Probing The Structure And Dynamics Of Nucleosomes Using Atomic Force Microscopy Imaging. JoVE publishes peer-reviewed scientific video protocols to accelerate biological, medical, chemical and physical research. Watch our scientific video articles. JoVE is the world-leading producer and provider of science videos with the mission to improve scientific research, scientific journals, and education. Millions of scientists, educators and students at thousands of universities, colleges, hospitals and biopharmaceutical companies worldwide use JoVE for their research, teaching and learning.
Atomic Force Microscopy (AFM) is widely used for topographic imaging of DNA and protein-DNA complexes in ambient conditions with nanometer resolution. In AFM studies of protein-DNA complexes, identifying the protein’s location on the DNA substrate is one of the major goals. Such studies require distinguishing between the DNA ends, which can be accomplished by end-specific labeling of the DNA substrate. We selected as labels three-way DNA junctions (3WJ) assembled from synthetic DNA oligonucleotides with two arms of 39–40 bp each. The third arm has a three-nucleotide overhang, GCT, which is paired with the sticky end of the DNA substrate generated by the SapI enzyme. Ligation of the 3WJ results in the formation of a Y-type structure at the end of the linear DNA mole cule, which is routinely identified in the AFM images. The yield of labeling is 69%. The relative orientation of arms in the Y-end varies, such dynamics were directly visualized with time-lapse AFM studies using high-speed AFM (HS-AFM). This labeling approach was applied to the characterization of the nucleosome arrays assembled on different DNA templates. HS-AFM experiments revealed a high dynamic of nucleosomes resulting in a spontaneous unraveling followed by disassembly of nucleosomes.
In the absence of a functioning centromere, chromosome segregation becomes aberrant, leading to an increased rate of aneuploidy. The highly specific recognition of centromeres by kinetochores suggests that specific structural characteristics define this region, however, the structural details and mechanism underlying this recognition remains a matter of intense investigation. To address this, High speed atomic force microscopy was used for direct visualization of the spontaneous dynamics of CENP-A nucleosomes at the sub-second time scale. We report that CENP-A nucleosomes change conformation spontaneously and reversibly, utilizing two major pathways: unwrapping, and looping of the DNA; enabling core transfer between neighboring DNA substrates. Along with these nucleosome dynamics we observed that CENP-A stabilizes the histone core against dissociating to histone subunits, unique from H3 cores which are only capable of such plasticity in the presence of remodeling factors. These findings have implications for the dynamics and integrity of nucleosomes at the centromere.
In bacteria, the restart of stalled DNA replication forks requires the PriA DNA helicase. PriA recognizes and remodels abandoned DNA replication forks performing the DNA unwinding in 3’ to 5’-direction and facilitates loading of the DnaB helicase onto the DNA to restart replication. The single stranded DNA binding protein (SSB) is typically present at the abandoned forks, but there is gap in the knowledge on the interaction between SSB and PriA protein. Here, we used atomic force microscopy (AFM) to visualize the interaction of PriA with DNA substrates in the absence or presence of SSB. Results show that in the absence of SSB, PriA binds preferentially to a fork substrate with a gap in the leading strand. Preferential binding occurs only on forked DNA structures as 5’- and 3’-tailed duplexes were bound equally well. Furthermore, in the absence of SSB, PriA bound exclusively to the fork regions of substrates. In contrast, fork bound SSB loads PriA onto the duplex DNA arms of forks. When the fork has a gap in the leading strand, PriA localizes to both the parental and lagging strand arms. When the gap is present in the lagging strand, PriA is loaded preferentially onto the leading strand arm of the fork. Remodeling of PriA requires a functional C-terminal domain of SSB.
Mechanical force is an important component of life implicit in molecular, cellular, and organismal function. A wide variety of force-probing techniques, including atomic force microscopy (AFM) and optical and magnetic tweezers have been developed. This chapter presents the principles underlying magnetic tweezers for probing single molecules, along with advantages and limitations of the method. The major feature of magnetic tweezers is that the force measurements are done directly without any calibration of the sensor. This property is the inherent feature of the instrument in which force is measured from analysis of the Brownian motion of the tethered bead. The instrument-dependent resolution limits are determined by the charge-coupled device (CCD) and bead-illumination characteristics. The systematic error limitation can come from the sample drift or the finite integration time of the CCD camera, and the effects of these errors arise when the applied force increases.