John-Peder Escobar Kvitting

Prof. John-Peder Escobar Kvitting

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2007 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Closed access
ABAnn Bolger
Ann Bolger
EHEinar Heiberg
Einar Heiberg
MKMatts Karlsson
Matts Karlsson
LWLars Wigström
Lars Wigström
JEJan Engvall
Jan Engvall
BWBengt Wranne
Bengt Wranne
The transit of blood through the beating heart is a basic aspect of cardiovascular physiology which remains incompletely studied. Quantification of the components of multidirectional flow in the normal left ventricle (LV) is lacking, making it difficult to put the changes observed with LV dysfunction and cardiac surgery into context. Three dimensional, three directional, time resolved magnetic resonance phase-contrast velocity mapping was performed at 1.5 Tesla in 17 normal subjects, 6 female, aged 44+/-14 years (mean+/-SD). We visualized and measured the relative volumes of LV flow components and the diastolic changes in inflowing kinetic energy (KE). Of total diastolic inflow volume, 44+/-11% followed a direct, albeit curved route to systolic ejection (videos 1 and 2), in contrast to 11% in a subject with mildly dilated cardiomyopathy (DCM), who was included for preliminary comparison (video 3). In normals, 16+/-8% of the KE of inflow was conserved to the end of diastole, compared with 5% in the DCM patient. Blood following the direct route lost or transferred less of its KE during diastole than blood that was retained until the next beat (1.6+/-1.0 millijoules vs 8.2+/-1.9 millijoules, p<0.05); whereas, in the DCM patient, the reduction in KE of retained inflow was 18-fold greater than that of the blood tracing the direct route. Multidimensional flow mapping can measure the paths, compartmentalization and kinetic energy changes of blood flowing into the LV, demonstrating differences of KE loss between compartments, and potentially between the flows in normal and dilated left ventricles.

6 September 2006 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
PDPetter Dyverfeldt
Petter Dyverfeldt
ASAndreas Sigfridsson
Andreas Sigfridsson
JKJohn-Peder Escobar Kvitting
John-Peder Escobar Kvitting
TETino Ebbers
Tino Ebbers
Turbulent flow, characterized by velocity fluctuations, is a contributing factor to the pathogenesis of several cardiovascular diseases. A clinical noninvasive tool for assessing turbulence is lacking, however. It is well known that the occurrence of multiple spin velocities within a voxel during the influence of a magnetic gradient moment causes signal loss in phase‐contrast magnetic resonance imaging (PC‐MRI). In this paper a mathematical derivation of an expression for computing the standard deviation (SD) of the blood flow velocity distribution within a voxel is presented. The SD is obtained from the magnitude of PC‐MRI signals acquired with different first gradient moments. By exploiting the relation between the SD and turbulence intensity (TI), this method allows for quantitative studies of turbulence. For validation, the TI in an in vitro flow phantom was quantified, and the results compared favorably with previously published laser Doppler anemometry (LDA) results. This method has the potential to become an important tool for the noninvasive assessment of turbulence in the arterial tree. Magn Reson Med, 2006.

5 September 2008 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
PDPetter Dyverfeldt
Petter Dyverfeldt
JKJohn-Peder Escobar Kvitting
John-Peder Escobar Kvitting
ASAndreas Sigfridsson
Andreas Sigfridsson
JEJan Engvall
Jan Engvall
ABAnn F. Bolger
Ann F. Bolger
TETino Ebbers
Tino Ebbers
Purpose: To evaluate the feasibility of generalized phase‐contrast magnetic resonance imaging (PC‐MRI) for the noninvasive assessment of fluctuating velocities in cardiovascular blood flow.Materials and Methods: Multidimensional PC‐MRI was used in a generalized manner to map mean flow velocities and intravoxel velocity standard deviation (IVSD) values in one healthy aorta and in three patients with different cardiovascular diseases. The acquired data were used to assess the kinetic energy of both the mean (MKE) and the fluctuating (TKE) velocity field.Results: In all of the subjects, both mean and fluctuating flow data were successfully acquired. The highest TKE values in the patients were found at sites characterized by abnormal flow conditions. No regional increase in TKE was found in the normal aorta.Conclusion: PC‐MRI IVSD mapping is able to detect flow abnormalities in a variety of human cardiovascular conditions and shows promise for the quantitative assessment of turbulence. This approach may assist in clarifying the role of disturbed hemodynamics in cardiovascular diseases. J. Magn. Reson. Imaging 2008;28:655–663.

1 January 2013 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
JKJohn-Peder Escobar Kvitting
John-Peder Escobar Kvitting
FKFabian A. Kari
Fabian A. Kari
MFMichael P. Fischbein
Michael P. Fischbein
DLDavid H. Liang
David H. Liang
ABAnne-Sophie Beraud
Anne-Sophie Beraud
DMD. Craig Miller
D. Craig Miller

1 September 1999 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
JKJohn-Peder Escobar Kvitting
John-Peder Escobar Kvitting
LWLars Wigström
Lars Wigström
JSJörg M. Strotmann
Jörg M. Strotmann
GSGeorge R. Sutherland
George R. Sutherland

19 February 2011 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MRManuel K. Rausch
Manuel K. Rausch
WBWolfgang Bothe
Wolfgang Bothe
JKJohn-Peder Escobar Kvitting
John-Peder Escobar Kvitting
JSJulia C. Swanson
Julia C. Swanson
NINeil B. Ingels
Neil B. Ingels
EKEllen Kuhl
Ellen Kuhl