up to 18% in case of imprecise placement of pedicle screws. To enhance the precision and safety of pedicle screw placement, we have developed a robotic system equipped with several sensors and paired with a breach detection algorithm capable of identifying potential breaches in the spinal canal. The breach detection algorithm was conceptualized through an analysis of the cutting torque of the drill system. An ex-vivo experiment was conducted to assess the effectiveness of the developed robotic solution and breach detection algorithm. The data (e.g., cutting torque, position, velocity, etc.) used during the validation were collected by drilling 80 pedicles in fresh porcine vertebrae. The results demonstrated that the proposed algorithm could predict breaches in 96.42% of cases, i.e., the distance between the detected point (drilling stop) and the point of the breach is within 2 mm. In a single instance, the detection occurred earlier than anticipated due to the trajectory being oriented significantly medially, resulting in an initial interaction with the cortical bone at an earlier point.

7 November 2023 in Advances in Orthopedics
Verified
Journal Article
Open access
PDF file
ESElie Saghbiny
Elie Saghbiny
JSJimmy Da Silva
Jimmy Da Silva
CCCelia Chaimi
Celia Chaimi
TCThibault Chandanson
Thibault Chandanson
RVRaphaël Vialle
Raphaël Vialle
Introduction. Pedicle screw placement is a common procedure in spinal surgery. The misplacement rate with lateral and medial cortical perforation is 511. Several techniques are used to decrease this rate. Many studies proved that electrical conductivity increases accuracy during pedicle screw placement but no study has interpreted conductivity values. Methods. The data are collected from patients operated for scoliosis in a single university hospital. After the posterior surgical approach is made, each pedicle is prepared classically. Instead of the classic curved pedicle probe, the surgeon uses a probe with the same shape that measures the conductivity at its tip. Conductivity values are recorded through a Bluetooth application. Each pedicle trajectory is then qualified after manual palpation with a feeler. A trajectory is qualified as optimal when palpation shows a bone tunnel without any breach, breached when there was a breach, and a modification of the probe direction was needed. A trajectory that does not meet the abovementioned definitions is excluded from the statistical analysis. Results. 21 patients with 457 pedicles are recorded. The average age of the population is 14.71±1.86years. 17 patients (81) have idiopathic adolescent scoliosis. One patient has Rett syndrome, one has hypotonia, one has cerebral palsy, and one has congenital malformation. The depth of the instrument is measured semiautomatically. This technique is validated when compared with the manual technique using the BlandAltman agreement method (mean differences=0.279mm, upper limit=2.2mm, and lower limit=2.7mm) and Deming regression (slope=1.06±0.004). Conclusion. This study establishes a protocol to collect electrical conductivity signals in spine surgery with synchronization to the depth of the instrument. Real-time conductivity signal feedback alerts the surgeon of a probable breach in the spinal canal, so he can change the direction of the pedicle aim.

17 September 2025 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Open access
VNVirginie Nguyen-Khac
Virginie Nguyen-Khac
ASAnne-Laure Simon
Anne-Laure Simon
BIBrice Ilharreborde
Brice Ilharreborde
LGLaurent Gajny
Laurent Gajny
FFFranck Fitoussi
Franck Fitoussi
MBManon Bachy
Manon Bachy
Over the past decade, the use of patient-specific instrumentation (PSI) has increased exponentially as a means of improving surgical precision. In pediatric orthopedics, its adoption is more recent and differs from adult applications due to the unique characteristics of pediatric deformities and anatomical constraints, particularly the need to preserve the physis. This study aimed to assess the reliability and accuracy of PSI in performing lower limb long bone osteotomies in children. Planned corrections are comparable to the achieved corrections. This bicentric retrospective study included all PSI-assisted lower limb osteotomies performed since 2021. PSI guides were developed using bilateral CT scans. Demographic data, clinical outcomes at the final follow-up, and any complications were recorded. In all cases, postoperative three-dimensional (3D) reconstruction was performed using low-dose biplanar stereo radiography (EOS) and compared to the preoperative CT-based surgical plan. For each osteotomy, 3D measurements of the primary correction in all three planes were analyzed. Postoperative reliability was defined as the difference between the preoperative plan and the achieved correction (Δ angle). A threshold of ±3 ° was used to assess the accuracy of PSI. Eighteen patients (21 osteotomies, mean age 14.6 ± 3.4 years) were included: 52% femoral (n = 11) and 48% tibial (n = 10). At a mean follow-up of 10 ± 5 months, one intraoperative and three postoperative complications were observed. Two patients reported residual pain at the final follow-up. Planned corrections ranged from 9 ° to 85 °, with 62% exceeding 15 °. The mean Δ angle was 11 °, with no significant difference overall (p = 0.06), but a trend toward undercorrection was observed in cases with planned corrections >15 ° (p = 0.03). The use of PSI in pediatric lower limb osteotomies tends to result in undercorrection compared to the planification, particularly in case of severe deformity. This may be explained by the greater magnitude of corrections typically required in pediatric patients compared to adults. Although these findings require confirmation through larger cohorts and 3D postoperative analysis, they should be considered when using PSI in pediatric lower limb osteotomies. III; Retrospective case-control study.

26 April 2024 in Journal of Surgical Education
Verified
Journal Article
Closed access
TLTristan Langlais
Tristan Langlais
RPRaphaël Pietton
Raphaël Pietton
ACAdeline Cambon-Binder
Adeline Cambon-Binder
FCFleur Cohen
Fleur Cohen
RVRaphaël Vialle
Raphaël Vialle
LMLaura Marie-Hardy
Laura Marie-Hardy