Liang Guo

Prof. Liang Guo

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2013 in Science
Verified
Journal Article
Closed access
PDF file
MMMingming Ma
Mingming Ma
LGLiang Guo
Liang Guo
DADaniel G. Anderson
Daniel G. Anderson
RLRobert Langer
Robert Langer
Mini Mighty Muscle: Actuators—or artificial muscles—take electrical or chemical energy and convert it into mechanical force. Typically, actuators made from polymers can show large deformations, but cannot generate a lot of force.Maet al.(p.186; see the Perspective byKim and Kwon) describe a polymer composite based on a modified polypyrrole that expands in response to water absorption. The composite was able to generate large stresses and forces, and offered a high work density approaching those of the best conducting polymer electrochemical actuators. Magnetic nanoparticles incorporated into polymer films were used to control the locomotion of the actuator.

22 October 2013 in Advanced Materials
Verified
Journal Article
Open access
PDF file
LGLiang Guo
Liang Guo
MMMingming Ma
Mingming Ma
NZNing Zhang
Ning Zhang
RLRobert Langer
Robert Langer
DADaniel G. Anderson
Daniel G. Anderson
A highly stretchable neural interface of concurrent robust electrical and mechanical properties is developed with a conducting polymer film as the sole conductor for both the electrodes and the leads. This neural interface offers the benefits of conducting polymer electrodes in a demanding stretchable format, including low electrode impedance and high chargeinjection capacity, due to the large electroactive surface area of the electrode.

8 May 2012 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
LGLiang Guo
Liang Guo
GGGareth S. Guvanasen
Gareth S. Guvanasen
XLXi Liu
Xi Liu
CTChristopher Tuthill
Christopher Tuthill
TNT. Richard Nichols
T. Richard Nichols
SDStephen P. DeWeerth
Stephen P. DeWeerth
Numerous applications in neuroscience research and neural prosthetics, such as electrocorticogram (ECoG) recording and retinal prosthesis, involve electrical interactions with soft excitable tissues using a surface recording and/or stimulation approach. These applications require an interface that is capable of setting up high-throughput communications between the electrical circuit and the excitable tissue and that can dynamically conform to the shape of the soft tissue. Being a compliant material with mechanical impedance close to that of soft tissues, polydimethylsiloxane (PDMS) offers excellent potential as a substrate material for such neural interfaces. This paper describes an integrated technology for fabrication of PDMS-based stretchable microelectrode arrays (MEAs). Specifically, as an integral part of the fabrication process, a stretchable MEA is directly fabricated with a rigid substrate, such as a thin printed circuit board (PCB), through an innovative bonding technology-via-bonding-for integrated packaging. This integrated strategy overcomes the conventional challenge of high-density packaging for this type of stretchable electronics. Combined with a high-density interconnect technology developed previously, this stretchable MEA technology facilitates a high-resolution, high-density integrated system solution for neural and muscular surface interfacing. In this paper, this PDMS-based integrated stretchable MEA (isMEA) technology is demonstrated by an example design that packages a stretchable MEA with a small PCB. The resulting isMEA is assessed for its biocompatibility, surface conformability, electrode impedance spectrum, and capability to record muscle fiber activity when applied epimysially.

4 October 2007 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
KMKathleen W. Meacham
Kathleen W. Meacham
RGRichard J. Giuly
Richard J. Giuly
LGLiang Guo
Liang Guo
SHShawn Hochman
Shawn Hochman
SDStephen P. DeWeerth
Stephen P. DeWeerth

7 March 2016 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
YWYongchen Wang
Yongchen Wang
LGLiang Guo
Liang Guo
Neural stimulation is a critical technique in treating neurological diseases and investigating brain functions. Traditional electrical stimulation uses electrodes to directly create intervening electric fields in the immediate vicinity of neural tissues. Second-generation stimulation techniques directly use light, magnetic fields or ultrasound in a non-contact manner. An emerging generation of non- or minimally invasive neural stimulation techniques is enabled by nanotechnology to achieve a high spatial resolution and cell-type specificity. In these techniques, a nanomaterial converts a remotely transmitted primary stimulus such as a light, magnetic or ultrasonic signal to a localized secondary stimulus such as an electric field or heat to stimulate neurons. The ease of surface modification and bio-conjugation of nanomaterials facilitates cell-type-specific targeting, designated placement and highly localized membrane activation. This review focuses on nanomaterial-enabled neural stimulation techniques primarily involving opto-electric, opto-thermal, magneto-electric, magneto-thermal and acousto-electric transduction mechanisms. Stimulation techniques based on other possible transduction schemes and general consideration for these emerging neurotechnologies are also discussed.

17 August 2010 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
LGLiang Guo
Liang Guo
SDStephen P. DeWeerth
Stephen P. DeWeerth