Anna Salvian

Dr. Anna Salvian

Analytical Chem., Physical Chem., and Chem. Eng., UAH, Alcalá de Henares, Spain
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2024 in npj Clean Water
Verified
Journal Article
Open access
PDF file
ASAnna Salvian
Anna Salvian
DFDaniel Farkas
Daniel Farkas
MRMarina Ramirez-Moreno
Marina Ramirez-Moreno
DTDaniela Torruella-Salas
Daniela Torruella-Salas
ABAntonio Berná
Antonio Berná
SGSiddharth Gadkari
Siddharth Gadkari
Efficient wastewater treatment monitoring is vital for addressing water scarcity. Microbial fuel cells (MFCs) have emerged as real-time biosensors for biochemical oxygen demand (BOD) in urban wastewater. Discrepancies in signal generation may arise due to changes in the composition and metabolism of mixed-culture electroactive biofilms stemming from different wastewater compositions. In this study, 3D-printed MFC-based biosensors were employed to assess the BOD of sterile complex artificial wastewater and untreated urban wastewater. Alterations in the microbial composition of the anode were evaluated using 16S rRNA sequencing and metagenomics analysis. Results show that MFC-based biosensors can be effectively recalibrated for diverse types of wastewater, maintaining consistent sensitivity (0.64 ± 0.10 mA L mg−1 m−2 with synthetic wastewater and 0.78 ± 0.13 mA L mg−1 m−2 with urban wastewater) and limit of detection (49 ± 8 mg L−1 for synthetic wastewater and 44 ± 7 mg L−1 for urban wastewater). Crucially, pre-sterilization, conductivity adjustments, and nitrogen purging of wastewater are not required before its introduction into the biosensor. However, the presence of native aerobic microorganisms in the wastewater might affect the current output. Metagenomics and taxonomic analyses revealed that the alterations in biofilm composition are predominantly in response to the varied chemical and microbiological compositions of different substrates. Despite variations in anodic biofilm composition, the MFC-based biosensor maintains a relative error comparable to the standard BOD test. This highlights the resilience and flexibility of the biosensor when directly used with a variety of wastewater types before full biofilm adjustment.

13 March 2023 in Microorganisms
Verified
Journal Article
Open access
PDF file
RNRosa Anna Nastro
Rosa Anna Nastro
ASAnna Salvian
Anna Salvian
KCKuppam Chandrasekhar
Kuppam Chandrasekhar
VPVincenzo Pasquale
Vincenzo Pasquale
APAndrea Pietrelli
Andrea Pietrelli
Claudio Avignone RossaClaudio Avignone Rossa
Claudio Avignone Rossa
The need for greener processes to satisfy the demand of platform chemicals together with the possibility of reusing CO2 from human activities has recently encouraged research on the set-up, optimization, and development of bioelectrochemical systems (BESs) for the electrosynthesis of organic compounds from inorganic carbon (CO2, HCO3−). In the present study, we tested the ability of Clostridium saccharoperbutylacetonicum N1-4 (DSMZ 14923) to produce acetate and D-3-hydroxybutyrate from inorganic carbon present in a CO2:N2 gas mix. At the same time, we tested the ability of a Shewanella oneidensis MR1 and Pseudomonas aeruginosa PA1430/CO1 consortium to provide reducing power to sustain carbon assimilation at the cathode. We tested the performance of three different systems with the same layouts, inocula, and media, but with the application of 1.5 V external voltage, of a 1000 Ω external load, and without any connection between the electrodes or external devices (open circuit voltage, OCV). We compared both CO2 assimilation rate and production of metabolites (formate, acetate 3-D-hydroxybutyrate) in our BESs with the values obtained in non-electrogenic control cultures and estimated the energy used by our BESs to assimilate 1 mol of CO2. Our results showed that C. saccharoperbutylacetonicum NT-1 achieved the maximum CO2 assimilation (95.5%) when the microbial fuel cells (MFCs) were connected to the 1000 Ω external resistor, with the Shewanella/Pseudomonas consortium as the only source of electrons. Furthermore, we detected a shift in the metabolism of C. saccharoperbutylacetonicum NT-1 because of its prolonged activity in BESs. Our results open new perspectives for the utilization of BESs in carbon capture and electrosynthesis of platform chemicals.

20 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
ASAnna Salvian
Anna Salvian
DFDaniel Farkas
Daniel Farkas
MRMarina Ramírez-Moreno
Marina Ramírez-Moreno
Claudio Avignone RossaClaudio Avignone Rossa
Claudio Avignone Rossa
JVJohn R. Varcoe
John R. Varcoe
SGSiddharth Gadkari
Siddharth Gadkari
The increasing global water pollution leads to the need for urgent development of rapid and accurate water quality monitoring methods. Microbial fuel cells (MFCs) have emerged as real-time biosensors for biochemical oxygen demand (BOD), but they grapple with several challenges, including issues related to reproducibility, operational stability, and cost-effectiveness. These challenges are substantially shaped by the selection of an appropriate air-breathing cathode. Previous studies indicated a critical influence of the cathode on both the enduring electrochemical performance of MFCs and the taxonomic diversity at the electroactive anode. However, the effect of different gas diffusion electrodes (GDE) on 3D-printed single-chamber MFCs for BOD biosensing application and its effect on the bioelectroactive anode was not investigated before. Our study focuses on comparing GDE cathode materials to enhance MFC performance for precise and rapid BOD analysis in wastewater. We examined for over 120 days two Pt-coated air-breathing cathodes with distinct carbonaceous gas diffusion layers (GDLs) and catalyst layers (CLs): cost-effective carbon paper (CP) with hand-coated CL and more expensive woven carbon cloth (CC) with CL pre-applied by the supplier. The results show significant differences in electrochemical characteristics and anodic biofilm composition between MFCs with CP and CC GDE cathodes. CP-MFCs exhibited lower sensitivity (16.6 C L mg−1 m−2) and a narrower dynamic range (25 to 600 mg L−1), attributed to biofouling-related degradation of the GDE. In contrast, CC-MFCs demonstrated superior performance with higher sensitivity (37.6 C L mg−1 m−2) and a broader dynamic range (25 to 800 mg L−1). In conclusion, our study underscores the pivotal role of cathode selection in 3D-printed MFC biosensors, influencing anodic biofilm enrichment time and overall BOD assessment performance. We recommend the use of cost-effective CP GDL with hand-coated CL for short-term MFC biosensor applications, while advocating for CC GDL supplied with CL as the preferred choice for long-term sensing implementations with enduring reliability.

3 February 2025 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
ASAnna Salvian
Anna Salvian
SSShailza Saini
Shailza Saini
MRMarina Ramirez-Moreno
Marina Ramirez-Moreno
CAClaudio Avignone-Rossa
Claudio Avignone-Rossa
JVJohn R. Varcoe
John R. Varcoe
SGSiddharth Gadkari
Siddharth Gadkari

13 June 2024 in Water
Verified
Journal Article
Open access
PDF file
Razieh RafieeniaRazieh Rafieenia
Razieh Rafieenia
MMMohamed Mahmoud
Mohamed Mahmoud
MAMahmoud Saad Abdel-Wahed
Mahmoud Saad Abdel-Wahed
TGTarek A. Gad-Allah
Tarek A. Gad-Allah
ASAnna Salvian
Anna Salvian
Claudio Avignone RossaClaudio Avignone Rossa
Claudio Avignone Rossa
We developed a solar-driven photo-bioelectrochemical cell (s-PBEC) employing a novel anode photocatalyst material (Co3(PO4)2/Mg(OH)2) intimately coupled with electrochemically active bacteria for synergic electricity generation from wastewater. An s-PBEC was inoculated with a natural microbial community and fed with synthetic wastewater to analyze the performance of the system for electricity generation. Linear sweep voltammetry indicated an increase in power output upon light illumination of the s-PBEC after 1 h, rising from 66.0 to 91.5 mW/m2. The current density in the illuminated s-PBEC exhibited a rapid increase, reaching 0.32 A/m2 within 1 h, which was significantly higher than the current density in dark conditions (0.15 A/m2). Shotgun metagenomic analysis revealed a significant shift in the microbial community composition with a more diverse anodic biofilm upon illumination compared to the microbial communities in dark conditions. Three unclassified genera correlated with the enhanced current generation in illuminated s-PBEC, including Neisseriales (16.31%), Betaproteobacteria (7.37%), and Alphaproteobacteria (5.77%). This study opens avenues for further exploration and optimization of the solar-driven photo-bioelectrochemical cells, paving the way for integrative approaches for sustainable energy generation and wastewater treatment.

22 October 2025 in Advanced Sensor Research
Verified
Journal Article
Open access
ASAnna Salvian
Anna Salvian
JHJunbin Huang
Junbin Huang
DFDaniel Farkas
Daniel Farkas
JVJohn R. Varcoe
John R. Varcoe
Claudio Avignone RossaClaudio Avignone Rossa
Claudio Avignone Rossa
SGSiddharth Gadkari
Siddharth Gadkari
In this study, a novel 3D‐printed glassy carbon gyroid anode is constructed using stereolithography, aiming to improve microbial fuel cell (MFC)‐based biosensor performance through a simple method that optimizes both the macroporous structure and hydrophilicity of the anode. Comparative studies are conducted between MFC‐based biosensors with traditional carbon felt (CF‐MFCs) and those with the 3D‐printed resin anode (RE‐MFCs). In batch mode, RE‐MFCs show a linear dynamic range from 26 to 405 mg L −1 , +126% higher than CF‐MFCs (26–194 mg L −1 ). However, a reduction in sensitivity is observed (0.40 ± 0.08 mA m −2 mg −1 L −1 for RE‐MFCs and 1.02 ± 0.08 mA m −2 mg −1 L −1 ). In continuous flow mode at a flow rate of 0.1 mL min −1 (HRT = 5 h), the RE‐MFCs demonstrated up to 35% higher sensitivity (1.45 mA m −2 mg −1 L −1 ) than the CF‐MFCs (0.94 mA m −2 mg −1 L −1 ) due to increased mass transport and better biofilm activity. Despite using the same inoculum, different microbial electroactive biofilms formed on the CF and RE anodes. Biofilm communities are influenced more by the operation mode than by the anode material choice. This study introduces an innovative anode material that can be tailored to increase dynamic range or sensitivity based on MFC operation mode and calibration strategy.