Stephen E. Russek

Dr. Stephen E. Russek

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2018 in Science Advances
Verified
Journal Article
Open access
PDF file
MSMichael L. Schneider
Michael L. Schneider
CDChristine A. Donnelly
Christine A. Donnelly
SRStephen E. Russek
Stephen E. Russek
BBBurm Baek
Burm Baek
MPMatthew R. Pufall
Matthew R. Pufall
WRWilliam H. Rippard
William H. Rippard
Clustered ferromagnetic Josephson junctions form ultralow energy synaptic elements.

13 April 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KSKarl F. Stupic
Karl F. Stupic
MAMaureen Ainslie
Maureen Ainslie
MBMichael Boss
Michael Boss
CCCecil Charles
Cecil Charles
ADAndrew M. Dienstfrey
Andrew M. Dienstfrey
SRStephen E. Russek
Stephen E. Russek
Purpose: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density.Methods: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T1 and T2 mapping, image resolution, slice profile, and SNR.Results: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions.Conclusions: A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.

25 October 2018 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
MSMichael L. Schneider
Michael L. Schneider
CDChristine A. Donnelly
Christine A. Donnelly
SRStephen E. Russek
Stephen E. Russek
Josephson junctions and single flux quantum (SFQ) circuits form a natural neuromorphic technology with SFQ pulses and superconducting transmission lines simulating action potentials and axons. Josephson junctions consist of superconducting electrodes with nanoscale barriers that modulate the coupling of the complex superconducting order parameter across the junction. When the order parameter undergoes a 2π phase jump, the junction emits a voltage pulse with an integrated amplitude of a flux quantum ϕ0 = h/(2e) = 2.068 × 10−15 V s. The coupling across a junction can be controlled and modulated by incorporating the nanoscale magnetic structure in the barrier. The magnetic state of embedded nanoclusters can be changed by applying small current or field pulses, enabling both unsupervised and supervised learning. The advantage of this magnetic/superconducting technology is that it combines natural spiking behavior and plasticity in a single nanoscale device and is orders of magnitude faster and lower energy than other technologies. Maximum operating frequencies are above 100 GHz, while spiking and training energies are ∼10−20 J and 10−18 J, respectively. This technology can operate close to the thermal limit, which at 4 K is considerably lower energy than in a human brain. The transition from deterministic to stochastic behavior can be studied with small temperature modifications. Here, we present a tutorial on the spiking behavior of Josephson junctions; the use of the nanoscale magnetic structure to modulate the coupling across the junction; the design and operation of magnetic Josephson junctions, device models, and simulation of magnetic Josephson junction neuromorphic circuits; and potential neuromorphic architectures based on hybrid superconducting/magnetic technology.

8 August 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XYXiaolu Yin
Xiaolu Yin
SRStephen E. Russek
Stephen E. Russek
GZGary Zabow
Gary Zabow
FSFan Sun
Fan Sun
JMJeotikanta Mohapatra
Jeotikanta Mohapatra
JMJohn Moreland
John Moreland
Superparamagnetic iron oxide nanoparticles (SPIONs) are widely investigated and utilized as magnetic resonance imaging (MRI) contrast and therapy agents due to their large magnetic moments. Local field inhomogeneities caused by these high magnetic moments are used to generate T2 contrast in clinical high-field MRI, resulting in signal loss (darker contrast). Here we present strong T1 contrast enhancement (brighter contrast) from SPIONs (diameters from 11 nm to 22 nm) as observed in the ultra-low field (ULF) MRI at 0.13 mT. We have achieved a high longitudinal relaxivity for 18 nm SPION solutions, r1 = 615 s−1 mM−1, which is two orders of magnitude larger than typical commercial Gd-based T1 contrast agents operating at high fields (1.5 T and 3 T). The significantly enhanced r1 value at ultra-low fields is attributed to the coupling of proton spins with SPION magnetic fluctuations (Brownian and Néel) associated with a low frequency peak in the imaginary part of AC susceptibility (χ”). SPION-based T1-weighted ULF MRI has the advantages of enhanced signal, shorter imaging times, and iron-oxide-based nontoxic biocompatible agents. This approach shows promise to become a functional imaging technique, similar to PET, where low spatial resolution is compensated for by important functional information.

11 October 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
ESEddy Solomon
Eddy Solomon
GLGregory Lemberskiy
Gregory Lemberskiy
SBSteven Baete
Steven Baete
KHKenneth Hu
Kenneth Hu
DMDariya Malyarenko
Dariya Malyarenko
GKGene Kim
Gene Kim

9 February 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
KRKatherine P. Rice
Katherine P. Rice
SRStephen E. Russek
Stephen E. Russek
RGRoy H. Geiss
Roy H. Geiss
JSJustin M. Shaw
Justin M. Shaw
RURobert J. Usselman
Robert J. Usselman
YIYves U. Idzerda
Yves U. Idzerda
High quality 5 nm cubic Tb-doped magnetite nanoparticles have been synthesized by a wet-chemical method to investigate tailoring of magnetic properties for imaging and biomedical applications. We show that the Tb is incorporated into the octahedral 3+ sites. High-angle annular dark-field microscopy shows that the dopant is well-distributed throughout the particle, and x-ray diffraction measurements show a small lattice parameter shift with the inclusion of a rare-earth dopant. Magnetization and x-ray magnetic circular dichroism data indicate that the Tb spins are unpolarized and weakly coupled to the iron spin lattice at room temperature, and begin to polarize and couple to the iron oxide lattice at temperatures below 50 K. Broadband ferromagnetic resonance measurements show no increase in magnetic damping at room temperature for Tb-doped nanoparticles relative to undoped nanoparticles, further confirming weak coupling between Fe and Tb spins at room temperature. The Gilbert damping constant, α, is remarkably low for the Tb-doped nanoparticles, with α = 0.024 ± 0.003. These nanoparticles, which have a large fixed moment, a large fluctuating moment and optically active rare-earth elements, are potential high-relaxivity T1 and T2 MRI agents with integrated optical signatures.