Fernando Rodrigo Silva Aciares

Dr. Fernando Rodrigo Silva Aciares


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Aquaculture International
Verified
Journal Article
Closed access
PDF file
CMCristian Mejias
Cristian Mejias
CRCarlos Riquelme
Carlos Riquelme
CSCamila Sayes
Camila Sayes
JPJulián Plaza
Julián Plaza
FAFernando Rodrigo Silva Aciares
Fernando Rodrigo Silva Aciares


5 September 2025 in Membranes
Verified
Journal Article
Open access
PDF file
VCVictoria Cruz-Balladares
Victoria Cruz-Balladares
HVHernán Vera
Hernán Vera
CRCarlos Riquelme
Carlos Riquelme
FAFernando Rodrigo Silva Aciares
Fernando Rodrigo Silva Aciares
Background: Water scarcity is a pressing global challenge increasingly addressed by advanced desalination that converts seawater into potable water. Reverse osmosis and ultrafiltration dominate because they deliver permeate with very low impurities. Their principal limitation is membrane biofouling, which causes clogging, raises energy, operation, and maintenance costs, and shortens membrane life. Multiple approaches mitigate biofouling—most notably pretreatment trains and engineered surface coatings—but cleaning remains the most decisive remediation pathway. Current practice distinguishes physical, chemical, and biological cleaning. Biological cleaning has gained momentum by exploiting microorganisms that inherently counter biofilms. These strategies include targeted secretion of enzymes and antifouling metabolites, and the application of whole-cell culture supernatants containing the full suite of secreted components. In addition, predatory bacteria can infiltrate established biofilms and eradicate them by lysing prey, thereby accelerating the removal of adherent biomass. Progress across these bio-based approaches signals meaningful advances in fouling control and could substantially improve the efficiency, reliability, and sustainability of desalination facilities. Collectively, they underscore the transformative potential of biological antifouling agents in operational systems. Realizing that potential will require rigorous evaluation of technical performance, long-term stability, compatibility with polyamide membranes, regulatory acceptance, and environmental safety, ultimately alongside scalable production and cost-effective deployment in full-scale plants.

27 May 2020 in Biofouling
Verified
Journal Article
Closed access
HVHernán Vera-Villalobos
Hernán Vera-Villalobos
VPVilma Pérez
Vilma Pérez
FCFrancisco Contreras
Francisco Contreras
VAValezka Alcayaga
Valezka Alcayaga
VAVladimir Avalos
Vladimir Avalos
FAFernando Rodrigo Silva Aciares
Fernando Rodrigo Silva Aciares
Biofouling control in reverse osmosis membranes (ROMs) is challenging due to the high cost of treatments, and reduction in the life of ROMs. This study characterizes the biofouling in the ROMs from a desalination plant and reports its effective removal using the supernatant obtained fromAlteromonassp. strain Ni1-LEM. The characterization of the bacterial community revealed that the most abundant taxa in ROMs were the generaFulvivirgaandPseudoalteromonas, and unclassified species of the families Flavobacteriaceae and Sphingomonadaceae. This bacterial community significantly decreased upon treatment with the supernatant fromAlteromonassp. Ni1-LEM, resulting in the prevalence of the genusPseudoalteromonas. Furthermore, this bacterial supernatant significantly inhibited cell adhesion of seven benthic microalgae isolated from ROMs as well as promoting cell detachment of the existing microbial biofilms. The study showed that the extracellular supernatant modified the conformation of extracellular polymeric substances (EPS) in the biofouling of ROMs without any biocidal effects.

22 April 2023 in Membranes
Verified
Journal Article
Open access
PDF file
HVHernán Vera
Hernán Vera
CRCarlos Riquelme
Carlos Riquelme
FAFernando Rodrigo Silva Aciares
Fernando Rodrigo Silva Aciares
Biofouling refers to the undesirable growth of microorganisms on water-submerged surfaces. Microfouling, the initial state of biofouling, is characterized by aggregates of microbial cells enclosed in a matrix of extracellular polymeric substances (EPSs). In seawater desalination plants, filtration systems, such as reverse-osmosis membranes (ROMs), are affected by microfouling, which decreases their efficiency in obtaining permeate water. The existing chemical and physical treatments are expensive and ineffective; therefore, controlling microfouling on ROMs is a considerable challenge. Thus, new approaches are necessary to improve the current ROM cleaning treatments. This study demonstrates the application of Alteromonas sp. Ni1-LEM supernatant as a cleaning agent for ROMs in a desalination seawater plant in northern Chile (Aguas Antofagasta S.A.), which is responsible for supplying drinking water to the city of Antofagasta. ROMs treated with Altermonas sp. Ni1-LEM supernatant exhibited statistically significant results (p < 0.05) in terms of seawater permeability (Pi), permeability recovery (PR), and the conductivity of permeated water compared with control biofouling ROMs and those treated with the chemical cleaning protocol applied by the Aguas Antofagasta S.A. desalination plant.

2 July 2024 in Desalination
Verified
Journal Article
Closed access
HVHernán Vera
Hernán Vera
VCVictoria Cruz-Balladares
Victoria Cruz-Balladares
ÁGÁlvaro González-Gutiérrez
Álvaro González-Gutiérrez
VAVladimir Avalos
Vladimir Avalos
CRCarlos Riquelme
Carlos Riquelme
FAFernando Rodrigo Silva Aciares
Fernando Rodrigo Silva Aciares