Vidhya Maney Surendran

Dr. Vidhya Maney Surendran

Manipal School of Architecture and Planning, Manipal Academy of Higher Education, Manipal, India
+1
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Vidhya Maney SurendranVidhya Maney Surendran
Vidhya Maney Surendran
CICHANDRAMATHY IRULAPPAN
CHANDRAMATHY IRULAPPAN
VJVijayalaxmi Jeyasingh
Vijayalaxmi Jeyasingh
Velraj RamalingamVelraj Ramalingam
Velraj Ramalingam
This study aims to propose building envelope retrofit packages for existing naturally ventilated school buildings in the hot–humid climatic region of Chennai, India. Indoor thermal parameters were collected through field studies from nine sample classrooms of a selected school building in May 2019, between 9.00 am and 4.00 pm. The thermal performance assessment of the existing building was performed by examining the discomfort hours using the CBE thermal comfort tool. Envelope retrofit strategies gathered from the literature and building standards were applied and studied through simulation. The findings reveal the enormous potential to increase the thermal comfort of existing school buildings through envelope retrofit measures. The results demonstrate that the whole-building temperature can be reduced up to 3.2 °C in summer and up to 3.4 °C in winter. Implementing retrofit measures to the building envelopes of existing buildings will help school owners to increase the comfortable hours of whole buildings by up to 17%. In comparison, annual energy savings of up to 13% for the whole building can be made by enhancing the thermal performance of the building envelope. The findings will also help architects to optimise thermal performance and energy usage with minimal interventions.


10 July 2026 in ShodhSamajik: Journal of Social Studies
Verified
Journal Article
Open access
PDF file
NSNishi Sudesh Sukthankar
Nishi Sudesh Sukthankar
Vidhya Maney SurendranVidhya Maney Surendran
Vidhya Maney Surendran
NNN.S. Nalini
N.S. Nalini
RSRama R. Subrahmanian
Rama R. Subrahmanian
This study aims to evaluate the structural conditions, social perspectives, and adaptive reuse potential of two historic courtyard houses in Kavlem, Goa. The study adopts a mixed-methods approach, combining spatial documentation, stakeholder interviews, people's perceptual surveys, and expert consultations with structural engineers. On-site audits, plan analysis, and photographic documentation were used to analyze two case houses: Dubashi and Gaitonde. A reuse-readiness matrix was created, and intervention techniques were suggested based on condition, cultural alignment, and community feedback. Among the two century-old courtyard houses, the structurally sound Dubashi house is deemed suitable for limited cultural use after minor repairs as per all the surveyed architects and engineers. All interviewed respondents indicate that traditional Goan courtyard houses can be adapted with minimal intervention if done sensitively. In comparison, the more fragile Gaitonde home requires considerable structural restoration before usage, with 75% of specialists citing difficulties such as foundation erosion, timber rot, and roof instability as prevalent vulnerabilities that require major intervention. According to community surveys, 94% of respondents support the preservation of these properties, while 59% prefer adaptive reuse for culturally relevant, non-commercial activities such as museums, cultural art shows, or spiritual places.