Lihui Ma

Dr. Lihui Ma


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2024 in Processes
Verified
Journal Article
Open access
PDF file
ZHZhuo Han
Zhuo Han
LMLihui Ma
Lihui Ma
XLXiaowei Li
Xiaowei Li
HZHaoran Zhu
Haoran Zhu
WLWei Li
Wei Li
RGRui Guo
Rui Guo
Blending with light oil is a commonly used and reliable method of crude oil transportation, and the blending ratio is a crucial operating parameter in determining the safe and efficient operation of the pipeline. In this paper, in-house flow and deposition experiments are used to evaluate the flow and deposition characteristics of crude oils with varying blending ratios. The results show that (1) blending with light oil basically does not affect the shape of the DSC curve of crude oil; (2) blending with light oil will not eliminate the thermal treatment effect, and the mixed oil flowability still remains highly dependent on the thermal treatment temperature; (3) blending with light oil can greatly decrease the abnormal point and oil viscosity, in which the low-temperature viscosity decreases more significantly; and (4) a wax deposition model of mixed oil is obtained through the fitting of Huang’s model, where the blending ratio is a crucial factor in the determination of the model parameters k, m, and n.

1 January 2023 in Fluid Dynamics & Materials Processing
Verified
Journal Article
Open access
PDF file
XNXiaowei Nie
Xiaowei Nie
LMLihui Ma
Lihui Ma
YXYiqiu Xu
Yiqiu Xu
DSDong Sun
Dong Sun
WZWeibo Zheng
Weibo Zheng
YLYunfei Li
Yunfei Li
An experimental study was conducted to investigate the properties of stratified regular or wavy two-phase flow in two parallel separators located after a manifold. A total of 103 experiments with various gas and liquid velocity combinations in three inlet pipes were conducted, including 77 groups of outlet pipe resistance symmetry and 26 groups of outlet pipe resistance asymmetry trials. The experimental results have revealed that when the gas-liquid flow rate is low, the degree of uneven splitting is high, and “extreme” conditions are attained. When the superficial gas velocity is greater than that established in the extreme case, the direction of the liquid-phase displacement is reversed, while that of the gas remains unchanged. Thus, the degree of gas phase bias tends to be mitigated with an increase in the gas velocity, while the uneven splitting degree of liquid approaches 10%. Finally, varying the gas-phase outlet pipe resistance is shown to effectively change the gas-liquid two-phase flow distribution.

10 June 2026 in Processes
Verified
Journal Article
Open access
PDF file
XWXinwei Wang
Xinwei Wang
HWHuiqin Wu
Huiqin Wu
DSDong Sun
Dong Sun
LMLihui Ma
Lihui Ma
PZPan Zhang
Pan Zhang
RLriyi lin
riyi lin
During heavy oil development, the gathering and transportation of low-temperature wellhead-produced fluids are often accompanied by high viscosity, pipe-wall deposition, and high flow resistance, threatening the continuous and stable operation of gathering systems. Existing studies on wellhead heating mainly focus on overall steady-state heating performance, while variable-flow heat transfer and start–stop control in local heating systems remain insufficiently explored. This study aims to evaluate the steady-state heating capacity, transient thermal response, and start–stop control performance of a localized electric heating section under variable-flow conditions. A 3D fluid–solid-coupled heat-transfer model of the heating element, pipe wall, and internal fluid was developed using COMSOL Multiphysics. The steady-state temperature field, transient heating and cooling behavior, and start–stop control characteristics were analyzed under different flow rates. The results show that, at a heating power of 15 kW and a flow rate of 20 m3/d, the maximum outer-wall temperature reached 564 K, and the average outlet fluid temperature reached 308.83 K, indicating effective heating performance. As the flow rate increased from 10 m3/d to 30 m3/d, the maximum pipe-wall temperature and fluid temperature rise both decreased, whereas the average fluid-side heat-transfer coefficient increased from approximately 700 W/(m2·K) to 1800 W/(m2·K), demonstrating enhanced convective heat transfer. Under a dual-threshold control strategy of 463.15–483.15 K, the system maintained the target temperature near 473.15 K under all tested conditions, while the load factor increased from 37.83% to 86.15%. These findings provide theoretical references and engineering support for optimizing power configuration and improving temperature control strategies in local heating systems for wellhead-produced fluids.