Nearly collimated atomic beam is of interest for a variety of experiments. This article reports a simple way of modifying the atomic beam distribution using a dark wall oven and describes detailed study of outcoming atoms’ spatial distribution. A simple design is obtained by employing the fact that inhomogeneous thermal distribution along a capillary results due to its partial resistive heating. Based on this phenomenon, we have designed a dark wall oven consisting of a reservoir, collimator, and cold absorber at the exit end of atoms, where all three are fabricated out of a single stainless steel capillary. The nearly collimated spatial distribution of the atoms resulting due to the absorber eliminating the atoms diverging above a certain angle is modeled and experimentally verified. A divergence as minimum as 1.2(1)° corresponding to a half angle θ1/2 = 0.9(1)° is measured at an oven temperature of 250 °C that produces an atomic flux of about 8 × 109 atoms s−1. Total flux as estimated using our measured spatial distribution of atoms matches well with the numerically simulated values of it for the dark wall oven.
Capacitive, inductive and resistive loads of an ion-trap system, which can be modelled as LCR circuits, are important to know for building a high accuracy experiment. Accurate estimation of these loads is necessary for delivering the desired radio frequency (RF) signal to an ion trap via an RF resonator. Of particular relevance to the trapped ion optical atomic clock, determination of these loads lead to accurate evaluation of the Black-Body Radiation (BBR) shift resulting from the inaccurate machining of the ion-trap itself. We have identified different sources of these loads and estimated their values using analytical and finite element analysis methods, which are found to be well in agreement with the experimentally measured values. For our trap geometry, we obtained values of the effective inductive, capacitive and resistive loads as: 3.1 μH, 3.71 (1) μH, 3.68 (6) μH; 50.4 pF, 51.4 (7) pF, 40.7 (2) pF; and 1.373 Ω, 1.273 (3) Ω, 1.183 (9) Ω by using analytical, numerical and experimental methods, respectively. The BBR shift induced by the excess capacitive load arising due to machining inaccuracy in the RF carrying parts has been accurately estimated, which results to a fractional frequency shift of 6.6 × 10−17 for an RF of 1 kV at 2π × 15 MHz and with ±10 μm machining inaccuracy. This needs to be incorporated into the total systematic uncertainty budget of a frequency standard as it is about one order of magnitude higher than the present precision of the trapped ion optical clocks.
Precise transfer of time and frequency signals over long distances as well as clock synchronization to an ultra‐stable reference are very crucial for many of the technological applications as well as for advanced scientific research. These reinforces a wide range of applications such as navigation, power grid management, mobile communication, and so on. In order to compare the performances of two highly stable and accurate atomic clocks, it is desirable that the link between the two clocks, that is, the transmission link has higher level of stability than those clocks. This article describes establishment of an ultra‐stable optical fiber link employing White Rabbit network for transfer of time and frequency signals and also for comparing performance of atomic clocks. Utilizing this link, time signals have been transferred within an uncertainty of ±130 ps at ambient temperature (30°C–40°C) and the instability of the link in terms of modified Allan‐deviation reaches to ∼10−16 within one day of integration time.
We report the frequency stabilization of an external cavity diode laser (ECDL) to a reference molecular iodine (I2) transition at 13,531.18 cm−1 (739.03382 nm). Using the Modulation Transfer Spectroscopy (MTS) method for the highly sensitive detection of weak absorption signals, the Doppler-free absorption peaks of I2 corresponding to the hot band transition R(78) (1–11) are resolved. The ECDL’s frequency is stabilized with respect to one of the lines lying within the reference absorption band. For this, the iodine vapor cell is heated to 450 °C and the corresponding circularly polarized pump and probe beam powers are maintained at 10 mW and 1 mW, respectively, to avoid power broadening. The short (100 ms) and long-term (50 h) linewidths of the frequency stabilized laser are measured to be 0.75(3) MHz and 0.5(2) MHz, respectively, whereas the natural linewidth of the specific I2-transitions lie within a range of tens of MHz.