Glenn O. Brown

Dr. Glenn O. Brown

Oklahoma State University
orcid
Regents Professor Emeritus

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2008 in Water Environment Research
Verified
Journal Article
Closed access
PDF file
WZWei Zhang
Wei Zhang
GBGlenn O. Brown
Glenn O. Brown
DSDaniel E. Storm
Daniel E. Storm
HZHailin Zhang
Hailin Zhang

29 September 2017 in Water
Verified
Journal Article
Open access
PDF file
SKSaroj Kandel
Saroj Kandel
JVJason Vogel
Jason Vogel
Chad PennChad Penn
Chad Penn
GBGlenn O. Brown
Glenn O. Brown
Bioretention cells (BRCs) have shown potential for storm water quantity and quality control. However, the phosphorus (P) removal in BRC has been variable due to differences of soil properties in filter media. The objectives of this research were to identify and evaluate P accumulation in filter media and to quantify effluent P reduction in BRC. Each cell has a sand and fly ash media designed to remove phosphorous. Filter media were collected in 2014 across the cell surface and to a depth of 0.6 m to quantify the P accumulation. The mean total P (T-P) concentration increased over the seven years of operation, but the changes were not statistically significant. The average Mehlich-3 P (M3-P) and water-soluble P (WS-P) concentrations in the media profiles showed higher P accumulation in the top 0.15 m. The average M3-P and WS-P concentrations between 0.15 m to 0.30 m, and 0.30 m to 0.60 m were variable on all four BRCs media. The media with 5% fly ash significantly retained M3-P and WS-P over the top 0.15 m. Stormwater influent and effluent samples from three of the BRCs monitored over one year showed reductions in both P concentration (68% to 75%) and P mass (76% to 93%).

16 May 2024 in Water
Verified
Journal Article
Open access
PDF file
JLJessica Lay
Jessica Lay
JVJason Vogel
Jason Vogel
JBJason Belden
Jason Belden
GBGlenn O. Brown
Glenn O. Brown
DSDaniel E. Storm
Daniel E. Storm
Rainwater runoff samples from a range of roofing materials were temporally collected from 19 small-scale roof structures and two commercial buildings through simulated and actual storm events, and the concentrations of polycyclic aromatic hydrocarbons (PAHs), phosphorus flame retardants (PFLs), and pyrethroid insecticides and other water quality parameters were analyzed. In Part I of this research, the concentrations of these contaminants in roof runoff and soils receiving runoff from a range of roofing materials were evaluated. In Part II, recommendations have been developed for a first-flush exclusion to improve the quality of water harvesting for nonpotable uses. Recommendations focus on a first-flush diversion based on mass removals of total suspended solids (TSS) and PAHs linked to conductivity measurements throughout a storm event. Additionally, an upper-confidence limit (UCL) was constructed to determine the minimum diversion required to obtain 50, 75, 90, and 95% mass removal of TSS and PAH contaminants. The majority of TSS were produced during the initial 1.2 mm of runoff. Likewise, the majority of PAHs were removed during the initial 1.2 mm of runoff, except for the asphalt shingle roofs, where high PAHs were observed after 6 mm of runoff. The Texas Water Development Board (TWDB)-recommended first-flush diversion of one gallon for every 100 square feet of rooftop was not always adequate for removing 50% of TSS and PAHs from the roofs. Rainwater runoff conductivity decreased drastically between 1.2 to 2.4 mm of rainwater runoff. Diverting the first flush based on conductivity has the potential to also divert the majority of TSS and PAHs in roof runoff.

15 July 2017 in Water
Verified
Journal Article
Open access
PDF file
SJSheila Youngblood Johnston
Sheila Youngblood Johnston
JVJason Vogel
Jason Vogel
GBGlenn O. Brown
Glenn O. Brown
DSDaniel Storm
Daniel Storm
AMAlex McLemore
Alex McLemore
SKSaroj Kandel
Saroj Kandel
Microbial pollution in stormwater is a concern in urban areas across the U.S. and is a leading cause of water-quality impairment in the United States. This issue may be addressed through the use of best management practices (BMPs) and target limits for pathogenic indicator species. Bioretention is a commonly used low impact development strategy that addresses this growing pollution problem at the source. Bioretention removal efficiencies have been well studied when considering nutrients and heavy metals, but field-scale treatment data are limited for microbial indicators. The primary objective of this study was to quantify microbial removal by installed bioretention cells with fly-ash amended soils. Three bioretention cells in Grove, Oklahoma were monitored over one and a half years and the removal microbial efficiency was quantified. Overall, removal rates for E. coli, enterococci, and coliphage were highly variable, with mean and standard deviations for removals for each site respectively: E. coli 87%, 35%, and 43%; enterococci 97%, 95%, and 80%; and coliphage 38%, 75%, and 32%. The site with negative removal efficiency appears to have some groundwater intrusion during storm events. Based on this relatively limited data set, these fly-ash amended bioretention cells performed 49% better than those with a sand-only filter media layer currently reported in the literature. Based on this initial field study, it appears that fly-ash amended bioretention cells may be a viable option for enhanced microbial removal from stormwater runoff.

5 October 2001
Verified
Conference Paper
Closed access
GBGlenn O. Brown
Glenn O. Brown
Starting in 1856 Henry Darcy, with the assistance of Henri Bazin, published four works that show various forms of an improved Pitot tube design. While Henri Pitot had invented the device in 1732, theoretical and design weaknesses had kept it little more than a scientific toy. Darcy's instruments provided accurate and easy measurements of point velocity for the first time. This allowed advances in open channel and pipe flow hydraulics. Darcy's final design for the instrument tip is reflected today in all of our modern instruments.

14 May 2024 in Water
Verified
Journal Article
Open access
PDF file
JLJessica Lay
Jessica Lay
JVJason Vogel
Jason Vogel
JBJason Belden
Jason Belden
GBGlenn O. Brown
Glenn O. Brown
DSDaniel E. Storm
Daniel E. Storm
Rainfall runoff may be captured and stored for later use, but the quality of this water can be detrimental in some uses without the use of appropriately designed first-flush diverters. The rainfall runoff water quality was measured on nineteen new small-scale and two aged commercial roofs located near high traffic highways. Roof coverings included asphalt shingles, sheet metal, clay tiles, and tar and gravel. Runoff samples were evaluated for polycyclic aromatic hydrocarbons (PAHs), phosphorus flame retardants (PFRs), and pyrethroid insecticides. Eighteen small-scale roofs were subjected to a range of simulated rainfall events, while natural runoff was sampled on the commercial roofs and one small-scale roof. Runoff was analyzed for pH, conductivity, turbidity, total suspended solids, boron, iron, copper, zinc, manganese, sodium adsorption ratio, nitrate-nitrogen, seventeen PAHs, tris(2-chloroethyl) phosphate, tris(1,3-dichloro-2-propyl)phosphate, bifenthrin, cypermethrin, and lambda-cyhalothrin. Samples from four natural storm events were also analyzed for total coliforms and Escherichia coli. In addition, soils below seventeen existing gutter downspouts were sampled to determine long-term pollutant accumulation. Atmospheric deposition was the main contributor of pollutants in the roof runoff. A majority of samples fell within the U.S. EPA guidelines for non-potable urban and agricultural water reuse. Trace levels of PAHs, PFRs, and insecticides were detected, but all detections were three orders of magnitude below the USGS health-based screening level benchmark concentrations. Results indicate that diverting the first flush, based on turbidity, total suspended solids, or conductivity, can improve the overall water quality and reduce the concentrations of PAHs in harvested rainwater. Downspout soil sampling showed potential for the long-term accumulation of PAHs at concentrations exceeding the minimum human-health risk-based screening levels at these high runoff-loading locations.