Determination method for maximum wetting plane position, which is conventional in Russia, is considered. The method is based on the theory of vapor-state and liquid-state moisture combined transfer. Expressions for moisture potential F and maximum wetting complex applied for maximum wetting calculation in the enclosing structure are quoted. Graphic modification of the calculation method for maximum wetting plane position is proposed. Three analytic techniques for the enclosing structure are formulated. These techniques allow graphical determination of maximum wetting plane within the enclosing structure layer, at the joint between adjacent layers, and outside the structure. This method is applied to the enclosing structure, which is represented a facade heat-insulating composite system with exterior plaster layer, aerated concrete masonry and mineral insulation. It is found out that maximum wetting plane of this structure is located inside insulation layer. The plane is determined by the first analytical technique. It is reported that calculation results using graphical method correspond to results obtained using existing analytical method.
The paper proposes mathematical model for unsteady-state moisture behaviour calculation of single-layer enclosing structures by means of moisture potential and discrete-continuous method. A formula for moisture potential value calculation for single-layer enclosing structure in any enclosing structure section, at any moment of time, under continuous control for temperature distribution, has been derived. Moisture transfer between the enclosing structure and ambient air is taken into account by means of third-kind boundary conditions. Temperature distribution is taken as constant during a month. The proposed method allows for moisture potential determination according to the proposed formula for every month. Calculation results obtained by the proposed method, well-known unsteady-state method and engineering method developed by V.G. Gagarin and V.V.Kozlov have been compared for single-layer enclosing structure made of aerated concrete. It was shown that average value calculation results disagreement does not exceed 7% for the proposed method and unsteady-state method. However, the proposed approach allows for moisture distribution determination using analytical expression, which is convenient for use in engineering practice.
10 August 2018 in IOP Conference Series: Earth and Environmental Science
The paper studies unsteady-state moisture behavior of multilayer enclosing structure using discrete-continuous method. Modification of Gagarin's differential moisture transfer equation is proposed. The proposed moisture transfer equation within one layer of a multilayer enclosing structure is a second-order differential parabolic equation with constant coefficients. Third-kind boundary conditions of moisture exchange are set for enclosing structure boundaries. Fourth-kind boundary conditions represented by moisture potential flows equality are set at the joint of two different materials. An analytical expression for moisture potential calculation in any enclosing structure section, at any time, under continuous control for temperature distribution, has been derived using discrete-continuous method. Calculations for multilayer enclosing structure consisting of clay brick base and lime brick lining have been made. The obtained results have been compared to calculation results obtained by well-known Gagarin's unsteady-state method and Kozlov's engineering method. It has been shown that the discrete-continuous method allows calculating unsteady-state moisture behavior of multilayer enclosing structures by analytical expression, and obtaining moisture distribution similar to Gagarin's unsteady-state method, thus it can be used by design engineers in practice.
31 December 2018 in IOP Conference Series: Materials Science and Engineering
The paper proposes a device for vapor permeability coefficient determination in case of vertical sample position. The device is a L-type section capacity with a window in upper part of long side of the capacity. A test sample of construction material is positioned vertically and sealed in the window. The capacity has built-in relative air humidity sensors distributed along capacity height. These sensors allow measuring height-average relative air humidity. Experimental vapor permeability coefficient values, obtained by means of the proposed device and by means of well-known wet cup method, have been compared. Rock wool has been used as a test material. As a result, wet cup method has been confirmed for vapor permeability coefficient determination for vertical enclosing structures.
The paper describes principal development directions of mathematical models of enclosing structure moisture regime. Benefits of mathematical models based on moisture potential theory are demonstrated. Moisture regime calculation by means of moisture potential, taking liquid and vapor moisture transfer into consideration, and using discrete-continual approach is proposed. New formulas for single-layer and multi-layer enclosing structures allowing for numerical analytic determination of moisture potential value in any enclosing structure section, at any moment of time, under continuous control of temperature distribution, have been derived. Moisture distribution has been studied for a number of enclosing structures using different methods of moisture potential theory: unsteady-state method, quasi-stationary method, the proposed discrete-continual method. Moisture regime has been determined for single-layer enclosing structure with ceramic brick basement and lime brick cladding in Moscow. It is shown that the greatest moisture value is achieved in enclosing structure calculation by means of steady-state method. Unsteady-state method gives more accurate moisture distribution. The proposed discrete-continual method gives quantitative and qualitative result of moisture distribution similar to results obtained by unsteady-state method. The benefit of discrete-continual method is a distribution obtained analytically, which allows to use solution results without numerical method application.