Guy Dumont

Dr. Guy Dumont

orcid

Research Focus & Metrics

Academic Career Length

50Years (1977-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2012 in Physiological Measurement
Verified
Journal Article
Closed access
BMBehnam Molavi
Behnam Molavi
GDGuy Dumont
Guy Dumont
Functional near-infrared spectroscopy (fNIRS) is a powerful tool for monitoring brain functional activities. Due to its non-invasive and non-restraining nature, fNIRS has found broad applications in brain functional studies. However, for fNIRS to work well, it is important to reduce its sensitivity to motion artifacts. We propose a new wavelet-based method for removing motion artifacts from fNIRS signals. The method relies on differences between artifacts and fNIRS signal in terms of duration and amplitude and is specifically designed for spike artifacts. We assume a gaussian distribution for the wavelet coefficients corresponding to the underlying hemodynamic signal in detail levels and identify the artifact coefficients using this distribution. An input parameter controls the intensity of artifact attenuation in trade-off with the level of distortion introduced in the signal. The method only modifies wavelet coefficients in levels adaptively selected based on the degree of contamination with motion artifact. To demonstrate the feasibility of the method, we tested it on experimental fNIRS data collected from three infant subjects. Normalized mean-square error and artifact energy attenuation were used as criteria for performance evaluation. The results show 18.29 and 16.42 dB attenuation in motion artifacts energy for 700 and 830 nm wavelength signals in a total of 29 motion events with no more than -16.7 dB distortion in terms of normalized mean-square error in the artifact-free regions of the signal.

1 July 2013 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
WKWalter Karlen
Walter Karlen
SRS. Raman
S. Raman
JAJ Mark Ansermino
J Mark Ansermino
GDGuy Dumont
Guy Dumont
We present a novel method for estimating respiratory rate in real time from the photoplethysmogram (PPG) obtained from pulse oximetry. Three respiratory-induced variations (frequency, intensity, and amplitude) are extracted from the PPG using the Incremental-Merge Segmentation algorithm. Frequency content of each respiratory-induced variation is analyzed using fast Fourier transforms. The proposed Smart Fusion method then combines the results of the three respiratory-induced variations using a transparent mean calculation. It automatically eliminates estimations considered to be unreliable because of detected presence of artifacts in the PPG or disagreement between the different individual respiratory rate estimations. The algorithm has been tested on data obtained from 29 children and 13 adults. Results show that it is important to combine the three respiratory-induced variations for robust estimation of respiratory rate. The Smart Fusion showed trends of improved estimation (mean root mean square error 3.0 breaths/min) compared to the individual estimation methods (5.8, 6.2, and 3.9 breaths/min). The Smart Fusion algorithm is being implemented in a mobile phone pulse oximeter device to facilitate the diagnosis of severe childhood pneumonia in remote areas.

1 January 1992 in IEEE Transactions on Systems, Man, and Cybernetics
Verified
Journal Article
Closed access
KKK. Kristinsson
K. Kristinsson
GDGuy Dumont
Guy Dumont

1 December 2013 in SLEEP
Verified
Journal Article
Closed access
PBPhilippe Boudreau
Philippe Boudreau
WYWei-Hsien Yeh
Wei-Hsien Yeh
GDGuy Dumont
Guy Dumont
DBDiane B. Boivin
Diane B. Boivin
S and full research articles published in SLEEP, the official journal of the APSS. Sleep and sleep disorder scientific findings.

14 June 2010 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AZAli Shahidi Zandi
Ali Shahidi Zandi
MJManouchehr Javidan
Manouchehr Javidan
GDGuy Dumont
Guy Dumont
RTReza Tafreshi
Reza Tafreshi
A novel wavelet-based algorithm for real-time detection of epileptic seizures using scalp EEG is proposed. In a moving-window analysis, the EEG from each channel is decomposed by wavelet packet transform. Using wavelet coefficients from seizure and nonseizure references, a patient-specific measure is developed to quantify the separation between seizure and nonseizure states for the frequency range of 1-30 Hz. Utilizing this measure, a frequency band representing the maximum separation between the two states is determined and employed to develop a normalized index, called combined seizure index (CSI). CSI is derived for each epoch of every EEG channel based on both rhythmicity and relative energy of that epoch as well as consistency among different channels. Increasing significantly during ictal states, CSI is inspected using one-sided cumulative sum test to generate proper channel alarms. Analyzing alarms from all channels, a seizure alarm is finally generated. The algorithm was tested on scalp EEG recordings from 14 patients, totaling 75.8 h with 63 seizures. Results revealed a high sensitivity of 90.5% , a false detection rate of 0.51 h-1 and a median detection delay of 7 s. The algorithm could also lateralize the focus side for patients with temporal lobe epilepsy.

1 January 2013 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AZAli Shahidi Zandi
Ali Shahidi Zandi
RTReza Tafreshi
Reza Tafreshi
MJManouchehr Javidan
Manouchehr Javidan
GDGuy Dumont
Guy Dumont
A novel patient-specific seizure prediction method based on the analysis of positive zero-crossing intervals in scalp electroencephalogram (EEG) is proposed. In a moving-window analysis, the histogram of these intervals for the current EEG epoch is computed, and the values corresponding to specific bins are selected as an observation. Then, the set of observations from the last 5 min is compared with two reference sets of data points (preictal and interictal) through novel measures of similarity and dissimilarity based on a variational Bayesian Gaussian mixture model of the data. A combined index is then computed and compared with a patient-specific threshold, resulting in a cumulative measure which is utilized to form an alarm sequence for each channel. Finally, this channel-based information is used to generate a seizure prediction alarm. The proposed method was evaluated using ~ 561 h of scalp EEG including a total of 86 seizures in 20 patients. A high sensitivity of 88.34% was achieved with a false prediction rate of 0.155 h-1 and an average prediction time of 22.5 min for the test dataset. The proposed method was also tested against a Poisson-based random predictor.