Background: Fetal magnetocardiography ( fMCG ) is a highly effective technique for evaluation of fetuses with life‐threatening arrhythmia, but its dissemination has been constrained by the high cost and complexity of Superconducting Quantum Interference Device (SQUID) instrumentation. Optically pumped magnetometers ( OPM s) are a promising new technology that can replace SQUID s for many applications. This study compares the performance of an fMCG system, utilizing OPM s operating in a person‐sized magnetic shield, to that of a conventional fMCG system, utilizing SQUID magnetometers operating in a magnetically shielded room. Methods and Results: fMCG recordings were made in 24 subjects using the SQUID system with the mother lying supine in a magnetically shielded room and the OPM system with the mother lying prone in a person‐sized, cylindrical shield. Signal‐to‐noise ratios of the OPM and SQUID recordings were not statistically different and were adequate for diagnostic purposes with both technologies. Although the environmental noise was higher using the small open‐ended shield, this was offset by the higher signal amplitude achieved with prone positioning, which reduced the distance between the fetus and sensors and improved patient comfort. In several subjects, fMCG provided a differential diagnosis that was more precise and/or definitive than was possible with echocardiography alone. Conclusions: The OPM ‐based system was portable, improved patient comfort, and performed as well as the SQUID ‐based system at a small fraction of the cost. Electrophysiological assessment of fetal rhythm is now practical and will have a major impact on management of fetuses with long QT syndrome and other life‐threatening arrhythmias.

21 January 2003 in Circulation
Verified
Journal Article
Closed access
PDF file
RWRonald Wakai
Ronald Wakai
JSJ.F. Strasburger
J.F. Strasburger
ZLZ. Li
Z. Li
BDB.J. Deal
B.J. Deal
NGN.L. Gotteiner
N.L. Gotteiner
Background— Using fetal magnetocardiography (fMCG), we characterize for the first time the electrophysiological patterns of initiation and termination of reentrant fetal supraventricular tachycardia (SVT), the most common form of life-threatening fetal arrhythmia. Methods and Results— In contrast to the expectation that reentrant SVT is initiated by spontaneous premature atrial contractions (PACs) and is terminated by spontaneous block, 5 distinct patterns of initiation and 4 patterns of termination were documented, with the most common patterns of initiation involving reentrant PACs. Waveform morphology and timing, including QRS and ventriculoatrial interval, were assessed. This enabled detection of such phenomena as Wolff-Parkinson-White syndrome, QRS aberrancy, and multiple reentrant pathways that were crucial for defining the rhythm patterns. In addition, fMCG actocardiography revealed an unexpectedly strong association between fetal trunk movement and the initiation and termination of SVT, suggesting that autonomic influences play a key role. Conclusions— This study demonstrates that the patterns of initiation and termination of fetal SVT are more diverse than is generally believed and that the most common patterns of initiation involve reentrant PACs. The ability to discern such patterns can help elucidate the underlying mechanisms and guide antiarrhythmic drug therapy. fMCG provides a noninvasive means of analyzing complex tachyarrhythmia in utero, with efficacy approaching that of postnatal electrocardiographic rhythm monitoring.

12 November 2013 in Circulation
Verified
Journal Article
Closed access
PDF file
BCBettina F. Cuneo
Bettina F. Cuneo
JSJanette F. Strasburger
Janette F. Strasburger
SYSuhong Yu
Suhong Yu
HHHitoshi Horigome
Hitoshi Horigome
THTakayoshi Hosono
Takayoshi Hosono
RWRonald Wakai
Ronald Wakai
Background—: The electrophysiology of long QT syndrome (LQTS) in utero is virtually unstudied. Our goal here was to evaluate the efficacy of fetal magnetocardiography (fMCG) for diagnosis and prognosis of fetuses at risk of LQTS. Methods and Results—: We reviewed the pre/postnatal medical records of 30 fetuses referred for fMCG because of a family history of LQTS (n=17); neonatal/childhood sudden cardiac death (n=3), or presentation of prenatal LQTS rhythms (n=12): 2° atrioventricular block, ventricular tachycardia, heart rate < 3 rd percentile. We evaluated heart rate and reactivity, cardiac time intervals, T-wave characteristics, and initiation/termination of Torsade de Pointes, and compared these with neonatal ECG findings. After birth, subjects were tested for LQTS mutations. Based on accepted clinical criteria, 21 subjects (70%; 9 KCNQ1, 5 KCNH2, 2 SCN5A, 2 other, 3 untested) had LQTS. Using a threshold of corrected QT= 490 ms, fMCG accurately identified LQTS fetuses with 89% (24/27) sensitivity and 89% (8/9) specificity in 36 sessions. Four fetuses (2 KCNH2 and 2 SCN5A), all with corrected QT ≥ 620 ms, had frequent episodes of Torsade de Pointes, which were present 22–79% of the time. Although some episodes initiated with a long-short sequence, most initiations showed QRS aberrancy and a notable lack of pause dependency. T-wave alternans was strongly associated with severe LQTS phenotype. Conclusions—: Corrected QT prolongation (≥490 ms) assessed by fMCG accurately identified LQTS in utero; extreme corrected QT prolongation (≥620 ms) predicted Torsade de Pointes. FMCG can play a critical role in the diagnosis and management of fetuses at risk of LQTS.

1 January 2008 in JACC
Verified
Journal Article
Closed access
HZHui Zhao
Hui Zhao
BCBettina F. Cuneo
Bettina F. Cuneo
JSJanette F. Strasburger
Janette F. Strasburger
JHJames C. Huhta
James C. Huhta
NGNina L. Gotteiner
Nina L. Gotteiner
RWRonald Wakai
Ronald Wakai

1 November 2004 in Experimental Neurology
Verified
Journal Article
Closed access
RWRonald Wakai
Ronald Wakai

29 July 2022 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
AWAnnette Wacker‐Gussmann
Annette Wacker‐Gussmann
JSJanette F Strasburger
Janette F Strasburger
RWRonald Wakai
Ronald Wakai
Background: Fetal echocardiography has been the mainstay of fetal arrhythmia diagnosis; however, fetal magnetocardiography (fMCG) has recently become clinically available. We sought to determine to what extent fMCG contributed to the precision and accuracy of fetal arrhythmia diagnosis and risk assessment, and in turn, how this altered pregnancy management. Methods and Results: We reviewed fMCG tracings and medical records of 215 pregnancies referred to the Biomagnetism Laboratory, UW‐Madison, over the last 10 years, because of fetal arrhythmia or risk of arrhythmia. We compared referral diagnosis and treatment with fMCG diagnosis using a rating scale and restricted our review to the 144 subjects from the tachycardia, bradycardia/AV block, and familial long QT syndrome categories. Additional fMCG findings beyond those of the referring echocardiogram, or an alternative diagnosis were seen in 117/144 (81%), and 81 (56%) were critical changes. Eight (5.5%) had resolution of arrhythmia before fMCG. At least moderate changes in management were seen in 109/144 (76%) fetuses, of which 35/144 (24%) were major. The most diverse fMCG presentation was long QT syndrome, present in all 3 referral categories. Four of 5 stillbirths were seen with long QT syndrome. Nine fetuses showed torsades de pointes ventricular tachycardia, of which only 2 were recognized before fMCG. Conclusions: FMCG has a significant impact on prenatal diagnosis and management of arrhythmias or familial arrhythmia risk, which cannot be fully met by existing technology. The combination of fMCG and fetal echocardiography in fetal care centers will be needed in the future to optimize care.