Shinichi Terada

Dr. Shinichi Terada


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
TTTomohito Tanaka
Tomohito Tanaka
RNRuri Nishie
Ruri Nishie
SUshoko ueda
shoko ueda
SMShunsuke Miyamoto
Shunsuke Miyamoto
SHSousuke Hashida
Sousuke Hashida
MOMasahide Ohmichi
Masahide Ohmichi
Background: Patient-derived xenograft (PDX) models have been a focus of attention because they closely resemble the tumor features of patients and retain the molecular and histological features of diseases. They are promising tools for translational research. In the current systematic review, we identify publications on PDX models of cervical cancer (CC-PDX) with descriptions of main methodological characteristics and outcomes to identify the most suitable method for CC-PDX. Methods: We searched on PubMed to identify articles reporting CC-PDX. Briefly, the main inclusion criterion for papers was description of PDX created with fragments obtained from human cervical cancer specimens, and the exclusion criterion was the creation of xenograft with established cell lines. Results: After the search process, 10 studies were found and included in the systematic review. Among 98 donor patients, 61 CC-PDX were established, and the overall success rate was 62.2%. The success rate in each article ranged from 0% to 75% and was higher when using severe immunodeficient mice such as severe combined immunodeficient (SCID), nonobese diabetic (NOD) SCID, and NOD SCID gamma (NSG) mice than nude mice. Subrenal capsule implantation led to a higher engraftment rate than orthotopic and subcutaneous implantation. Fragments with a size of 1–3 mm3 were suitable for CC-PDX. No relationship was found between the engraftment rate and characteristics of the tumor and donor patient, including histology, staging, and metastasis. The latency period varied from 10 days to 12 months. Most studies showed a strong similarity in pathological and immunohistochemical features between the original tumor and the PDX model. Conclusion: Severe immunodeficient mice and subrenal capsule implantation led to a higher engraftment rate; however, orthotopic and subcutaneous implantation were alternatives. When using nude mice, subrenal implantation may be better. Fragments with a size of 1–3 mm3 were suitable for CC-PDX. Few reports have been published about CC-PDX; the results were not confirmed because of the small sample size.

Verified
Journal Article
Open access
PDF file
STShinichi Terada
Shinichi Terada
TTTomohito Tanaka
Tomohito Tanaka
Hikaru MurakamiHikaru Murakami
Hikaru Murakami
HTHiromitsu Tsuchihashi
Hiromitsu Tsuchihashi
ATAkihiko Toji
Akihiko Toji
MOMasahide Ohmichi
Masahide Ohmichi
Sentinel node biopsy (SNB) is performed worldwide in patients with endometrial cancer (EC). The aim of this study was to evaluate and compare the occurrence rate of lymphatic complications between SNB and pelvic lymphadenectomy (LND) for EC. The medical records of women who underwent SNB or pelvic LND for EC between September 2012 and April 2022 were assessed. A total of 388 patients were enrolled in the current study. Among them, 201 patients underwent SNB and 187 patients underwent pelvic LND. The occurrence rates of lower-extremity lymphedema (LEL) and pelvic lymphocele (PL) were compared between the patients who underwent SNB and those who underwent pelvic LND. The SNB group had a significantly lower occurrence rate of lower-extremity LEL than the pelvic LND group (2.0% vs. 21.3%, p < 0.01). There were no patients who had PL in the SNB group; however, 4 (2.1%) patients in the pelvic LND group had PL. The occurrence rates of lower-extremity LEL and PL were significantly lower in patients who underwent SNB than those who underwent pelvic LND. SNB for EC has a lower risk of lymphatic complications compared to systemic LND.

3 April 2023 in Applied Radiation and Isotopes
Verified
Journal Article
Open access
STShinichi Terada
Shinichi Terada
STSatoshi Tsunetoh
Satoshi Tsunetoh
YTYoshimichi Tanaka
Yoshimichi Tanaka
TTTomohito Tanaka
Tomohito Tanaka
HKHideki Kashiwagi
Hideki Kashiwagi
MOMasahide Ohmichi
Masahide Ohmichi
There are few studies about boron neutron capture therapy (BNCT) for cervical cancer. The present study evaluated the biodistribution of boronophenylalanine (BPA) and the effect of BNCT on cervical cancer cell lines. BPA exposure and neutron irradiation of cervical cancer cell lines resulted in decreased survival fraction compared to irradiation only. In vivo cervical cancer tumor boron concentration was highest at 2.5 h after BPA intraperitoneal administration, and higher than in the other organs. BNCT may be effective against cervical carcinoma.

Verified
Journal Article
Open access
PDF file
TTTomohito Tanaka
Tomohito Tanaka
RNRuri Nishie
Ruri Nishie
SUshoko ueda
shoko ueda
SMShunsuke Miyamoto
Shunsuke Miyamoto
SHSousuke Hashida
Sousuke Hashida
MOMasahide Ohmichi
Masahide Ohmichi
Background: Because patient-derived xenograft (PDX) models resemble the original tumors, they can be used as platforms to find target agents for precision medicine and to study characteristics of tumor biology such as clonal evolution and microenvironment interactions. The aim of this review was to identify articles on endometrial cancer PDXs (EC-PDXs) and verify the methodology and outcomes. Methods: We used PubMed to research and identify articles on EC-PDX. The data were analyzed descriptively. Results: Post literature review, eight studies were selected for the systematic review. Eighty-five EC-PDXs were established from 173 patients with EC, with a total success rate of 49.1%. A 1–10 mm3 fragment was usually implanted. Fresh-fragment implantation had higher success rates than using overnight-stored or frozen fragments. Primary tumors were successfully established with subcutaneous implantation, but metastasis rarely occurred; orthotopic implantation via minced tumor cell injection was better for metastatic models. The success rate did not correspond to immunodeficiency grades, and PDXs using nude mice reduced costs. The tumor growth period ranged from 2 weeks to 13 months. Similar characteristics were observed between primary tumors and PDXs, including pathological findings, gene mutations, and gene expression. Conclusion: EC-PDXs are promising tools for translational research because they closely resemble the features of tumors in patients and retain molecular and histological features of the disease.

16 June 2022 in Cancers
Verified
Journal Article
Open access
PDF file
SMShunsuke Miyamoto
Shunsuke Miyamoto
TTTomohito Tanaka
Tomohito Tanaka
KHKensuke Hirosuna
Kensuke Hirosuna
RNRuri Nishie
Ruri Nishie
SUshoko ueda
shoko ueda
MOMasahide Ohmichi
Masahide Ohmichi
Patient-derived xenograft (PDX) models are useful tools for preclinical drug evaluation, biomarker identification, and personalized medicine strategies, and can be developed by the heterotopic or orthotopic grafting of surgically resected tumors into immunodeficient mice. We report the PDX models of cervical cancer and demonstrate the similarities among original and different generations of PDX tumors. Fresh tumor tissues collected from 22 patients with primary cervical cancer were engrafted subcutaneously into NOD.CB17-PrkdcSCID/J mice. Histological and immunohistochemical analyses were performed to compare primary and different generations of PDX tumors. DNA and RNA sequencing were performed to verify the similarity between the genetic profiles of primary and PDX tumors. Total RNA in extracellular vesicles (EVs) released from primary and PDX tumors was also quantified to evaluate gene expression. The total tumor engraftment rate was 50%. Histologically, no major differences were observed between the original and PDX tumors. Most of the gene mutations and expression patterns related to carcinogenesis and infiltration were similar between the primary tumor and xenograft. Most genes associated with carcinogenesis and infiltration showed similar expression levels in the primary tumor and xenograft EVs. Therefore, compared with primary tumors, PDX models could be potentially more useful for translational research.

Verified
Journal Article
Open access
PDF file
HMHiroshi Maruoka
Hiroshi Maruoka
TTTomohito Tanaka
Tomohito Tanaka
Hikaru MurakamiHikaru Murakami
Hikaru Murakami
HTHiromitsu Tsuchihashi
Hiromitsu Tsuchihashi
ATAkihiko Toji
Akihiko Toji
MOMasahide Ohmichi
Masahide Ohmichi
Ovarian clear cell carcinomas (OCCs) arise from endometriotic cysts that many women develop. Biomarkers for early OCC detection need to be identified. Extracellular vesicles have attracted attention as biomarker carriers. This study aims to identify cancer-specific miRNAs as novel OCC biomarkers using tissue-exudative extracellular vesicles (Te-EVs). Te-EVs were collected from four patients with OCC on one side and a normal ovary on the other side. Microarray analysis was performed to identify cancer-specific miRNAs in Te-EVs. Serum samples obtained before and after surgery from patients with OCC and atypical endometrial hyperplasia (AEH) (controls) were compared using real-time PCR to examine changes in the detected EV miRNA levels. Thirty-seven miRNAs were >2-fold upregulated on the OCC side compared with the normal ovarian side. We selected 17 miRNAs and created specific primers for 12 of these miRNAs. The levels of six EV miRNAs were significantly decreased in postoperative OCC serum compared to those in preoperative OCC serum. In contrast, no significant change was observed between the pre and postoperative values in the control group. We identified OCC tissue-specific miRNAs in the EVs secreted by OCC tissues. These EV miRNAs have potential for use as biomarkers for the early diagnosis and detection of OCC.