Plasticized poly(vinyl chloride) (PVC) gels belong to a class of electroactive polymers (EAPs), which have the ability to realize bending motion, contractile motion, extended motion and crawling motion under electric stimulation.
Recently, the increasing interest in underwater exploration motivates the development of aquatic unmanned vehicles. To execute hazardous tasks in an unknown or even hostile environment, researchers have directed on developing biomimetic robots inspired by the extraordinary maneuverability, cruising speed, and propulsion efficiency of fish. Nevertheless, the performance of current prototypes still has gaps compared with that of real fishes. In this review, recent approaches in structure designs, actuators, and sensors are presented. In addition, the theoretical methods for modeling the robotic fishes are consolidated, and the control strategies are offered. Finally, the current challenges are summarized, and possible future directions are deeply discussed. It is expected that the emergence of new engineering and biological technologies will enhance the field of robotic fish for further advancement.
Plasticized polyvinyl chloride (PVC) gel and mesh electrode-based soft actuators have considerable potential to provide new types of artificial muscle, exhibiting similar responsiveness to biological muscle in air, >10% deformation, >90 kPa output stress, variable stiffness, long cycle life (>5 million cycles), and low power consumption. We have designed and fabricated a prototype of walking assist wear using the PVC gel actuator in previous study. The system has several advantages compared with traditional motor-based exoskeletons, including lower weight and power consumption, and no requirement for rigid external structures that constrain the wearer’s joints. In this study, we designed and established a control and power system to making the whole system portable and wearable outdoors. And we designed two control strategies based on the characteristics of the assist wear and the biological kinematics. In a preliminary experimental evaluation, a hemiparetic stroke patient performed a 10 m to-and-fro straight line walking task with and without assist wear on the affected side. We found that the assist wear enabled natural movement, increasing step length and decreasing muscular activity during straight line walking. We demonstrated that the assistance effect could be adjusted by controlling the on-off time of the PVC gel soft actuators. The results show the effectiveness of the proposed system and suggest the feasibility of PVC gel soft actuators for developing practical soft wearable assistive devices, informing the development of future wearable robots and the other soft actuator technologies for human movement assistance and rehabilitation.
20 December 2024 in Advances in Colloid and Interface Science