The heating of oil and oil products is widely used to reduce energy losses during transportation. An approach is developed to determine the effective length of the heat exchanger and the temperature of the cold coolant (oil) at its outlet in the case of a strong dependence of oil viscosity on temperature. Oil from the Uzen field (Kazakhstan) is considered as a heated coolant, and water is considered as a heating component. The method of the log–mean temperature difference, modified for the case of variable viscosity, and the methods of computational fluid dynamics (CFD) are used for calculations. The results of the numerical calculations are compared with the data obtained on the basis of a theoretical approach at a constant viscosity. When using a theoretical approach with a constant or variable viscosity, the heat transfer coefficients to cold and hot coolants are found using criterion dependencies. The Reynolds-averaged Navier–Stokes (RANS) and a turbulence model that takes into account the laminar–turbulent transition are applied. In the case of variable oil viscosity, a transition from the laminar flow regime to the turbulent one is manifested, which has a significant effect on the effective length of the heat exchanger. The obtained results of the CFD calculations are of interest for the design of heat exchangers of a new type, for example, helicoid ones.
1 January 2017 in Vestnik of Saint Petersburg University. Mathematics. Mechanics. Astronomy
Heating of oil and oil products is widely used to reduce energy losses during transportation. The flow in the annular space of the heat exchanger is complex and depends on many factors. The use of thin tubes in helicoid-type heat exchangers makes it necessary to take into account the transition of the flow regime from laminar to turbulent. The semi-empirical turbulence models traditionally used in numerical calculations do not take into account the laminar-turbulent transition. An approach is developed to determine the effective length of the heat exchanger and the temperature of the cold coolant at its outlet in the case of a strong dependence of oil viscosity on temperature, taking into account the possibility of a laminar-turbulent transition. Oil is considered as a heated coolant, and water is considered as a heating component. The novelty of the developed approach lies in the application of the turbulence model, which takes into account the laminar-turbulent transition, to the calculation of helicoid-type heat exchangers. For numerical simulation, the Reynolds-averaged Navier–Stokes equations are used which are closed using γ–Reθt turbulence model that takes into account the laminar-turbulent transition. The results of numerical calculations are compared with the data obtained on the basis of the log-mean temperature difference method at constant and variable viscosity. In the case of variable oil viscosity, a transition from the laminar flow regime to the turbulent one is manifested which has a significant effect on the effective length of the heat exchanger. The results of numerical calculations can be useful in designing helicoid-type heat exchangers.
We consider a laminar, stratified flow for a two-phase medium in inclined pipes of variable cross-section. Unsteady flows in pipes of variable cross-section, as a rule, are carried out on the basis of quasi-stationary equations obtained by averaging the Navier-Stokes equations over the entire cross section of the pipe. Based on the results of numerical simulation of a two-phase flow in an inclined pipe, mean cross-sectional velocities of phases and average frictional stresses for each of the liquids in interaction with the pipe walls and with each other are determined.
31 March 2026 in Eurasian Physical Technical Journal
Increased energy efficiency in the extraction and transportation of highly viscous oil is achieved by reducing its viscosity through heating. Numerical modeling is a powerful tool for developing and analyzing methods to improve heat transfer efficiency and optimize the design of heat exchange devices in the oil and gas industry. To solve this problem, the study uses Reynolds-averaged Navier-Stokes equations supplemented with turbulence models (k–ε, k–ω SST, and Transition SST) capable of accounting for the transition from laminar flow to turbulent flow with variable viscosity. The results of calculations of smooth and spiral pipes are compared, as well as an assessment of the reliability and performance of turbulence models used to simulate the operation of heat exchangers with direct and reverse heat flow. The dependences of the numbers Nu and Re of the oil flow in a washed by water pipe for all three turbulence models are shown in comparison with the corresponding experimental result, indicating the qualitative agreement of the numerical calculation results with the experiment. The results of the comparative analysis showed that the kw SST model most effectively describes the flow movement in the inter-tube space. The Computational Fluid Dynamics calculation data obtained is of practical importance for the design and optimization of heat exchanger structures.
30 September 2025 in Bulletin of the Karaganda University "Physics Series"
In this paper, the heat exchange processes between a cold (oil) and a highly heated (water) heat carrier in a“tube-in-tube” type heat exchanger with a parallel flow scheme are studied using semi-empirical turbulencemodels: k-ω SST, k-ε, and Transition SST. The analysis of the obtained results showed that the k-ω SSTturbulence model was more preferable for the calculation of a heat exchanger with a sufficiently small tubediameter, because of the effect of the boundary layer in the tube. This turbulence model more pronouncedlyreproduces the laminar-turbulent transition, which is carried out in these processes, where the viscosity of oilstrongly depends on temperature. Finite difference and finite volume methods were chosen for numericalmodelling and calculation of heat exchange processes. The calculations were carried out on the basis ofComputational Fluid Dynamics, using the Ansys Fluent. The RANS equations closed by means of thegamma-Retheta turbulence model, which takes into account the laminar-turbulent transition and the k-ω SSTmodel equations, were used for numerical modelling of coolant hydrodynamics. Based on the proposedturbulence model, the distributions of hydrodynamic and thermal parameters and similarity criteria (Re, Pr,Nu) of the process along the length of the tube are obtained.