Yanlin Sui

Dr. Yanlin Sui

Changchun Institute of Optics, Fine Mechanics and Physics, Changchun, Jilin, China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2019 in International Journal of Remote Sensing
Verified
Journal Article
Closed access
YSYanlin Sui
Yanlin Sui
BHBin He
Bin He
TFTianjiao Fu
Tianjiao Fu
In this paper, the energy characteristics of Gabor texture are used for cloud detection in high-resolution multispectral images. First, the satellite remote-sensing image is divided into superpixels using simple linear iterative clustering (SLIC), and then, the energy characteristics of Gabor texture and spectral characteristics are computed by extracting the texture features of the superpixels. The features of the cloud superpixels are used as the learning sample of the support vector machine (SVM) classifier, and a classification model is obtained by training the SVM classifier. Finally, a cloud-detection experiment is conducted for various sensor images with three visible bands and one near-infrared band. The experimental results showed that the proposed method provides an excellent average overall accuracy for thick and thin clouds in a complex background of forests, harbours, snow and mountains. The characteristic parameters of this paper are not limited by the image parameters; thus, they provide good results and universality for various types of sensors.

29 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YSYanlin Sui
Yanlin Sui
TYTao Yu
Tao Yu
LWLongqi Wang
Longqi Wang
Zhi WangZhi Wang
Zhi Wang
KXKe Xue
Ke Xue
YCYongkun Chen
Yongkun Chen
In space gravitational-wave-detection missions, inertial sensors are used as the core loads, and their acceleration noise needs to reach 3×10−15 ms−2/Hz at a frequency of 0.1 mHz, which corresponds to the capacitive sensing system; the capacitive sensing noise on the sensitive axis needs to reach 1 aF/Hz. Unlike traditional circuit noise evaluation, the noise in the mHz frequency band is dominated by the thermal noise and the 1/f noise of the device, which is a challenging technical goal. In this paper, a low-frequency, high-precision resonant capacitor bridge method based on a planar transformer is used. Compared with the traditional winding transformer, the developed planar transformer has the advantages of low temperature drift and low 1/f noise. For closed-loop measurements of capacitive sensing circuits and sensitive structures, the minimum capacitive resolution in the time domain is about 3 aF, which is far lower than the scientific measurement resolution requirement of 5.8 fF for gravitational wave detection. The capacitive sensing noise is converted to 1.095 aF/Hz in the frequency band of 10 mHz–1 Hz. Although there is a gap between the closed-loop measurement results and the final index, the measurement environment is an experimental condition without temperature control on the ground; additionally, in China, the measurement integrity and actual measurement results of the capacitive sensing function have reached a domestic leading level. This is the realization of China’s future space gravitational wave exploration.

15 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ZWZhenpeng Wang
Zhenpeng Wang
TYTao Yu
Tao Yu
YSYanlin Sui
Yanlin Sui
Zhi WangZhi Wang
Zhi Wang
In space gravitational wave detection missions, the laser heterodyne interference signal (LHI signal) has a high-dynamic characteristic due to the Doppler shift. Therefore, the three beat-notes frequencies of the LHI signal are changeable and unknown. This may further lead to the unlocking of the digital phase-locked loop (DPLL). Traditionally, fast Fourier transform (FFT) has been used as a method for frequency estimation. However, the estimation accuracy cannot meet the requirement of space missions because of the limited spectrum resolution. In order to improve the multi-frequency estimation accuracy, a method based on center of gravity (COG) is proposed. The method improves the estimation accuracy by using the amplitude of the peak points and the neighboring points of the discrete spectrum. For different windows that may be used for signal sampling, a general expression for multi-frequency correction of the windowed signal is derived. Meanwhile, a method based on error integration to reduce the acquisition error is proposed, which solves the problem of acquisition accuracy degradation caused by communication codes. The experimental results show that the multi-frequency acquisition method is able to accurately acquire the three beat-notes of the LHI signal and meet the requirement of space missions.