Weixiang Huang

Weixiang Huang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2023 in IEEE Access
Verified
Journal Article
Open access
QCQianyi Chen
Qianyi Chen
SCShaonan Chen
Shaonan Chen
WHWeixiang Huang
Weixiang Huang
WZWei Zhang
Wei Zhang
KLKewen Li
Kewen Li
Realizing online monitoring of the hot spot temperature of grid mounted transformer windings is a challenge for the power industry. The heat exchange process between the internal heat source area and the external field area of the transformer is the direct cause of the temperature increase of the transformer shell. In this paper, based on the numerical coupling calculation of temperature - fluid field of 10kV oil immersed solid coiled iron core transformer, the typical heat flow streamline is extracted, and the measurable temperature characteristic points strongly correlated to the winding hot spot temperature are selected in the heat dissipation area of the shell, and the inversion model of the transformer winding hot spot temperature is established. This article verifies the effectiveness of the simulation results and the accuracy of the inversion model through the multi condition temperature rise test of transformer. The maximum error between the calculated steady-state temperature rise of each temperature measurement point in the simulation model and the test value is no more than 3°C, the simulation calculation results are in good agreement with the test results, and the average absolute error of the inversion model winding hot spot temperature inversion is 2.67 %, the maximum temperature difference is less than 3°C. This research provides an effective method for online monitoring of the hot spot temperature of the winding of a 10kV oil-immersed three-dimensional coil iron core transformer, and provides a reference for the state detection of grid mounted transformers.

1 February 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
WHWeixiang Huang
Weixiang Huang
XYXiaoyong Yu
Xiaoyong Yu
LWLifang Wu
Lifang Wu
This paper states the test method and data application of a kind of physical model of power distribution network. After the establishment of distribution automation physical simulation laboratory, the equipment in the platform is effectively controlled and reasonable test procedures are designed. The detailed solution is to record the test process during the physical simulation test.In the design of this test method, the main difficulty is that the data of each equipment at each stage in the system shall be recorded completely during the whole process for physical reduction of transient fault, and to design the interface with the power system simulation software; otherwise, the meaning of the test will be discounted heavily. The on-site operating environment of the distribution network can be restored furthest, all details in the test process can be presented to the testers clearly and intuitively, and the test data can be expanded and applied to provide strong support for technical research and analysis of distribution automation in this way.


14 September 2026 in Atmosphere
Verified
Journal Article
Open access
PDF file
WHWeixiang Huang
Weixiang Huang
WZWei Zhang
Wei Zhang
XCXi Chen
Xi Chen
WHWeijun Hu
Weijun Hu
BFBo Feng
Bo Feng
SLShan Li
Shan Li
Cloud-to-ground (CG) stroke density is key for lightning hazard risk assessment, but conventional grid-cell methods face an inherent trade-off between spatial resolution and statistical confidence. To address this issue, this study takes Fangchenggang City, Guangxi, as the study area and proposes an extreme gradient boosting (XGBoost) regression model integrating high-resolution terrain features to estimate CG stroke density at the hundred-meter scale. The results show that the model produces a 0.001° × 0.001° density distribution that reproduces the spatial pattern of lightning activity. Within the ±30% error interval, the average confidence level of the model output is approximately 44.75%, while that of the grid-cell method is only 0.0163%. The two-dimensional information entropy reaches 10.70 bits, approximately 33.9% higher than that of the grid-cell method. SHAP analysis indicates that the XGBoost model successfully performed smooth interpolation on the raw data to obtain a high-resolution density map showing the effects of topographical factors. Furthermore, a case study of a lightning-induced trip-out event on a 220 kV transmission line illustrates the method’s potential applicability. Compared with kilometer-scale density data, the high-resolution data yield an identified faulty tower that is more consistent with the actual accident location. In summary, we have proposed an effective downscaling method for Cloud-to-Ground stroke density. It is worth noting, however, that independent validation remains limited and that the confidence calculation does not incorporate model uncertainty.

20 November 2026 in Energies
Verified
Journal Article
Open access
PDF file
WHWeixiang Huang
Weixiang Huang
XXXiaofei Xia
Xiaofei Xia
YYYixiong Yang
Yixiong Yang
CYChenying Yi
Chenying Yi
XCXi Chen
Xi Chen
HZHuang Zhidu
Huang Zhidu
A single lightning strike on a double-circuit transmission line with shared towers may affect both circuits, while lightning risk varies among towers along the line. This study examines a 110 kV line in Guangxi, China, using lightning monitoring and operational records. Multi-wave-impedance models of representative tower types were developed in ATP-EMTP, and lightning withstand levels were determined using an insulator voltage–time characteristic criterion implemented in MODELS. An electrogeometric model was then used to estimate tower-level shielding-failure and backflashover trip-out rates, classify lightning risk, and propose a line surge arrester configuration. Thirty-three towers were identified for priority protection. In a model-based preliminary assessment, the estimated lightning-induced trip-out rate decreased from 9.747 to 2.579 trips per 100 km per year, a reduction of 73.54%. This case study provides a reference for differentiated lightning protection of similar lines.