Erica Magagnini

Dr. Erica Magagnini

Department of Construction, Civil Engineering and Architecture, Polytechnic University of Marche, Ancona, Italy
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2021 in Metals and Materials International
Verified
Journal Article
Closed access
PDF file
AOAbdelmoumin Ouladbrahim
Abdelmoumin Ouladbrahim
IBIdir Belaidi
Idir Belaidi
SKSamir Khatir
Samir Khatir
Erica MagagniniErica Magagnini
Erica Magagnini
Roberto CapozuccaRoberto Capozucca
Roberto Capozucca
Magd Abdel WahabMagd Abdel Wahab
Magd Abdel Wahab

7 April 2023 in Buildings
Verified
Journal Article
Open access
PDF file
EBElisa Bettucci
Elisa Bettucci
Roberto CapozuccaRoberto Capozucca
Roberto Capozucca
Erica MagagniniErica Magagnini
Erica Magagnini
MVMaria Vittoria Vecchietti
Maria Vittoria Vecchietti
This paper intends to deepen the topic of damage detection based on non-destructive tests (NDT) for the assessment of the dynamic behavior of RC beams damaged and strengthened both with near-surface mounted (NSM) Carbon and GlassFRP rods. The NSM strengthening with fiber-reinforced polymer (FRP) rods of damaged reinforced concrete (RC) beams is a viable alternative to the traditional strengthening with externally bonded (EB) FRP strips or sheets. In this paper, static tests were foreseen on RC beams to create cracking, and successively, the RC beams strengthened with NSM CFRP and GFRP rods were still investigated using free vibration tests at different loading levels until failure. The purpose of this research is to compare the response of two different types of strengthening of damaged RC beams based on the strength of CFRP and GFRP rods until failure modes. At different steps of loading, the behavior of beams under experimental vibrations has been monitored by frequency response function (FRF) diagrams. Finally, a discussion of the results is presented.

1 May 2017 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
Roberto CapozuccaRoberto Capozucca
Roberto Capozucca
Erica MagagniniErica Magagnini
Erica Magagnini
Among the methods of monitoring of integrity, vibration analysis is more convenient as non-destructive testing (NDT) method. Many aspects regarding the vibration monitoring of the structural integrity of damaged RC elements have not been completely analysed in literature. The correlation between the development of the crack pattern on concrete surface under bending loadings, as well as the width and depth of cracks, and the variation of dynamic parameters on a structural element is an important aspects that has to be more investigated. This paper deals with cracked RC beams controlled by NDT based on natural vibration, which may be correlated to damage degree due to cracking of concrete under severe state of loading. An experimental investigation on the assessment of RC beams in different scale under loading has been done through dynamic tests in different constraint conditions of edges measuring frequency values and frequency variation. Envelope of Frequency Response Functions (FRFs) are shown and the changes of natural frequency values are related to the damage degree of RC beams subjected to static tests. Finally, a comparison between data obtained by finite element analysis and experimental results is shown.

5 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Erica MagagniniErica Magagnini
Erica Magagnini
Vanni NicolettiVanni Nicoletti
Vanni Nicoletti
Fabrizio GaraFabrizio Gara
Fabrizio Gara
The failure behaviour of historic unreinforced masonry (URM) structures is strongly influenced by the properties of bricks and mortar. Over time, degradation processes compromise these materials, with significant effect on structural response and safety. Nevertheless, deterioration effects on the nonlinear behaviour of masonry have been only marginally investigated. This study investigates the mechanical behaviour and failure mechanisms of historic brick masonry with weak and irregular mortar joints, representative of Mediterranean traditional constructions. An extensive experimental programme was conducted on mortars, historic clay bricks, prisms, wallets, and triplet specimens, complemented by in-situ flat jack tests. Results confirm the critical role of mortar quality and joint irregularities in reducing compressive and shear strength and in influencing deformation capacity of historic masonry. The experimental findings served as a basis for the calibration of a Finite Element Model (FEM), subsequently employed to gain deeper insight into the governing failure mechanisms in a real study case. A critical discussion of compression and shear failure criteria is presented, focusing on historic masonry. Experimental and analytical comparisons show major discrepancies in classical criteria, especially with degraded mortars. The study shows that in historic masonry with weak joints, failure is often governed by compression rather than shear.

Verified
Journal Article
Open access
PDF file
Erica MagagniniErica Magagnini
Erica Magagnini
EBElisa Bettucci
Elisa Bettucci
Basalt fiber-reinforced polymer (BFRP) composites are increasingly considered as a sustainable alternative to traditional FRP systems for the strengthening of reinforced concrete (RC) structures, owing to their favorable mechanical properties, durability, and lower environmental impact. This study investigates the effectiveness of externally bonded BFRP strips for the strengthening of RC beam–column joints, with particular attention to the influence of strengthening layout on the structural response. An experimental program was carried out on full-scale RC beam–column joint specimens subjected to monotonic loading with load–unload cycles of increasing amplitude. Each specimen was first tested in its original configuration to induce controlled damage and subsequently strengthened using BFRP strips arranged according to two different layouts. This approach enabled a direct comparison between the behaviour of pre-damaged and retrofitted specimens and allowed the contribution of the BFRP reinforcement to be clearly identified. BFRP strengthening markedly improves joint performance, enhancing strength, ductility, and energy dissipation while limiting stiffness degradation. The results underline the critical role of the strengthening layout in governing the effectiveness of the composite system, as well as the influence of substrate cracking in the activation of the BFRP reinforcement.

1 October 2025
Verified
Book Chapter
Closed access
PDF file
Erica MagagniniErica Magagnini
Erica Magagnini
AKAbdelwahhab Khatir
Abdelwahhab Khatir
RCRoberto Capozucca
Roberto Capozucca