Glucose sensors based blood glucose detection are of great significance for the diagnosis and treatment of diabetes because diabetes has aroused wide concern in the world. In this study, bovine serum albumin (BSA) was used to cross-link glucose oxidase (GOD) on a glassy carbon electrode (GCE) modified by a composite of hydroxy fullerene (HFs) and multi-walled carbon nanotubes (MWCNTs) and protected with a glutaraldehyde (GLA)/Nafion (NF) composite membrane to prepare a novel glucose biosensor. The modified materials were analyzed by UV-visible spectroscopy (UV-vis), transmission electron microscopy (TEM), and cyclic voltammetry (CV). The prepared MWCNTs-HFs composite has excellent conductivity, the addition of BSA regulates MWCNTs-HFs hydrophobicity and biocompatibility, and better immobilizes GOD on MWCNTs-HFs. MWCNTs-BSA-HFs plays a synergistic role in the electrochemical response to glucose. The biosensor shows high sensitivity (167 μA·mM−1·cm−2), wide calibration range (0.01–3.5 mM), and low detection limit (17 μM). The apparent Michaelis–Menten constant is 119 μM. Additionally, the proposed biosensor has good selectivity and excellent storage stability (120 days). The practicability of the biosensor was evaluated in real plasma samples, and the recovery rate was satisfactory.
Rutin is a flavonoid glycoside compound, which is mainly transported via the blood circulation system in the human body. The monitoring of the blood concentration of rutin is of great significance in many fields such as pharmacology and pharmacokinetics. In this work, a biosensor based on multi-walled carbon nanotubes (MWCNTs), cetyltrimethylammonium bromide (CTAB), hydroxyl fullerenes (HFs), and laccase (Lac) nanocomposite-modified glassy carbon electrodes was constructed. The modified materials were characterized with a transmission electron microscope (TEM), cyclic voltammograms (CV), and electrochemical impedance spectroscopy (EIS). CTAB is used to disperse MWCNTs and improve hydrophilicity and biocompatibility of MWCNTs, while the use of Lac can enhance the oxidation of catechol structure in rutin, thus significantly improving the sensitivity and selectivity of the modified electrode. Linear sweep voltammetry (LSV) studies showed that the determination linear ranges of rutin were 0.1 µmol L−1 to 2 µmol L−1 and 2 µmol L−1 to 11 µmol L−1, with the determination limits of 30 nmol L−1 and 95.5 nmol L−1, respectively. The proposed biosensor can be used to detect rutin tablets and serum samples with high recovery, which indicates a good accuracy of this method, and the results are consistent with those measured by the traditional ultra-high performance liquid chromatography (UHPLC) method. Hence, this biosensor has potential practical application value in rutin drug quality testing and clinical blood drug concentration monitoring.
Rutin is a natural antioxidant flavonoid compound with anti-inflammatory, antioxidant, and antiviral effects that is used to prepare drugs with wide application in clinical treatment. Therefore, the quantitative detection of rutin has important practical significance. In this work, a novel electrochemical sensor based on glassy carbon electrodes (GCEs) modified with sodium carboxymethylcellulose (CMC), multi-walled carbon nanotubes (MWCNTs), and 1-butyl-3-methylimid (ionic liquid, IL) was developed for the super-sensitive detection of the flavonoid rutin. The properties of these modified materials were analyzed by transmission electron microscope (TEM), cyclic voltammograms (CVs), and electrochemical-impedance spectroscopy (EIS). CMC was used to disperse MWCNTs to further enhance their hydrophilicity and biocompatibility. The modified MWCNTs improved the sensitivity of rutin detection. The square-wave voltammetry (SWV) technique showed that the linear range of rutin concentration determination was 0.01 μM to 1 µM and 1 µM to 10 µM. The minimum concentration detection of rutin was 0.83 nM and 6.6 nM, respectively. The proposed sensor presented good selectivity for rutin and successfully analyzed rutin content in the pharmaceutical rutin tablets. These results are consistent with those measured by ultra-high-performance liquid chromatography (UHPLC). Therefore, this sensor has latent application value in the analysis of rutin in food and drug tablets and nutraceutical samples.