Chiara Malloggi

Dr. Chiara Malloggi

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DPDaniele Pezzoli
Daniele Pezzoli
FOFrancesca Olimpieri
Francesca Olimpieri
CMChiara Malloggi
Chiara Malloggi
SBSabrina Bertini
Sabrina Bertini
ALESSANDRO VOLONTERIOALESSANDRO VOLONTERIO
ALESSANDRO VOLONTERIO
Gabriele CandianiGabriele Candiani
Gabriele Candiani
Successful non-viral gene delivery currently requires compromises to achieve useful transfection levels while minimizing toxicity. Despite high molecular weight (MW) branched polyethylenimine (bPEI) is considered the gold standard polymeric transfectant, it suffers from high cytotoxicity. Inversely, its low MW counterpart is less toxic and effective in transfection. Moreover, chitosan is a highly biocompatible and biodegradable polymer but characterized by very low transfection efficiency. In this scenario, a straightforward approach widely exploited to develop effective transfectants relies on the synthesis of chitosan-graft-low MW bPEIs (Chi-g-bPEIx) but, despite the vast amount of work that has been done in developing promising polymeric assemblies, the possible influence of the degree of grafting on the overall behavior of copolymers for gene delivery has been largely overlooked. With the aim of providing a comprehensive evaluation of the pivotal role of the degree of grafting in modulating the overall transfection effectiveness of copolymeric vectors, we have synthesized seven Chi-g-bPEIx derivatives with a variable amount of bPEI grafts (minimum: 0.6%; maximum: 8.8%). Along the Chi-g-bPEIx series, the higher the degree of grafting, the greater the ζ-potential and the cytotoxicity of the resulting polyplexes. Most important, in all cell lines tested the intermediate degree of grafting of 2.7% conferred low cytotoxicity and higher transfection efficiency compared to other Chi-g-bPEIx copolymers. We emphasize that, in transfection experiments carried out in primary articular chondrocytes, Chi-g-bPEI2.7% was as effective as and less cytotoxic than the gold standard 25 kDa bPEI. This work underlines for the first time the pivotal role of the degree of grafting in modulating the overall transfection effectiveness of Chi-g-bPEIx copolymers. Crucially, we have demonstrated that, along the copolymer series, the fine tuning of the degree of grafting directly affected the overall charge of polyplexes and, altogether, had a direct effect on cytotoxicity.

4 November 2013 in Bioconjugate Chemistry
Verified
Journal Article
Closed access
AGAlessandra Ghilardi
Alessandra Ghilardi
DPDaniele Pezzoli
Daniele Pezzoli
MBMaria Cristina Bellucci
Maria Cristina Bellucci
CMChiara Malloggi
Chiara Malloggi
ANArmando Negri
Armando Negri
ALESSANDRO VOLONTERIOALESSANDRO VOLONTERIO
ALESSANDRO VOLONTERIO

22 July 2015 in Polymer Chemistry
Verified
Journal Article
Open access
PDF file
CMChiara Malloggi
Chiara Malloggi
DPD. Pezzoli
D. Pezzoli
LLuca Magagnin
Luca Magagnin
LNL. De Nardo
L. De Nardo
DMDiego Mantovani
Diego Mantovani
Gabriele CandianiGabriele Candiani
Gabriele Candiani
Cationic polymers are amongst the most utilized non-viral vectors for gene transfer owing to their ability to condense and protect the genetic material within polyplexes and to ferry it into cells. Quite a number of parameters, both related to the features of the vectors themselves (e.g. degree of branching, molecular weight, polydispersity) and to polyplexes (e.g. nitrogen to phosphate ratio (N/P), dose of complexes delivered, complexation buffer, etc.), are known to affect transfection behaviour. Consequently, some substantial discrepancy found in raw materials and in-home protocols across laboratories account for some disagreement and conflicting data about their performance. Hereinafter we provide a thorough chemical-physical and in vitro biochemical characterization, comparison, and optimization of the most widely used, commercially sourced polymers used in transfection, namely linear polyethylenimines (lPEIs), branched PEIs (bPEIs), linear poly-L-lysines (lPLLs), and polyamidoamine dendrimers (dPAMAMs). By means of a stepwise approach, we pinpointed the most effective molecular weight and complexation conditions specific to each of them and correlated the physicochemical features of polyplexes with their transfection effectiveness. Besides, taking separately into account the effects on transfection of the plasmid dose delivered to cells, the cell seeding density and the volume of the culture medium, we highlited a range of optimal conditions roughly specific to each studied polymer. Finally, we coped with the effect of the variation of these three parameters at once on the transfection effectiveness of lPEI and bPEI and pinpointed an array of settings specifically optimized to attain truly superior performances.

1 December 2017 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
RCRenato Casana
Renato Casana
VTValerio Tolva
Valerio Tolva
AOAndrea Odero
Andrea Odero
CMChiara Malloggi
Chiara Malloggi
APAldo Paolucci
Aldo Paolucci
VSVincenzo Silani
Vincenzo Silani

29 April 2014 in Chemistry – A European Journal
Verified
Journal Article
Closed access
PDF file
Caterina ViglianisiCaterina Viglianisi
Caterina Viglianisi
VPVeronica Di Pilla
Veronica Di Pilla
Stefano MenichettiStefano Menichetti
Stefano Menichetti
VRVincent M. Rotello
Vincent M. Rotello
Gabriele CandianiGabriele Candiani
Gabriele Candiani
Riccardo AmoratiRiccardo Amorati
Riccardo Amorati

28 February 2018 in Vascular
Verified
Journal Article
Closed access
RCRenato Casana
Renato Casana
VTValerio Stefano Tolva
Valerio Stefano Tolva
AOAndrea Odero
Andrea Odero
CMChiara Malloggi
Chiara Malloggi
GPGianfranco Parati
Gianfranco Parati
Purpose: Endovascular ablation of the great saphenous vein has been proposed as a less invasive alternative to conventional ligation and stripping of varicose veins. Outcomes of patients treated with the radiofrequency ablation ClosureFast™ system over an eight-year period from a single-center were evaluated. Methods: Three-year follow-up data included duplex ultrasound scan, complication rate, and questionnaires to assess patients’ QOL, level of pain, and days off work. Results: A total of 1080 consecutive patients (49.5 ± 18.6 years, 72% female, mean body mass index: 25.44 ± 4.1 kg m−2) underwent radiofrequency ablation for incompetent saphenous veins in a single institution. Occlusion of the great saphenous vein was obtained in 98.6% and 93.8% cases at the end of the procedures and within 36 months, respectively. Only three deep venous thromboses and minor complications occurred in this series throughout the first week from the procedure. A decrease of the external vein diameter, equal to 72.7% and 31.1% of the pretreatment diameter, was observed at 1 week and 36 months, respectively. The average Aberdeen Varicose Vein Questionnaire score improved from 18.06 ± 9.47 before treatment to 11.56 ± 10.23 at 12 months, with no significant differences in the subsequent follow-up. SF-36 QOL scores significantly improved after the procedure in all domains, while there were no changes over time. Patients reported a prompt return to normal daily activities (1.5 ± 0.7 days) and work (3.1 ± 1.9 days). Body mass index influenced QOL scores, while it did not affect great saphenous vein diameter reduction during the follow-up. On the contrary, Clinical Etiologic Anatomic Pathophysiologic class significantly influenced both great saphenous vein diameter reduction after the treatment and QOL scores within 36 months. Conclusion: Results of this retrospective monocentric, large patients study suggest that radiofrequency ablation of the great saphenous vein may be a safe and efficient alternative to conventional surgery.