Background: Virtual reality (VR) and augmented reality (AR) have recently become popular research themes. However, there are no published bibliometric reports that have analyzed the corresponding scientific literature in relation to the application of these technologies in medicine. Objective: We used a bibliometric approach to identify and analyze the scientific literature on VR and AR research in medicine, revealing the popular research topics, key authors, scientific institutions, countries, and journals. We further aimed to capture and describe the themes and medical conditions most commonly investigated by VR and AR research. Methods: The Web of Science electronic database was searched to identify relevant papers on VR research in medicine. Basic publication and citation data were acquired using the “Analyze” and “Create Citation Report” functions of the database. Complete bibliographic data were exported to VOSviewer and Bibliometrix, dedicated bibliometric software packages, for further analyses. Visualization maps were generated to illustrate the recurring keywords and words mentioned in the titles and abstracts. Results: The analysis was based on data from 8399 papers. Major research themes were diagnostic and surgical procedures, as well as rehabilitation. Commonly studied medical conditions were pain, stroke, anxiety, depression, fear, cancer, and neurodegenerative disorders. Overall, contributions to the literature were globally distributed with heaviest contributions from the United States and United Kingdom. Studies from more clinically related research areas such as surgery, psychology, neurosciences, and rehabilitation had higher average numbers of citations than studies from computer sciences and engineering. Conclusions: The conducted bibliometric analysis unequivocally reveals the versatile emerging applications of VR and AR in medicine. With the further maturation of the technology and improved accessibility in countries where VR and AR research is strong, we expect it to have a marked impact on clinical practice and in the life of patients.
Background: Human patient simulators and airway training manikins are widely used to train airway management skills to medical professionals. Furthermore, these patient simulators are employed as standardized "patients" to evaluate airway devices. However, little is known about how realistic these patient simulators and airway-training manikins really are. This trial aimed to evaluate the upper airway anatomy of four high-fidelity patient simulators and two airway trainers in comparison with actual patients by means of radiographic measurements. The volume of the pharyngeal airspace was the primary outcome parameter. Methods: Computed tomography scans of 20 adult trauma patients without head or neck injuries were compared with computed tomography scans of four high-fidelity patient simulators and two airway trainers. By using 14 predefined distances, two cross-sectional areas and three volume parameters of the upper airway, the manikins' similarity to a human patient was assessed. Results: The pharyngeal airspace of all manikins differed significantly from the patients' pharyngeal airspace. The HPS Human Patient Simulator (METI®, Sarasota, FL) was the most realistic high-fidelity patient simulator (6/19 [32%] of all parameters were within the 95% CI of human airway measurements). Conclusion: The airway anatomy of four high-fidelity patient simulators and two airway trainers does not reflect the upper airway anatomy of actual patients. This finding may impact airway training and confound comparative airway device studies.
Background: The aim of this study was to compare the effects of goal-directed colloid fluid therapy with goal-directed crystalloid and restricted crystalloid fluid therapy on healthy and perianastomotic colon tissue in a pig model of colon anastomosis surgery. Methods: Pigs (n = 27, 9 per group) were anesthetized and mechanically ventilated. A hand-sewn colon anastomosis was performed. The animals were subsequently randomized to one of the following treatments: R-RL group, 3 ml x kg(-1) x h(-1) Ringer lactate (RL); GD-RL group, 3 ml x kg(-1) x h(-1) RL + bolus 250 ml of RL; GD-C group, 3 ml x kg(-1) x h(-1) RL + bolus 250 ml of hydroxyethyl starch (HES 6%, 130/0.4). A fluid bolus was administered when mixed venous oxygen saturation dropped below 60%. Intestinal tissue oxygen tension and microcirculatory blood flow were measured continuously. Results: After 4 h of treatment, tissue oxygen tension in healthy colon increased to 150 +/- 31% in group GD-C versus 123 +/- 40% in group GD-RL versus 94 +/- 23% in group R-RL (percent of postoperative baseline values, mean +/- SD; P < 0.01). Similarly perianastomotic tissue oxygen tension increased to 245 +/- 93% in the GD-C group versus 147 +/- 58% in the GD-RL group and 116 +/- 22% in the R-RL group (P < 0.01). Microcirculatory flow was higher in group GD-C in healthy colon. Conclusions: Goal-directed colloid fluid therapy significantly increased microcirculatory blood flow and tissue oxygen tension in healthy and injured colon compared to goal-directed or restricted crystalloid fluid therapy.
Accurate measurement of core temperature is a standard component of perioperative and intensive care patient management. However, core temperature measurements are difficult to obtain in awake patients. A new non-invasive thermometer has been developed, combining two sensors separated by a known thermal resistance (‘double-sensor’ thermometer). We thus evaluated the accuracy of the double-sensor thermometer compared with a distal oesophageal thermometer to determine if the double-sensor thermometer is a suitable substitute. In perioperative and intensive care patient populations (n=68 total), double-sensor measurements were compared with measurements from a distal oesophageal thermometer using Bland–Altman analysis and Lin's concordance correlation coefficient (CCC). Overall, 1287 measurement pairs were obtained at 5 min intervals. Ninety-eight per cent of all double-sensor values were within ±0.5°C of oesophageal temperature. The mean bias between the methods was −0.08°C; the limits of agreement were −0.66°C to 0.50°C. Sensitivity and specificity for detection of fever were 0.86 and 0.97, respectively. Sensitivity and specificity for detection of hypothermia were 0.77 and 0.93, respectively. Lin's CCC was 0.93. The new double-sensor thermometer is sufficiently accurate to be considered an alternative to distal oesophageal core temperature measurement, and may be particularly useful in patients undergoing regional anaesthesia.