João Gabriel Luppi Foster

Mr. João Gabriel Luppi Foster

IESTI, Federal University of Itajubá, Itajubá, Brazil
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
Sílvia Costa FerreiraSílvia Costa Ferreira
Sílvia Costa Ferreira
JFJoão Gabriel Luppi Foster
João Gabriel Luppi Foster
RGRobson Bauwelz Gonzatti
Robson Bauwelz Gonzatti
RPRondineli Rodrigues Pereira
Rondineli Rodrigues Pereira
GPGuilherme Gonçalves Pinheiro
Guilherme Gonçalves Pinheiro
BGBruno P. Braga Guimarães
Bruno P. Braga Guimarães
This paper presents a novel strategy for online parameter estimation in a hybrid active power filter (HAPF). This HAPF makes use of existing capacitor banks which it combines with an active power filter (APF) in order to dynamically compensate reactive power. The equipment is controlled with finite control set model predictive control (FCS-MPC) due to its already well-known fast dynamic response. The HAPF model is similar to a grid-connected LCL-filtered converter, so the direct control of the HAPF current can cause resonances and instabilities. To solve this, indirect control, using the capacitor voltage and the inverter-side current, is applied in the cost function, which creates high dependency between the system parameters and the equipment capability to compensate the load reactive power. This dependency is evaluated by simulations, in which the capacitor bank reactance is shown to be the most sensitive parameter, and, thus, responsible for inaccuracies in the FCS-MPC references. In order to minimize this problem without increasing the complexity of the FCS-MPC algorithm, an estimation technique, based on adaptive notch filters, is proposed. The proposed algorithm is tested in a laboratory prototype to demonstrate its ability to follow variations in the HAPF capacitor reactance, effectively correcting the reactive power reference and providing dynamic reactive power compensation. During the tests, the proposed algorithm was capable of keeping the supplied reactive power within a 1% error, even in a situation with 33% variation in the HAPF capacitor reactance.

26 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
BGBruno Pinto Braga Guimarães
Bruno Pinto Braga Guimarães
Ronny Francis Ribeiro JuniorRonny Francis Ribeiro Junior
Ronny Francis Ribeiro Junior
MAMarcos Vinicius Andrade
Marcos Vinicius Andrade
IAIsac Areias
Isac Areias
JFJoão Gabriel Luppi Foster
João Gabriel Luppi Foster
YEYasmina El-Heri
Yasmina El-Heri
The integration of renewable energy sources is crucial for achieving sustainability and environmental preservation. However, their intermittent nature poses challenges to electrical system stability, requiring robust integration strategies. Microgrids emerge as a flexible solution, but their successful deployment requires meticulous planning and intelligent operation to overcome these challenges. This paper presents the development of a reduced-scale laboratory dedicated to researching both hardware and software solutions for intelligent microgrid management. The laboratory was designed to incorporate key components that are becoming increasingly important in the present microgrid context, including renewable energy generation, storage systems, electrolyzers for hydrogen production, and combined heat and power sources. While some equipment consists of commercial models, the battery bank, converter, and supervisory systems were custom-designed to meet the specific requirements of the laboratory. The laboratory has proven itself as a robust tool for conducting studies on microgrids, effectively incorporating essential components, addressing pertinent system issues, and allowing for several tests on converting control algorithms.

13 February 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JFJoão Gabriel Luppi Foster
João Gabriel Luppi Foster
Sílvia Costa FerreiraSílvia Costa Ferreira
Sílvia Costa Ferreira
RGRobson Bauwelz Gonzatti
Robson Bauwelz Gonzatti
RPRondineli Rodrigues Pereira
Rondineli Rodrigues Pereira
YSYago A. Santos
Yago A. Santos
This article provides a novel control strategy for a single-phase multilevel hybrid active power filter (HAPF) with LCL-filter coupling applied for reactive power compensation and harmonics mitigation with finite control set mode predictive control (FCS-MPC). The proposed strategy was designed aiming to reduce the control complexity and computational burden, which is important when considering the application of FCS-MPC to multilevel converters. The proposed method avoids the application of cascaded controllers in the current control loop, considering only the system model for the calculation of the references. Tests performed in a 7.5 kVA laboratory prototype demonstrate the technique capability to maintain unity power factor at the source, keep the source current within THD standards and reduce the computational time in almost 30% when compared to the application of cascaded controllers in the current reference calculation.

15 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
GPGuilherme Gonçalves Pinheiro
Guilherme Gonçalves Pinheiro
RGRobson Bauwelz Gonzatti
Robson Bauwelz Gonzatti
CSCarlos Henrique da Silva
Carlos Henrique da Silva
RPRondineli Rodrigues Pereira
Rondineli Rodrigues Pereira
BGBruno P. Braga Guimarães
Bruno P. Braga Guimarães
JSJoselino Santana-Filho
Joselino Santana-Filho
The application of power electronics equipment in medium voltage (MV) distribution grids can provide new management solutions for power flow control, load balancing and voltage problems. A series MV VSC-based power flow controller has recently been presented to interconnect two radial distribution feeders performing active and reactive power transfers to improve the flexibility and utilization of these circuits in a controlled and secure way. Although not previously explored, this power flow controller can integrate the functionality of a series power filter, accomplishing independent control of the fundamental power flow while isolating the harmonic content between the two interconnected feeders. This prevents harmonic pollution from one feeder from propagating to the other, improving the voltage quality. To implement the harmonic isolation, several control strategies can be used. Therefore, this paper provides a comparative analysis between two of the main harmonic control techniques found in the literature: the Synchronous Reference Frame (SRF) controller and the Proportional Resonant (PR) controller. Assessments are conducted both through simulations and experimental results in a meshed network at 13.8 kV with different types of non-linear loads. In the simulation cases, both algorithms showed similar results; however, in the experimental cases, the PR-based solution exhibited better performance in isolating the harmonics from one feeder to the other.