Parkinson's disease (PD) is a degenerative disorder of the brain characterized by the impairment of the nigrostriatal system. This impairment leads to specific motor manifestations (i.e., bradykinesia, tremor, and rigidity) that are assessed through clinical examination, scales, and patient-reported outcomes. New sensor-based and wearable technologies are progressively revolutionizing PD care by objectively measuring these manifestations and improving PD diagnosis and treatment monitoring. However, their use is still limited in clinical practice, perhaps because of the absence of external validation and standards for their continuous use at home. In the near future, these systems will progressively complement traditional tools and revolutionize the way we diagnose and monitor patients with PD.
Accurate blood-based biomarkers of Alzheimer's disease (AD) could constitute simple, inexpensive, and non-invasive tools for the early diagnosis and treatment of this devastating neurodegenerative disease. We sought to develop a robust AD biomarker panel by identifying alterations in plasma metabolites that persist throughout the continuum of AD pathophysiology. Using a multicenter, cross-sectional study design, we based our analysis on metabolites whose levels were altered both in AD patients and in patients with amnestic mild cognitive impairment (aMCI), the earliest identifiable stage of AD. UPLC coupled to mass spectrometry was used to independently compare the levels of 495 plasma metabolites in aMCI (n = 58) and AD (n = 100) patients with those of normal cognition controls (NC, n = 93). Metabolite alterations common to both aMCI and AD patients were used to generate a logistic regression model that accurately distinguished AD from NC patients. The final panel consisted of seven metabolites: three amino acids (glutamic acid, alanine, and aspartic acid), one non-esterified fatty acid (22:6n-3, DHA), one bile acid (deoxycholic acid), one phosphatidylethanolamine [PE(36:4)], and one sphingomyelin [SM(39:1)]. Detailed analysis ruled out the influence of potential confounding variables, including comorbidities and treatments, on each of the seven biomarkers. The final model accurately distinguished AD from NC patients (AUC, 0.918). Importantly, the model also distinguished aMCI from NC patients (AUC, 0.826), indicating its potential diagnostic utility in early disease stages. These findings describe a sensitive biomarker panel that may facilitate the specific detection of early-stage AD through the analysis of plasma samples.
Introduction: Inertial measurement units (IMUs) positioned on various body locations allow detailed gait analysis even under unconstrained conditions. From a medical perspective, the assessment of vulnerable populations is of particular relevance, especially in the daily-life environment. Gait analysis algorithms need thorough validation, as many chronic diseases show specific and even unique gait patterns. The aim of this study was therefore to validate an acceleration-based step detection algorithm for patients with Parkinson’s disease (PD) and older adults in both a lab-based and home-like environment. Methods: In this prospective observational study, data was captured from a single 6-degrees of freedom IMU (APDM) (3-DOF accelerometer and 3-DOF gyroscope) worn on the lower back. Detection of heel strike (HS) and toe off (TO) on a treadmill was validated against an optoelectronic system (Vicon) (11 PD patients and 12 older adults). A second independent validation study in the home-like environment was performed against video observation (20 PD patients and 12 older adults) and included step counting during turning and non-turning, defined with a previously published algorithm. Results: A continuous-wavelet-transform (cwt) based algorithm was developed for step detection with very high agreement with the optoelectronic system. HS detection in PD patients/older adults, respectively, reached 99%/99% accuracy. Similar results were obtained for TO (99%/100%). In HS detection, Bland-Altman plots showed a mean difference of 0.002s (95% Confidence Interval (CI) -0.09 to 0.10) between the algorithm and the optoelectronic system. The Bland-Altman plot for TO detection showed mean differences of 0.00s (95% CI -0.12 to 0.12). In the home-like assessment, the algorithm for detection of occurrence of steps during turning reached 90% (PD patients)/90% (older adults) sensitivity, 83%/88% specificity and 88%/89% accuracy. The detection of steps during non-turning phases reached 91%/91% sensitivity, 90%/90% specificity and 91%/91% accuracy. Conclusion: This continuous-wavelet-transform based algorithm for step detection from accelerations measured at the lower back is in high agreement with the optoelectronic system in both PD patients and older adults. This approach and algorithm thus could provide a valuable tool for future research on home-based gait analysis in these vulnerable cohorts.