Purpose: To compare the safety and efficacy of microshunt implantation augmented with Mitomycin C in patients with pseudoexfoliation glaucoma (PEXG) and primary open-angle glaucoma (POAG). Methods: In this retrospective, single centre, interventional study, 46 eyes of 41 patients with PEXG (20 eyes) and POAG (26 eyes) underwent microshunt implantation. Definition of failure was an intraocular pressure (IOP) lower than 5 or higher than 17mmHg on two consecutive visits, an IOP reduction lower than 20% on two consecutive visits, the need of surgical revisions or reoperations or loss of light perception. Outcome was rated as complete success if achieved without medication, otherwise as qualified success. Furthermore, postoperative complications and interventions were compared between the two groups. Results: Patient demographics were similar, except for older age in the PEXG group (70.9±8.6 versus 77.6±8; p = 0.02). Mean IOP dropped from 21.5±5.8mmHg (PEXG) and 18.2±4.5mmHg (POAG) at baseline to 12.8±3.0mmHg (p<0.0001) and 12.9±4.2mmHg (p<0.0001), respectively, at one year. Mean number of medications were reduced from 2.8±1.3 to 0.3±0.8 for PEXG patients (p<0.0001) and from 2.7±1.3 to 0.3±0.8 for POAG patients (p<0.0001). At one year of follow-up 75.0% of PEXG patients achieved complete success and 80.0% qualified success. In the POAG group rates were 73.1% and 76.9%, respectively. Postoperative complications were comparable between both groups, except for higher rates of hypotony (p = 0.04) and choroidal detachment (p = 0.03) in the PEXG group. Conclusion: Microshunt implantation demonstrated similar efficacy results in PEXG and POAG eyes at a follow-up of 12 months. Higher rates of transient hypotony and choroidal detachment were observed in PEXG eyes.
To analyze the protein profile of human vitreous of untreated patients with retinal vein occlusion (RVO). Sixty-eight vitreous humor (VH) samples (44 from patients with treatment naïve RVO, 24 controls with idiopathic floaters) were analyzed in this clinical-experimental study using capillary electrophoresis coupled to mass spectrometer and tandem mass spectrometry. To define potential candidate protein markers of RVO, proteomic analysis was performed on RVO patients (n = 30) and compared with controls (n = 16). To determine validity of potential biomarker candidates in RVO, receiver operating characteristic (ROC) was performed by using proteome data of independent RVO (n = 14) and control samples (n = 8). Ninety-four different proteins (736 tryptic peptides) could be identified. Sixteen proteins were found to be significant when comparing RVO and control samples (P = 1.43E-05 to 4.48E-02). Five proteins (Clusterin, Complement C3, Ig lambda-like polypeptide 5 (IGLL5), Opticin and Vitronectin), remained significant after using correction for multiple testing. These five proteins were also detected significant when comparing subgroups of RVO (central RVO, hemi-central RVO, branch RVO) to controls. Using independent samples ROC-Area under the curve was determined proving the validity of the results: Clusterin 0.884, Complement C3 0.955, IGLL5 1.000, Opticin 0.741, Vitronectin 0.786. In addition, validation through ELISA measurements was performed. The results of the study reveal that the proteomic composition of VH differed significantly between the patients with RVO and the controls. The proteins identified may serve as potential biomarkers for pathogenesis induced by RVO.
This retrospective, single-center study evaluates the safety and efficacy of PreserfloTM MicroShunt (MicroShunt) implantations compared to trabeculectomies (TETs) in patients diagnosed with pseudoexfoliation glaucoma (PEXG). A total of 31 eyes from 28 patients received a MicroShunt implantation, and 29 eyes from 26 patients received a TET. Surgical success was defined as an intraocular pressure (IOP) between 5 mmHg and 17 mmHg at the end of the follow-up period, no need for surgical revisions or secondary glaucoma surgery, and no loss of light perception. In the MicroShunt group, the mean IOP dropped from 20.8 ± 5.9 mmHg at baseline to 12.4 ± 2.8 mmHg (p < 0.0001) after one year. In the TET group, the mean IOP dropped from 22.3 ± 6.5 mmHg to 11.1 ± 3.7 mmHg (p < 0.0001) after 12 months. In both of the groups, the mean number of medications was reduced significantly (MicroShunt from 2.7 ± 1.2 to 0.2 ± 0.7; p < 0.0001 vs. TET from 2.9 ± 1.2 to 0.3 ± 0.9; p < 0.0001). Considering the success rates, 83.9% of the MicroShunt eyes achieved complete success, and 90.3% qualified for success at the end of the follow-up period. In the TET group, the rates were 82.8% and 93.1%, respectively. The postoperative complications were comparable between both groups. In conclusion, the MicroShunt implantation demonstrated non-inferiority regarding its efficacy and safety profile compared to TET in PEXG at a follow-up of one year.
14 August 2019 in Klinische Monatsblätter für Augenheilkunde
Zusammenfassung: Das Pseudoexfoliationssyndrom (PEX-Syndrom) ist eine häufige, mit dem Alter zunehmende und weltweit auftretende Erkrankung. Charakteristisch ist die Produktion und Ablagerung von extrazellulärem, fibrillärem Material im Bereich der vorderen Augenkammer. Mit einem breiten Spektrum potenzieller Komplikationen ist die Relevanz sowohl für die konservative als auch die operative Ophthalmologie groß.
6 September 2023 in Klinische Monatsblätter für Augenheilkunde
Purpose To compare two glaucoma drainage devices with subconjunctival filtration (MicroShunt and XEN) for open-angle glaucoma (OAG), with respect to effectiveness and safety. Patients and Methods This is a single center, retrospective, interventional study. In total, 106 eyes of 95 patients with OAG underwent surgery. Of these patients, 51 eyes of 45 patients received a MicroShunt implantation and 55 eyes of 50 patients received an XEN implantation. Failure was defined as an intraocular pressure (IOP) lower than 5 or higher than 17 mmHg at the end of follow-up after 2 years, the need for surgical revision, secondary glaucoma surgery, or loss of light perception. Outcome was rated as complete success or qualified success, depending on whether it was achieved with or without anti-glaucomatous medications. Postoperative complications and interventions were also documented for both groups. Results In the MicroShunt group, mean IOP decreased from 20.6 ± 7.5 mmHg at baseline to 13.0 ± 3.9 mmHg (p < 0.0001) after 2 years. In the XEN group, mean IOP was lowered from 22.5 ± 7.9 mmHg to 13.5 ± 4.2 mmHg (p < 0.0001). In both groups, the mean number of medications was significantly reduced (MicroShunt 2.7 ± 1.2 to 0.9 ± 2.5; p < 0.0001 vs. XEN 3.2 ± 0.9 to 1.1 ± 1.5; p < 0.0001). In regard to success rates, 37% of MicroShunt patients achieved complete success and 57% qualified success at the end of follow-up. In the XEN group, rates were 25 and 45%, respectively. Patient demographics differed between the two groups with respect to age (MicroShunt 72.8 ± 8.7 vs. XEN 67.7 ± 9.0 years; p = 0.002). Postoperative complications were comparable between the two groups. Conclusion Both MicroShunt and XEN are effective in significantly reducing IOP and glaucoma medications in OAG, and with a good safety profile.
1 September 2023 in MMW - Fortschritte der Medizin