Purpose: Suspensory devices are extensively used in the management of anterior cruciate ligament (ACL) tear. They include fixed- and adjustable-loop devices. There are only a few studies comparing the efficacy of these two devices in the available literature. Therefore, the aim of this study is to compare clinical outcomes between the adjustable-loop device (group I) and fixed-loop device (group II). Materials and methods: This was a prospective randomized study. Both groups were equivalent in demographic, preoperative, and intraoperative variables. Twenty-three patients underwent femoral side graft fixation with adjustable-loop and 20 with fixed-loop devices. Four patients were lost to follow-up. Assessment of clinical outcome was done with International Knee Documentation Committee (IKDC) score, Lysholm score, and knee stability tests (Lachman test and pivot shift test). Patient evaluation was performed preoperatively and finally postoperatively 2 years after surgery. Results: Postoperative IKDC scores of group I and II were 91.9 ± 3.6 and 91.5 ± 3.6, respectively, and Lysholm scores were 91.0 ± 3.6 and 91.4 ± 3.5, respectively, after 2 years; however, the difference in the outcomes was statistically insignificant (p > 0.05). Twenty patients (87%) in group I and 17 patients (85%) in group II had a negative Lachman test (p = 0.8). Twenty-two patients (95.7%) in group I and 19 patients (95%) in group II had a negative pivot shift test (p = 0.9). Conclusion: ACL reconstruction with fixed- and adjustable-loop suspensory devices for graft fixation gives equivalent and satisfactory clinical results. Level of evidence: 1.
Arthroscopic anatomic anterior cruciate ligament reconstruction (ACLR) is the gold standard treatment for an ACL tear and requires the use of fixed or adjustable-loop devices to fix a femoral-side graft. Although the adjustable mechanism is designed to provide one-way tensioning, there is a concern that the adjustable loop will loosen and lengthen during cyclic loads, creating graft laxity. The present paper is a retrospective study of patients who underwent ACLR with the fixation of a hamstring graft with an adjustable loop on the femoral side from November 2016 to October 2018. The knee’s functional outcome was evaluated using an International Knee Documentation Committee (IKDC) score, Lysholm score, Lachman test, and pivot shift test. The patients were assessed preoperatively and finally postoperatively after two years of surgery. Thirty-two patients were analyzed. Significant improvement was obtained in the final clinical outcome of the patients. Twenty-seven patients (84.4%) were Lachman negative, and twenty-eight patients (87.5%) were pivot shift test negative, the mean Lysholm score was 96.91, and the IKDC score was 91.47 (p < 0.001). There was no infection, graft failure, or flexion restriction. Arthroscopic ACLR with an adjustable-loop suspensory device is a successful fixation method for femoral-side graft fixation and offers a similar functional outcome as with fixed-loop devices.