The purpose of this study is to identify the differences in porosity and permeability coefficients when the mixing ratio of aggregates is different and to present the mixing ratio satisfying the strength requirement of compressive specified in a specification of Korea. Three mix ratios were suggested by considering various aggregate sizes and three cylinders were made for each ratio. The porosities of those cylinders were evaluated through the compression and water permeability test, measuring the weight of specimens in underwater and analysis of the pictured Computed Tomography (CT) image. Experiments have shown that it is best to mix 50% for 5–10 mm aggregates, 45% for 2–5 mm aggregates, and 5% for sand in terms of strength and permeability. In addition, as the proportion of fine aggregates increased, the porosity and permeability decreased. Moreover, the effectiveness of maintenance method was also examined in this study.
To date, a method of attaching a FRP (fiber-reinforced polymer) to concrete members with epoxy has been widely applied to increase the strength of the member. However, there are cases in which the adhesion of the epoxy deteriorates over time and the reinforcing effect of the FRP is gradually lost. Therefore, monitoring whether or not the reinforcing effect is properly maintained is needed in order to prevent a decrease in the structural performance of the member improved by FRP reinforcement. In this regard, this study examines FRP with OF (optical fiber) sensors to monitor the reinforcing effect of FRP in concrete structural members. In particular, this paper seeks to determine an appropriate adhesion length when FBG (fiber Bragg grating) based OF sensors are externally bonded to FRP strips with epoxy resin. To this end, a tensile test was carried out to evaluate the sensing performance according to the adhesion length. In addition, an analytical approach was performed and the result were compared with test result. The results of the experimental and analytical studies showed that the strain generated in the FRP is sufficiently transferred to the OF if the total adhesion length of it is 40 mm or more in consideration of the error in the epoxy thickness.
Two types of multi-walled carbon nanotubes (MWCNTs), powder and liquid, were added to cementitious composites to build self-sensing concrete. To properly evaluate and quantify the effect of MWCNTs on electrical resistance, various tests, including isothermal conduction calorimetry, were carried out. One of primary issues of self-monitoring concrete is dispersion, so ultrasonication was used to properly mix the CNTs in the dispersion solution, and silica fume was employed to make the specimens. Scanning electron microscopy (SEM), Raman spectroscopy, and porosity analyses were performed to investigate the physical properties of the composites and to confirm uniform dispersion. The distance of the electrical resistance was also measured, and the dosages and types of MWCNTs were analyzed.
This study analyzed the influence of carbon nanotubes (CNTs) on the carbonation conductive cementitious composites. Two powder types of CNT, multi-walled and single-wall CNTs, were employed to give the cement mortar the conductivity, and four tests including the accelerated carbonation, compressive and flexural strength, electrical resistance, and porosity tests were carried out. To intentionally accelerate the carbonation, the prismatic specimens of conductive cement composites were fabricated and stored in the controlled environmental chamber at a constant temperature of 20 ± 2 °C, constant relative humidity of 60 ± 5%, and carbon dioxide (CO2) concentration of 5% for 12 weeks. It was observed that carbonation resulted in only chemical damage so that there was no change in the electrical resistance value of conductive cementitious mortar that had undergone a carbonation attack.
This study analyzed changes in the durability characteristics of cement mortar incorporating carbon nanotube (CNT) and the electrical properties subjected to deterioration induced by sulfate attack. Powder types of multi-walled or single-walled CNTs were used and added to the composites with 1.0% and 2.0% mass fraction, and the specimens were immersed in 5% and 10% sulfuric acid solutions to investigate the durability of CNT cementitious composites. Although mechanical performance decreased due to relatively large pores (370–80 μm) caused by CNTs, specimens incorporating CNTs exhibited enhanced resistance to sulfuric acid as CNTs, which offered strong resistance to acid corrosion, and prevented contact between the cement hydrate and the sulfuric acid solution. Therefore, it is expected that self-sensing performance was exhibited because there were no significant differences in the electrical properties of cement mortar subjected to the deterioration by sulfate attack.
This study analyzed the mechanical and electrical characteristics of repair self-sensing composites. In order to ensure homogeneous dispersion of carbon nanotubes (CNTs) in the repair mortar, porous powder was impregnated with the liquid MWCNT, dried, and then pulverized. This CNT powder was named S-CNT, and a repair self-sensing cement composite was fabricated using it with different dosages, by weight, of 3, 6, and 9%. Mechanical and electrical performances of the developed materials were investigated through flexural, compressive, and bonding strengths, dry shrinkage, porosity, and fractional change in resistance (FCR) tests. There was little difference in terms of strength, between the three different composites made with the different dosages of S-CNT. The strength of the composite with 9% of S-CNT was even higher than that of the plain specimen. As a result of measuring drying shrinkage, conducted to evaluate the effect of improving dispersion, the length change rate decreased as the amount of S-CNT increased. As a result of the porosity results of the specimens incorporating the same mass of CNT as S-CNT, it was confirmed that the dispersibility was clearly improved. In addition, as an electrical characteristic, when the S-CNT mixed specimen was repeatedly loaded with a bending load, FCR appeared, confirming the self-sensing performance.