재민 이

Prof. Dr. 재민 이

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Korean Medical Science
Verified
Journal Article
Open access
HPHye Ran Park
Hye Ran Park
KPKwang-Woo Park
Kwang-Woo Park
재이재민 이
재민 이
JKJung Hoon Kim
Jung Hoon Kim
SJSang Soon Jeong
Sang Soon Jeong
SPSun Ha Paek
Sun Ha Paek
Park HR, et al. J Korean Med Sci. 2019 Feb;34(8):e57. https://doi.org/10.3346/jkms.2019.34.e57

21 September 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HPHye Ran Park
Hye Ran Park
YLYong Hoon Lim
Yong Hoon Lim
ESEun Jin Song
Eun Jin Song
재이재민 이
재민 이
KPKawngwoo Park
Kawngwoo Park
SPSun Ha Paek
Sun Ha Paek
Bilateral subthalamic nucleus (STN) Deep brain stimulation (DBS) is a well-established treatment in patients with Parkinson’s disease (PD). Traditionally, STN DBS for PD is performed by using microelectrode recording (MER) and/or intraoperative macrostimulation under local anesthesia (LA). However, many patients cannot tolerate the long operation time under LA without medication. In addition, it cannot be even be performed on PD patients with poor physical and neurological condition. Recently, it has been reported that STN DBS under general anesthesia (GA) can be successfully performed due to the feasible MER under GA, as well as the technical advancement in direct targeting and intraoperative imaging. The authors reviewed the previously published literature on STN DBS under GA using intraoperative imaging and MER, focused on discussing the technique, clinical outcome, and the complication, as well as introducing our single-center experience. Based on the reports of previously published studies and ours, GA did not interfere with the MER signal from STN. STN DBS under GA without intraoperative stimulation shows similar or better clinical outcome without any additional complication compared to STN DBS under LA. Long-term follow-up with a large number of the patients would be necessary to validate the safety and efficacy of STN DBS under GA.

21 November 2017 in European Radiology
Verified
Journal Article
Closed access
PDF file
KPKyoungjune Pak
Kyoungjune Pak
KKKeunyoung Kim
Keunyoung Kim
MLMyung-jun Lee
Myung-jun Lee
재이재민 이
재민 이
BKBum Soo Kim
Bum Soo Kim
IKIn Joo Kim
In Joo Kim

1 January 2021 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
KPKawngwoo Park
Kawngwoo Park
KPKwang Hyon Park
Kwang Hyon Park
HPHye Ran Park
Hye Ran Park
재이재민 이
재민 이
YKYong Hwy Kim
Yong Hwy Kim
SPSun Ha Paek
Sun Ha Paek
Park K, et al. J Korean Med Sci. 2021 Mar;36(15):e97. https://doi.org/10.3346/jkms.2021.36.e97

30 April 2022 in Journal of Yeungnam Medical Science
Verified
Journal Article
Open access
PDF file
JLJung Hwan Lee
Jung Hwan Lee
재이재민 이
재민 이
JHJaehyun Hwang
Jaehyun Hwang
JPJoo Young Park
Joo Young Park
MKMijeong Kim
Mijeong Kim
IHIn Ho Han
In Ho Han
Background: Recently, there have been various developments in medical service robots (MSRs). However, few studies have examined the perceptions of those who use it. The purpose of this study is to identify user perceptions of MSRs.Methods: We conducted a survey of 320 patients, doctors, and nurses. The contents of the survey were organized as follows: external appearances, perceptions, expected utilization, possible safety accidents, and awareness of their responsibilities. Statistical analyses were performed using t-test, chi-square test, and analysis of variance.Results: The most preferred appearance was the animal type, with a screen. The overall average score of positive questions was 3.64±0.98 of 5 points and that of negative questions was 3.24±0.99. Thus, the results revealed that the participants had positive perceptions of MSR. The overall average of all expected utilization was 4.05±0.84. The most expected utilization was to guide hospital facilities. The most worrisome accident was exposure to personal information. Moreover, participants thought that the overall responsibility of the robot user (hospital) was greater than that of the robot manufacturer in the case of safety accidents.Conclusion: The perceptions of MSRs used in hospital wards were positive, and the overall expected utilization was high. It is necessary to recognize safety accidents for such robots, and sufficient attention is required when developing and manufacturing robots.

1 January 2021 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
HSHyok Ki Shim
Hyok Ki Shim
재이재민 이
재민 이
DKDong Hwan Kim
Dong Hwan Kim
KNKyoungHyup Nam
KyoungHyup Nam
BCByung Kwan Choi
Byung Kwan Choi
IHIn Ho Han
In Ho Han
Objective : Intraoperative neurophysiological monitoring (IONM) has been widely used during spine surgery to reduce or prevent neurologic deficits, however, its application to the surgical management for cervical myelopathy remains controversial. This study aimed to assess the success rate of IONM in patients with cervical myelopathy and to investigate the factors associated with successful baseline monitoring and the effect of increasing the stimulation intensity by focusing on motor evoked potentials (MEPs). Methods : The data of 88 patients who underwent surgery for cervical myelopathy with IONM between January 2016 and June 2018 were retrospectively reviewed. The success rate of baseline MEP monitoring at the initial stimulation of 400 V was investigated. In unmonitorable cases, the stimulation intensity was increased to 999 V, and the success rate final MEP monitoring was reinvestigated. In addition, factors related to the success rate of baseline MEP monitoring were investigated using independent t-test, Wilcoxon rank-sum test, chi-squared test, and Fisher's exact probability test for statistical analysis. The factors included age, sex, body mass index, diabetes mellitus, smoking history, symptom duration, Torg-Pavlov ratio, space available for the cord (SAC), cord compression ratio (CCR), intramedullary increased signal intensity (SI) on magnetic resonance imaging, SI length, SI ratio, the Medical Research Council (MRC) grade, the preoperative modified Nurick grade and Japanese Orthopedic Association (JOA) score. Results : The overall success rate for reliable MEP response was 52.3% after increasing the stimulation intensity. No complications were observed to be associated with increased intensity. The factors related to the success rate of final MEP monitoring were found to be SAC (p<0.001), CCR (p<0.001), MRC grade (p<0.001), preoperative modified Nurick grade (p<0.001), and JOA score (p<0.001). The cut-off score for successful MEP monitoring was 5.67 mm for SAC, 47.33% for the CCR, 3 points for MRC grade, 2 points for the modified Nurick grade, and 12 points for the JOA score. Conclusion : Increasing the stimulation intensity could significantly improve the success rate of baseline MEP monitoring for unmonitorable cases at the initial stimulation in cervical myelopathy. In particular, the SAC, CCR, MRC grade, preoperative Nurick grade and JOA score may be considered as the more important related factors associated with the success rate of MEP monitoring. Therefore, the degree of preoperative neurological functional deficits and the presence of spinal cord compression on imaging could be used as new detailed criteria for the application of IONM in patients with cervical myelopathy.