Yiwei He

Dr. Yiwei He

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
WGWeihong Guo
Weihong Guo
YHYiwei He
Yiwei He
This study argues that medical data should be better utilized and attention should be paid to the patient’s visual experience during their journey to the emergency department (ED). Wayfinding in medical settings remains a challenge for patients. One reason is that decision makers do not adequately understand what the patients have seen and been through during their journey in the ED built environment, which leads to inaccurate selection and misplacement of signage. This study claims that there is still room to optimize existing wayfinding design methods. This study selected a representative large-scale general hospital in China, collected the annual healthcare information system (HIS) data of ED patients in 2021, and reproduced the clinical process of ED patients in the form of a probability treemap through categorical analysis. Furthermore, Massmotion was used to simulate the patient’s journey and obtain their vision focus area (VFA). With the VFA and field observation record, the research targeted 17 wall surfaces in the ED built environment. On the basis of the comparative analysis, we found the misplacement of the current signage system and the direction of future optimization. This method can provide a reference for designers during their decision-making process to aim for an efficient wayfinding system.

30 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
WBWenqi Bai
Wenqi Bai
WGWeihong Guo
Weihong Guo
YHYiwei He
Yiwei He
YWYudi Wu
Yudi Wu
SLSheng Liang
Sheng Liang
SZShen Zhang
Shen Zhang
The atrium, as the core space of modern university libraries, is crucial for providing ample natural lighting and creating a comfortable spatial experience. It is also key to achieving the building’s green and low-carbon goals. However, designing the atrium of a university library faces a significant challenge: finding the right balance between ensuring good natural lighting and effectively reducing the energy consumption of the air conditioning system. This study aims to explore this balance and provide architects with various feasible design schemes. Firstly, a parametric typical model of the atrium space was established by researching 36 university libraries. Based on the Grasshopper platform in Rhino, the typical model was simulated for natural lighting and energy consumption, and the Wallacei plugin was used to couple the optimization parameters of the typical model with the optimization target parameters. The multi-objective optimization experiment of the typical model was carried out with the objectives of maximizing spatial daylight autonomy and the percentage of useful daylight illuminance, as well as minimizing air conditioning energy consumption. The experiment generated 2000 optimization solutions, and the analysis of the historical solution set revealed the complex non-linear relationship between optimization parameters and performance indicators. Moreover, three Pareto optimal solutions were selected as representative design schemes, providing valuable references for architects when designing the spatial form of the atrium.

12 April 2024 in Buildings
Verified
Journal Article
Open access
PDF file
WBWenqi Bai
Wenqi Bai
YWYudi Wu
Yudi Wu
YHYiwei He
Yiwei He
LWLi Wang
Li Wang
ZQZining Qiu
Zining Qiu
YYYuqi Ye
Yuqi Ye
In the early stage of architectural design, addressing the challenges posed by negative spaces in high-density urban environments is crucial for enhancing spatial efficiency and building sustainability. Multiple studies employed digital methods and tools to address these issues, such as parametric design, simulation, and genetic algorithms, to investigate architectural generation approaches for urban negative spaces. This article proposes an integrated design process that involves finding the location and form of negative spaces, generating solutions using slime mold and wasp algorithms, and optimizing and analyzing solutions using the Wallacei plugin in Grasshopper. This comprehensive approach underscores the potential of parametric design to yield a multitude of solutions while also acknowledging the convergence challenges encountered during simulations, particularly in optimizing for optimal sunlight exposure during the winter solstice and minimal solar radiation in the summer. Analyzing the optimization goals and parameter values of the 15th Pareto optimal solution in the 100th generation reveals: (1) a higher number of units leads to positive correlation growth in both objectives; (2) within a certain number of units, parametrically generated solutions facilitate the convergence of optimization goals, yielding optimal outcomes. Therefore, factors such as the range of unit quantities and proportions need consideration during early-stage parametric design and simulation. This study explores a design methodology for negative spaces in high-density urban cities, validating the feasibility of various mainstream generation methods and offering insights for future research.

28 June 2026 in Buildings
Verified
Journal Article
Open access
PDF file
GZGuibin Zhang
Guibin Zhang
Wumin OuyangWumin Ouyang
Wumin Ouyang
ZFZhaohui Fan
Zhaohui Fan
XWXinyu Wang
Xinyu Wang
LWLi Wang
Li Wang
YHYiwei He
Yiwei He
In Guangzhou’s Shangxiajiu Pedestrian Street, street segments with higher billboard densities exhibited greater proportions of both brief stops and extended dwell, while segments with higher densities of illuminated signage at night also showed greater proportions of extended dwell. Higher street width-to-height ratios and greater ground-floor façade transparency were associated with increased afternoon pedestrian activity and brief stopping, respectively. Using 13 street segments as the units of analysis, this study combined on-site measurements, synchronized behavioral observations, and correlation analysis to examine the associations of billboard density, illuminated signage density, street width-to-height ratio, and façade transparency with brief stopping, extended dwell, and through-movement behavior. The results showed that billboard density was strongly and positively correlated with both the mean proportion of brief stops and the mean proportion of extended dwell (r = 0.749, p = 0.003; r = 0.832, p < 0.001). Illuminated signage density was also strongly and positively correlated with the proportion of extended dwell at night (r = 0.823, p = 0.001). Street width-to-height ratio was positively correlated with both the afternoon proportion of brief stops and the afternoon proportion of total pedestrian activity, while façade transparency was positively correlated with the afternoon and mean proportions of brief stops. These findings indicate that, in the case of Shangxiajiu Pedestrian Street, pedestrian dwell was more concentrated in street segments characterized by richer commercial information, greater nighttime visibility, more open spatial configurations, or more legible storefront interfaces. The findings provide field-based quantitative evidence to inform signage layout, ground-floor interface optimization, the coordination of street enclosure, and the management of nighttime visual environments in historic commercial streets.